units::resolve now returns GeometryResult and refuses instead of assuming metres:

  • no IfcProject / UnitsInContext / LENGTHUNIT -> LengthUnitUndeclared
  • unreadable length or angle unit -> UnitUnreadable (unknown prefix, SI unit not METRE/RADIAN, context-dependent or offset unit, non-numeric factor)
  • two projects or two units of one kind -> UnitsAmbiguous
  • a missing PLANEANGLEUNIT refuses only where an angle is read (AngleUnitUndeclared); angle_to_radians is Option
  • UnitScale::Default removed; UnitScale::SI is explicit
  • conversion-based units now apply their UnitComponent (inch as 25.4 MILLI METRE was read as 25.4 m)

Facade: a model whose units do not resolve refuses every product with that error; bindings map it to invalid-model.

Breaking: ifc-geometry 0.32.0, openbim-ifc 0.39.0 at release.

Closes #585

Four typed refusals for a model whose units have no usable scale (#585).
IFC defines no default length or plane angle unit and UnitsInContext is
optional on IfcContext in IFC4, so resolve assumed a scale the file never
stated. resolve now returns a typed refusal; a missing angle unit is
refused only where an angle is read. IfcMeasureWithUnit values are read in
their UnitComponent; unknown SI prefixes and misnamed SI units are refused.
UnitScale::default is replaced by UnitScale::SI. Refs #585.
…units

Product geometry entry points carry the unit refusal on every requested
product instead of placing the model in metres. Refs #585.
Models and fixtures that declare no units read in UnitScale::SI or through
tests/support/assume_units.rs; the committed fixtures are unchanged. Adds the
#585 repro and reworks units_on_fixtures to count resolved and refused
fixtures.
error.rs crossed the 800-line limit with the unit refusals.
Inline models state a metre and a radian; a model without a length unit
refuses each product's placement with invalid-model. Refs #585.
AlignmentUnits::angle_to_radians is optional. A StartDirection without a
plane-angle unit refuses with AngleUnitUndeclared; length-only bridges
(linear placements, seam tolerance) no longer need one. ifc-geometry maps
the refusal back to GeometryError::AngleUnitUndeclared.
…eferred

A Cartesian-preferred conic trim with a point needs no plane-angle unit.
…ansform

world_transform resolves the project units first so a model without units
reports LengthUnitUndeclared. The fixture corpus test asserts lower bounds.
@GeneralPawz
GeneralPawz merged commit caa2350 into main Oct 28, 2026
22 checks passed
@GeneralPawz
GeneralPawz deleted the fix/585-units branch October 28, 2026 19:49