PowerClimate

HACS Integration

Install via HACS (recommended): Add this repository to HACS → Integrations → Custom repositories, set Category to Integration, then install and restart Home Assistant.

Audit Log

  • 0.2 — First public version
  • 0.3-beta — Improved config flow and optional water heat pump
  • 0.4.0-beta — Modularized core logic, assist control, solar power budgets, and formatting utilities
  • 0.5-beta — Separated mirror thermostats
  • 0.6.0 — Persistent timer state, refactored config flow, cleaned up codebase

Home Assistant custom integration to manage multiple heat-pump climate devices and coordinate their setpoints using per-device temperature offsets. and coordinate their setpoints using per-device temperature offsets.

Not affiliated with Home Assistant.

Features

  • Multi-heatpump orchestration: One virtual thermostat coordinates one optional water-based heat pump and any number of air-based assist heat pumps.

PowerClimate dashboard climate device: Home Assistant UI showing the PowerClimate virtual thermostat with current temperature, setpoint, and mode controls.

  • Per-device offsets + guardrails: Lower/upper offsets per device, plus global min/max setpoint limits.
  • Manual assists (default) + optional auto on/off: You decide when assists run, or let PowerClimate manage assist HVAC mode with timers and anti-short-cycle.
  • Power-aware control (optional): Solar preset can allocate per-device power budgets from a signed house net power sensor.
  • Thermostat mirroring: Optionally mirror setpoint changes only from selected thermostats into PowerClimate; thermostat HVAC on/off state is ignored.
  • Diagnostics: Thermal summary, per-HP behavior, derivatives, total power, and budget diagnostics.
  • Works with standard HA services: Orchestrates existing climate.* entities via Home Assistant.

Config air warmtepomp

Documentation

Installation

HACS (recommended)

  1. In Home Assistant, open HACS → Integrations → Custom repositories.
  2. Add the repository URL and set Category to Integration.
  3. Search for PowerClimate and install it.
  4. Restart Home Assistant.

Manual

Copy custom_components/powerclimate/ into your Home Assistant config/custom_components/ and restart Home Assistant.

Setup

  1. Home Assistant → Settings → Devices & Services → Add Integration → PowerClimate.

  2. Select one or more room temperature sensors (PowerClimate uses an average of available values).

  3. Select thermostats that PowerClimate should mirror (optional). Only setpoint changes on these thermostats are copied to PowerClimate; turning a mirrored thermostat off does not turn PowerClimate off.

  4. Select an optional water-based heat pump (0 or 1) and zero or more air-based assist heat pumps. The first mirrored thermostat is preselected for the water heat pump. Select heat pumps configuration

  5. Configure each selected device on its own page (role, sensors, offsets, and optional on/off control for assists).

Note: Set the lower setpoint offset so that the heat pump almost, but not completely, switches off. In this example, the setpoint will be a minimum of 17 °C when the heat pump itself measures 20 °C.

Config air warmtepomp

Support

  • Issues and feature requests: use the GitHub issue tracker linked in the integration manifest.

Control Algorithm

Water-based heat pump (optional)

  • If configured, PowerClimate owns the HVAC mode for the water-based device: it is forced to HEAT while the virtual climate entity is on and explicitly switched to OFF when PowerClimate is turned off.
  • The PowerClimate target temperature is clamped between the lower/upper offsets (and the global 16–30 °C limits) before being sent to the water-based device.
  • Water temperature is tracked and exposed via diagnostics (when a water sensor is configured).

Air-based assist heat pumps (0..n)

  • The user controls each assist pump's HVAC mode. When an assist is off, PowerClimate leaves it untouched.
  • When an assist pump is on, PowerClimate compares the room temperature to the requested target:
    • Minimal mode (room ≥ target): setpoint = current temp + lower offset.
    • Setpoint mode (room < target): setpoint = requested target clamped between current + lower offset and current + upper offset.
  • All temperatures are clamped between the global min/max before sending commands, ensuring thermostats stay in a safe operating window.

Preset Behavior

PowerClimate presets control how heat pumps operate in different scenarios:

Preset 💧 Water Heat Pump 🌬️ Air Heat Pump(s)
none Normal operation (HEAT mode, follows setpoint) Setpoint-tracking if ON, untouched if OFF
boost Boost mode (current + upper offset) Boost mode (current + upper offset)
Away Minimal mode (let temp drop to 16°C) OFF (if allow_on_off enabled), otherwise minimal
Solar Power-budgeted setpoint (uses surplus energy) Power-budgeted setpoint (priority after water HP)

Note: Solar preset requires a configured house net power sensor. Budget allocation prioritizes the water-based device first; any remaining air-device budget rotates across assists to avoid starving the same device every cycle. Away preset turns off air heat pumps only when allow_on_off_control is enabled for that device. Mirrored thermostat HVAC mode changes are not propagated; only temperature setpoint changes are mirrored.

Configuration Constants

All control parameters are defined in const.py and can be adjusted:

Constant Default Description
DEFAULT_MIN_SETPOINT 16.0 Absolute minimum temperature that will ever be sent to a pump.
DEFAULT_MAX_SETPOINT 30.0 Absolute maximum temperature sent to any pump.
DEFAULT_LOWER_SETPOINT_OFFSET_HP1 -0.3 HP1 minimal-mode offset relative to its own sensed temperature.
DEFAULT_UPPER_SETPOINT_OFFSET_HP1 1.5 HP1 ceiling offset relative to its sensed temperature.
DEFAULT_LOWER_SETPOINT_OFFSET_ASSIST -4.0 Assist minimal-mode offset (room satisfied).
DEFAULT_UPPER_SETPOINT_OFFSET_ASSIST 4.0 Assist ceiling offset when chasing the room setpoint.

Sensors

Sensors are added only for pumps that have a configured climate_entity_id.

Sensor Description
Temperature Derivative Room temperature change rate (°C/hour)
Water Derivative Water temperature change rate (°C/hour)
Thermal Summary Human-readable system state
HP1 Behavior HVAC status, temps, water temperature when available
HP2+ Behavior HVAC status, temps, and PowerClimate mode for each configured assist pump
Total Power Aggregated power from all configured pumps
Power Budget Allocated budget totals + per-device budgets (when enabled)

Behavior sensors are created for every configured pump, not only the first five.

Derivatives use the slope between the oldest and newest sample within the window (room: 15 minutes, water: 10 minutes), matching Home Assistant's Derivative helper behavior.

Behavior sensors label each pump as <first word> (hpX) to match the Thermal Summary format.

Heat Pump Tips

General setup guidance (always double-check your device manual):

  • Assist pumps (HP2–HP5): enable the manufacturer’s “heat shift” / °C offset if available to stabilize minimal mode, then tune lower_setpoint_offset accordingly so assists idle gently when the room is satisfied.
  • Water/hybrid pump (HP1): if hybrid, disable gas for space heating and cap CH/flow temperature around 45°C initially for better COP; adjust based on insulation and emitters.

Next Steps

  • Use Advanced options to tune assist thresholds (ETA in minutes) and anti-short-cycle
  • Use energy sensors or COP data for economic decisions
  • Add unit tests for the assist logic