What I did

add cpo els cli show
show interfaces transceiver eeprom -d
sfputil show eeprom -d

Which release branch to backport (provide reason below if selected)

  • 202305
  • 202311
  • 202405
  • 202411
  • 202505
  • 202511
  • 202605
  • 202608

How I did it

add cpo els key map

How to verify it

show interfaces transceiver eeprom -d
sfputil show eeprom -d
show interfaces transceiver status

Previous command output (if the output of a command-line utility has changed)

 root@sonic:/# show interfaces transceiver eeprom -d Ethernet0
 Ethernet0: SFP EEPROM detected
         Active Firmware: N/A
         Active application selected code assigned to host lane 1: 1
         Active application selected code assigned to host lane 2: 1
         Active application selected code assigned to host lane 3: 1
         Active application selected code assigned to host lane 4: 1
         Active application selected code assigned to host lane 5: 1
         Active application selected code assigned to host lane 6: 1
         Active application selected code assigned to host lane 7: 1
         Active application selected code assigned to host lane 8: 1
         Application Advertisement: 400GAUI-4-L C2M (Annex 120G) - Host Assign (0x11) - 400G-FR4/400GBASE-FR4 (Cl 151) - Media Assign (0x11)
                                    200GAUI-4 C2M (Annex 120E) - Host Assign (0x11) - 200GBASE-FR4 (Cl 122) - Media Assign (0x11)
                                    CAUI-4 C2M (Annex 83E) with RS(528,514) FEC - Host Assign (0x11) - 100G CWDM4 MSA Spec - Media Assign (0x11)
         CMIS Rev: 5.2
         Connector: LC
         Encoding: N/A
         Extended Identifier: Power Class 5 (8.0W Max)
         Extended RateSelect Compliance: N/A
         Host Lane Count: 4
         Identifier: CPO Bailly
         Inactive Firmware: N/A
         Length Cable Assembly(m): 0.0
         Media Interface Technology: Others
         Media Lane Count: 4
         Module Hardware Rev: 0.0
         Nominal Bit Rate(100Mbs): N/A
         Specification compliance: sm_media_interface
         Vendor Date Code(YYYY-MM-DD Lot): 20
         Vendor Name: BROADCOM
         Vendor OUI: ec-01-e2
         Vendor PN: BCM78909CPO
         Vendor Rev: A0
         Vendor SN: 
         is_replaceable: False
         type_abbrv_name: QSFP-DD
         vdm_supported: False
         ChannelMonitorValues:
                 RX1Power: -40.0dBm
                 RX2Power: -40.0dBm
                 RX3Power: -40.0dBm
                 RX4Power: -40.0dBm
                 RX5Power: -40.0dBm
                 RX6Power: -40.0dBm
                 RX7Power: -40.0dBm
                 RX8Power: -40.0dBm
                 TX1Bias: 0.004mA
                 TX1Power: -40.0dBm
                 TX2Bias: 0.004mA
                 TX2Power: -40.0dBm
                 TX3Bias: 0.004mA
                 TX3Power: -40.0dBm
                 TX4Bias: 0.004mA
                 TX4Power: -40.0dBm
                 TX5Bias: 0.004mA
                 TX5Power: -40.0dBm
                 TX6Bias: 0.004mA
                 TX6Power: -40.0dBm
                 TX7Bias: 0.004mA
                 TX7Power: -40.0dBm
                 TX8Bias: 0.004mA
                 TX8Power: -40.0dBm
         ChannelThresholdValues:
                 RxPowerHighAlarm  : 7.0dBm
                 RxPowerHighWarning: 4.0dBm
                 RxPowerLowAlarm   : -9.901dBm
                 RxPowerLowWarning : -5.901dBm
                 TxBiasHighAlarm   : 162.5mA
                 TxBiasHighWarning : 156.248mA
                 TxBiasLowAlarm    : 15.0mA
                 TxBiasLowWarning  : 20.0mA
                 TxPowerHighAlarm  : 7.0dBm
                 TxPowerHighWarning: 4.0dBm
                 TxPowerLowAlarm   : -6.899dBm
                 TxPowerLowWarning : -2.9dBm
         ModuleMonitorValues:
                 Temperature: 32.293C
                 Vcc: 3.298Volts
         ModuleThresholdValues:
                 TempHighAlarm  : 90.0C
                 TempHighWarning: 85.0C
                 TempLowAlarm   : -5.0C
                 TempLowWarning : 0.0C
                 VccHighAlarm   : 3.63Volts
                 VccHighWarning : 3.465Volts
                 VccLowAlarm    : 2.97Volts
                 VccLowWarning  : 3.135Volts

 root@sonic:/# show interfaces transceiver status Ethernet0
 Ethernet0: 
         CMIS State (SW): FAILED
         Tx fault flag on media lane 1: False
         Tx fault flag on media lane 2: False
         Tx fault flag on media lane 3: False
         Tx fault flag on media lane 4: False
         Tx fault flag on media lane 5: False
         Tx fault flag on media lane 6: False
         Tx fault flag on media lane 7: False
         Tx fault flag on media lane 8: False
         Rx loss of signal flag on media lane 1: True
         Rx loss of signal flag on media lane 2: True
         Rx loss of signal flag on media lane 3: True
         Rx loss of signal flag on media lane 4: True
         Rx loss of signal flag on media lane 5: True
         Rx loss of signal flag on media lane 6: True
         Rx loss of signal flag on media lane 7: True
         Rx loss of signal flag on media lane 8: True
         TX disable status on lane 1: True
         TX disable status on lane 2: True
         TX disable status on lane 3: True
         TX disable status on lane 4: True
         TX disable status on lane 5: True
         TX disable status on lane 6: True
         TX disable status on lane 7: True
         TX disable status on lane 8: True
         Disabled TX channels: 255
         Current module state: ModuleLowPwr
         Reason of entering the module fault state: No Fault detected
         Datapath firmware fault: False
         Module firmware fault: False
         Module state changed: False
         Data path state indicator on host lane 1: DataPathDeactivated
         Data path state indicator on host lane 2: DataPathDeactivated
         Data path state indicator on host lane 3: DataPathDeactivated
         Data path state indicator on host lane 4: DataPathDeactivated
         Data path state indicator on host lane 5: DataPathDeactivated
         Data path state indicator on host lane 6: DataPathDeactivated
         Data path state indicator on host lane 7: DataPathDeactivated
         Data path state indicator on host lane 8: DataPathDeactivated
         Tx output status on media lane 1: False
         Tx output status on media lane 2: False
         Tx output status on media lane 3: False
         Tx output status on media lane 4: False
         Tx output status on media lane 5: False
         Tx output status on media lane 6: False
         Tx output status on media lane 7: False
         Tx output status on media lane 8: False
         Rx output status on host lane 1: False
         Rx output status on host lane 2: False
         Rx output status on host lane 3: False
         Rx output status on host lane 4: False
         Rx output status on host lane 5: False
         Rx output status on host lane 6: False
         Rx output status on host lane 7: False
         Rx output status on host lane 8: False
         Tx loss of signal flag on host lane 1: False
         Tx loss of signal flag on host lane 2: False
         Tx loss of signal flag on host lane 3: False
         Tx loss of signal flag on host lane 4: False
         Tx loss of signal flag on host lane 5: False
         Tx loss of signal flag on host lane 6: False
         Tx loss of signal flag on host lane 7: False
         Tx loss of signal flag on host lane 8: False
         Tx clock and data recovery loss of lock on host lane 1: N/A
         Tx clock and data recovery loss of lock on host lane 2: N/A
         Tx clock and data recovery loss of lock on host lane 3: N/A
         Tx clock and data recovery loss of lock on host lane 4: N/A
         Tx clock and data recovery loss of lock on host lane 5: N/A
         Tx clock and data recovery loss of lock on host lane 6: N/A
         Tx clock and data recovery loss of lock on host lane 7: N/A
         Tx clock and data recovery loss of lock on host lane 8: N/A
         Rx clock and data recovery loss of lock on media lane 1: False
         Rx clock and data recovery loss of lock on media lane 2: False
         Rx clock and data recovery loss of lock on media lane 3: False
         Rx clock and data recovery loss of lock on media lane 4: False
         Rx clock and data recovery loss of lock on media lane 5: False
         Rx clock and data recovery loss of lock on media lane 6: False
         Rx clock and data recovery loss of lock on media lane 7: False
         Rx clock and data recovery loss of lock on media lane 8: False
         Configuration status for the data path of host line 1: ConfigUndefined
         Configuration status for the data path of host line 2: ConfigUndefined
         Configuration status for the data path of host line 3: ConfigUndefined
         Configuration status for the data path of host line 4: ConfigUndefined
         Configuration status for the data path of host line 5: ConfigUndefined
         Configuration status for the data path of host line 6: ConfigUndefined
         Configuration status for the data path of host line 7: ConfigUndefined
         Configuration status for the data path of host line 8: ConfigUndefined
         Data path configuration updated on host lane 1: True
         Data path configuration updated on host lane 2: True
         Data path configuration updated on host lane 3: True
         Data path configuration updated on host lane 4: True
         Data path configuration updated on host lane 5: True
         Data path configuration updated on host lane 6: True
         Data path configuration updated on host lane 7: True
         Data path configuration updated on host lane 8: True
         Temperature high alarm flag: False
         Temperature high warning flag: False
         Temperature low warning flag: False
         Temperature low alarm flag: False
         Vcc high alarm flag: False
         Vcc high warning flag: False
         Vcc low warning flag: False
         Vcc low alarm flag: False
         Tx power high alarm flag on lane 1: False
         Tx power high alarm flag on lane 2: False
         Tx power high alarm flag on lane 3: False
         Tx power high alarm flag on lane 4: False
         Tx power high alarm flag on lane 5: False
         Tx power high alarm flag on lane 6: False
         Tx power high alarm flag on lane 7: False
         Tx power high alarm flag on lane 8: False
         Tx power high warning flag on lane 1: False
         Tx power high warning flag on lane 2: False
         Tx power high warning flag on lane 3: False
         Tx power high warning flag on lane 4: False
         Tx power high warning flag on lane 5: False
         Tx power high warning flag on lane 6: False
         Tx power high warning flag on lane 7: False
         Tx power high warning flag on lane 8: False
         Tx power low warning flag on lane 1: False
         Tx power low warning flag on lane 2: False
         Tx power low warning flag on lane 3: False
         Tx power low warning flag on lane 4: False
         Tx power low warning flag on lane 5: False
         Tx power low warning flag on lane 6: False
         Tx power low warning flag on lane 7: False
         Tx power low warning flag on lane 8: False
         Tx power low alarm flag on lane 1: False
         Tx power low alarm flag on lane 2: False
         Tx power low alarm flag on lane 3: False
         Tx power low alarm flag on lane 4: False
         Tx power low alarm flag on lane 5: False
         Tx power low alarm flag on lane 6: False
         Tx power low alarm flag on lane 7: False
         Tx power low alarm flag on lane 8: False
         Rx power high alarm flag on lane 1: False
         Rx power high alarm flag on lane 2: False
         Rx power high alarm flag on lane 3: False
         Rx power high alarm flag on lane 4: False
         Rx power high alarm flag on lane 5: False
         Rx power high alarm flag on lane 6: False
         Rx power high alarm flag on lane 7: False
         Rx power high alarm flag on lane 8: False
         Rx power high warning flag on lane 1: False
         Rx power high warning flag on lane 2: False
         Rx power high warning flag on lane 3: False
         Rx power high warning flag on lane 4: False
         Rx power high warning flag on lane 5: False
         Rx power high warning flag on lane 6: False
         Rx power high warning flag on lane 7: False
         Rx power high warning flag on lane 8: False
         Rx power low warning flag on lane 1: False
         Rx power low warning flag on lane 2: False
         Rx power low warning flag on lane 3: False
         Rx power low warning flag on lane 4: False
         Rx power low warning flag on lane 5: False
         Rx power low warning flag on lane 6: False
         Rx power low warning flag on lane 7: False
         Rx power low warning flag on lane 8: False
         Rx power low alarm flag on lane 1: False
         Rx power low alarm flag on lane 2: False
         Rx power low alarm flag on lane 3: False
         Rx power low alarm flag on lane 4: False
         Rx power low alarm flag on lane 5: False
         Rx power low alarm flag on lane 6: False
         Rx power low alarm flag on lane 7: False
         Rx power low alarm flag on lane 8: False
         Tx bias high alarm flag on lane 1: False
         Tx bias high alarm flag on lane 2: False
         Tx bias high alarm flag on lane 3: False
         Tx bias high alarm flag on lane 4: False
         Tx bias high alarm flag on lane 5: False
         Tx bias high alarm flag on lane 6: False
         Tx bias high alarm flag on lane 7: False
         Tx bias high alarm flag on lane 8: False
         Tx bias high warning flag on lane 1: False
         Tx bias high warning flag on lane 2: False
         Tx bias high warning flag on lane 3: False
         Tx bias high warning flag on lane 4: False
         Tx bias high warning flag on lane 5: False
         Tx bias high warning flag on lane 6: False
         Tx bias high warning flag on lane 7: False
         Tx bias high warning flag on lane 8: False
         Tx bias low warning flag on lane 1: False
         Tx bias low warning flag on lane 2: False
         Tx bias low warning flag on lane 3: False
         Tx bias low warning flag on lane 4: False
         Tx bias low warning flag on lane 5: False
         Tx bias low warning flag on lane 6: False
         Tx bias low warning flag on lane 7: False
         Tx bias low warning flag on lane 8: False
         Tx bias low alarm flag on lane 1: False
         Tx bias low alarm flag on lane 2: False
         Tx bias low alarm flag on lane 3: False
         Tx bias low alarm flag on lane 4: False
         Tx bias low alarm flag on lane 5: False
         Tx bias low alarm flag on lane 6: False
         Tx bias low alarm flag on lane 7: False
         Tx bias low alarm flag on lane 8: False

New command output (if the output of a command-line utility has changed)

root@sonic:/# show interfaces transceiver eeprom -d Ethernet0
Ethernet0: SFP EEPROM detected
Active Firmware: N/A
Active application selected code assigned to host lane 1: 1
Active application selected code assigned to host lane 2: 1
Active application selected code assigned to host lane 3: 1
Active application selected code assigned to host lane 4: 1
Active application selected code assigned to host lane 5: 1
Active application selected code assigned to host lane 6: 1
Active application selected code assigned to host lane 7: 1
Active application selected code assigned to host lane 8: 1
Application Advertisement: 400GAUI-4-L C2M (Annex 120G) - Host Assign (0x11) - 400G-FR4/400GBASE-FR4 (Cl 151) - Media Assign (0x11)
200GAUI-4 C2M (Annex 120E) - Host Assign (0x11) - 200GBASE-FR4 (Cl 122) - Media Assign (0x11)
CAUI-4 C2M (Annex 83E) with RS(528,514) FEC - Host Assign (0x11) - 100G CWDM4 MSA Spec - Media Assign (0x11)
CMIS Rev: 5.2
Connector: LC
ELS Identifier: QSFP-DD Double Density 8X Pluggable Transceiver
ELS Laser Count: 8
ELS Maximum Power Consumption: 12.0
ELS Revision: 0.1
ELS Vendor Date Code(YYYY-MM-DD Lot): 2023-12-01
ELS Vendor Name: BROADCOM
ELS Vendor OUI: ec-01-e2
ELS Vendor PN: ARLM-96F8DMZ
ELS Vendor Rev: A0
ELS Vendor SN: FD2342VG04W

Encoding: N/A
Extended Identifier: Power Class 5 (8.0W Max)
Extended RateSelect Compliance: N/A
Host Lane Count: 4
Identifier: CPO Bailly
Inactive Firmware: N/A
Length Cable Assembly(m): 0.0
Media Interface Technology: Others
Media Lane Count: 4
Module Hardware Rev: 0.0
Nominal Bit Rate(100Mbs): N/A
RLM Laser Lpower Mode Control: 0
RLM Laser Wavelength Grid: CWDM4

Specification compliance: sm_media_interface
Vendor Date Code(YYYY-MM-DD Lot): 20
Vendor Name: BROADCOM
Vendor OUI: ec-01-e2
Vendor PN: BCM78909CPO
Vendor Rev: A0
Vendor SN:
is_replaceable: False
type_abbrv_name: QSFP-DD
vdm_supported: False
ChannelMonitorValues:
RX1Power: -40.0dBm
RX2Power: -40.0dBm
RX3Power: -40.0dBm
RX4Power: -40.0dBm
RX5Power: -40.0dBm
RX6Power: -40.0dBm
RX7Power: -40.0dBm
RX8Power: -40.0dBm
TX1Bias: 0.004mA
TX1Power: -40.0dBm
TX2Bias: 0.004mA
TX2Power: -40.0dBm
TX3Bias: 0.004mA
TX3Power: -40.0dBm
TX4Bias: 0.004mA
TX4Power: -40.0dBm
TX5Bias: 0.004mA
TX5Power: -40.0dBm
TX6Bias: 0.004mA
TX6Power: -40.0dBm
TX7Bias: 0.004mA
TX7Power: -40.0dBm
TX8Bias: 0.004mA
TX8Power: -40.0dBm
ChannelThresholdValues:
RxPowerHighAlarm : 7.0dBm
RxPowerHighWarning: 4.0dBm
RxPowerLowAlarm : -9.901dBm
RxPowerLowWarning : -5.901dBm
TxBiasHighAlarm : 162.5mA
TxBiasHighWarning : 156.248mA
TxBiasLowAlarm : 15.0mA
TxBiasLowWarning : 20.0mA
TxPowerHighAlarm : 7.0dBm
TxPowerHighWarning: 4.0dBm
TxPowerLowAlarm : -6.899dBm
TxPowerLowWarning : -2.9dBm
ModuleMonitorValues:
Temperature: 32.293C
Vcc: 3.298Volts
ModuleThresholdValues:
TempHighAlarm : 90.0C
TempHighWarning: 85.0C
TempLowAlarm : -5.0C
TempLowWarning : 0.0C
VccHighAlarm : 3.63Volts
VccHighWarning : 3.465Volts
VccLowAlarm : 2.97Volts
VccLowWarning : 3.135Volts
ELSMonitorValues:
RLM0_Laser4_current: 0.0 mA
RLM0_Laser4_power: 0.010 mW -20.000 dBm
RLM0_Laser5_current: 0.0 mA
RLM0_Laser5_power: 0.140 mW -8.539 dBm
RLM0_Laser6_current: 0.0 mA
RLM0_Laser6_power: 0.010 mW -20.000 dBm
RLM0_Laser7_current: 0.0 mA
RLM0_Laser7_power: 0.010 mW -20.000 dBm
ELS Temperature: 15.957C
ELS Vcc: 3.384Volts
ELSThresholdValues:
ELS TempHighAlarm: 0.0C
ELS TempHighWarning: 0.0C
ELS TempLowAlarm: 0.0C
ELS TempLowWarning: 0.0C
ELS TxBiasHighAlarm: 0.0mA
ELS TxBiasHighWarning: 0.0mA
ELS TxPowerHighAlarm: 0.0mW
ELS TxPowerHighWarning: 0.0mW
ELS TxPowerLowAlarm: 0.0mW
ELS TxPowerLowWarning: 0.0mW
ELS VccHighAlarm: 0.0Volts
ELS VccHighWarning: 0.0Volts
ELS VccLowAlarm: 0.0Volts
ELS VccLowWarning: 0.0Volts

root@sonic:/# show interfaces transceiver status Ethernet0
... (Omit the original print output.)
ELS temperature high alarm flag: False
ELS temperature low alarm flag: False
ELS temperature high warning flag: False
ELS temperature low warning flag: False
ELS Vcc high alarm flag: False
ELS Vcc low alarm flag: False
ELS Vcc high warning flag: False
ELS Vcc low warning flag: False
ELS module state: Low power mode
ELS interrupt status: Interrupt event occurred

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

Hi, there are workflow run(s) waiting for approval, you may be first-time contributor. I will notify maintainers to help approve once PR is approved. Thanks!

---Powered by SONiC BuildBot

Comment thread scripts/sfpshow Outdated
@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

Comment thread sfputil/main.py Outdated
@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@KroosMicas KroosMicas changed the title add cpo bailly rlm cli show add cpo els cli show Jul 7, 2026
@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@prgeor prgeor left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

@KroosMicas please add a new section in the cli doc:-

https://github.com/sonic-net/sonic-utilities/blob/master/doc/Command-Reference.md

for the ELSP dom.

@prgeor

prgeor commented Jul 8, 2026

Copy link
Copy Markdown
Contributor

What I did

add cpo els cli show show interfaces transceiver eeprom -d sfputil show eeprom -d

How I did it

add cpo els key map

How to verify it

show interfaces transceiver eeprom -d sfputil show eeprom -d show interfaces transceiver status

Previous command output (if the output of a command-line utility has changed)

New command output (if the output of a command-line utility has changed)

@KroosMicas please add the new output for els

Signed-off-by: Griffin Gao <griffin@micasnetworks.com>
@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@KroosMicas KroosMicas closed this Jul 9, 2026
@KroosMicas

Copy link
Copy Markdown
Contributor Author

@KroosMicas please add a new section in the cli doc:-

https://github.com/sonic-net/sonic-utilities/blob/master/doc/Command-Reference.md

for the ELSP dom.

@prgeor Revisions completed.

@KroosMicas

Copy link
Copy Markdown
Contributor Author

What I did

add cpo els cli show show interfaces transceiver eeprom -d sfputil show eeprom -d

How I did it

add cpo els key map

How to verify it

show interfaces transceiver eeprom -d sfputil show eeprom -d show interfaces transceiver status

Previous command output (if the output of a command-line utility has changed)

New command output (if the output of a command-line utility has changed)

@KroosMicas please add the new output for els

Revisions completed.

@KroosMicas KroosMicas reopened this Jul 9, 2026
@mssonicbld

Copy link
Copy Markdown
Collaborator

/azp run

@azure-pipelines

Copy link
Copy Markdown
Azure Pipelines successfully started running 1 pipeline(s).

@micas-net micas-net left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LGTM!

Comment thread sfputil/main.py
@prgeor
prgeor merged commit 1b5a290 into sonic-net:master Jul 13, 2026
10 checks passed
KroosMicas added a commit to KroosMicas/sonic-utilities that referenced this pull request Jul 21, 2026
Signed-off-by: Griffin Gao <griffin@micasnetworks.com>
@mssonicbld

Copy link
Copy Markdown
Collaborator

This PR has backport request for branch(es): 202605,202608.
Added label(s) for branch(es) 202605,msft-202608.

---Powered by SONiC BuildBot

@mssonicbld

Copy link
Copy Markdown
Collaborator

This PR has backport request label(s) for branch(es): 202605,msft-202608, but is missing required test information. Please make sure you tick the tested branch(es) in the Tested branch section and provide test evidence (e.g., 202605: <test result>) in the Test result section as well in your PR description.

---Powered by SONiC BuildBot

@mssonicbld

Copy link
Copy Markdown
Collaborator

Cherry-pick PR to msft-202608: Azure/sonic-utilities.msft#421

rameshraghupathy pushed a commit to rameshraghupathy/sonic-utilities that referenced this pull request Jul 29, 2026
Signed-off-by: Griffin Gao <griffin@micasnetworks.com>
Signed-off-by: Ramesh Raghupathy <ram@cisco.com>
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Projects

None yet

Development

Successfully merging this pull request may close these issues.

7 participants