Skip to content

Latest commit

 

History

76 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Orcon MVS-15

(Work in progress)

Home-Assistant integration for the Orcon MVS-15 fan, (optional) remote with CO₂ sensor and (optional) RF15 remote.

Uses MQTT and a Ramses ESP stick to communicate with the fan.

I used ramses_rf and this wiki for some code/inspiration/help.

Features

  • Creates a fan entity with all supported presets (Away, Auto, Low, Medium, High + High 15/30/60m timed modes)
  • Auto-detects the fan
  • Auto-detects a CO₂ remote and creates an HA sensor
  • Auto-detects the fan's humidity sensor and creates an HA sensor
  • Creates a binary sensor that triggers when the fan reports a fault
  • The fan reported mode is used to update the fan's current preset in HA, so it will immediately notice when the mode was changed by an RF15 remote for example

TODO

  • Setup a fake remote and pair it with the fan
  • Ramses ESP stick via USB (currently only supports MQTT)

Install

You can install this integration by adding its Github repository to the HACS configuration under Custom repositories.

Auto-discovery

  1. Install and configure the integration
  2. Turn the fan off and on again
  3. The fan will be discovered by a startup message (042F) it sends out
  4. The state of the humidity sensor (part of the fan) will be requested (12A0), and will be setup in HA if it responds
  5. The CO₂ sensor/remote will be discovered as soon as it sends a vent demand message (31E0) to the above fan (might take a while)

Lovelace

type: tile
entity: fan.orcon_mvs_15_fan
show_entity_picture: false
hide_state: true
vertical: false
features_position: inline
features:
  - type: fan-preset-modes
    style: dropdown

Alert on fault

alert:
  orcon_mvs_15_fault:
    title: Orcon MVS-15 fault
    name: The fan reported a fault
    done_message: The fan fault was cleared
    entity_id: binary_sensor.orcon_mvs_15_fan_fault
    repeat: 1440
    notifiers:
      - persistent_notification  # create an alert in the web ui
      - mobile_app_your_phone  # send a notification through the companion app

Check the LED on the fan unit if it reports a fault:

Flashing red Error
1x Motor not running
2x No value from humidity sensor
3x RF communication failure

Supported Ramses II codes

The following codes are supported by the Orcon MVS-15 fan. Not all codes are used (yet) by the integration.

Code Description Used FAN CO₂ RF Broadcast interval Requestable Notes
042F Power cycle counter Yes Yes No No - No Send on powerup
10E0 Device info Yes Yes Yes No 24h Yes
10E1 Device ID No Yes Yes No - Yes
1298 CO₂ sensor Yes No Yes No 10m Yes
12A0 Indoor humidty Yes Yes No No - Yes
1FC9 RF Bind No ? ? - No
22F1 Fan mode Yes Yes No No - Yes
22F3 Fan mode with timer Yes Yes No No - No
31D9 Fan state Yes Yes No No 5m Yes Fan mode + fault flag
31E0 Vent demand Yes No Yes No 5m Yes

About

Home-Assistant integration for Orcon MVS-15 fan + 15RF co2 sensor

Resources

Stars

1 star

Watchers

2 watching

Forks

Releases

Packages

Contributors

Languages