@HK-Moebius

Copy link
Copy Markdown
Contributor

Mainsail: show chamber temperature and a compact ETA

Follow-up to #1042, as suggested by @KodeStar in #1042 (comment): instead of a separate MainsailHT90 tile, this extends the existing Mainsail enhanced app so every Klipper printer with a chamber sensor gets it.

Changes

Chamber temperature (only if the printer has one)

  • Klipper has no dedicated chamber object, so the app picks the first sensor with "chamber" in its name (case-insensitive) from heaters.available_sensors, in this order: heater_generic, temperature_sensor, temperature_fan, then any other object. The last step covers printer-specific objects like heater_chamber on the Prusa Pro HT90 (its sensors: heater_bed, heater_generic panel, heater_chamber, extruder). Because available_sensors only lists temperature objects, macros or fans named "chamber" can't match.
  • The sensor list comes from heaters=available_sensors, added to the existing printer/objects/query request. A second query for the temperature only happens when a chamber sensor exists.
  • Printers without a chamber sensor make the same number of requests as before and the tile looks unchanged.
  • Shown in every state (standby, printing, complete …), so you can see the chamber heat up or cool down.

ETA

  • The remaining time is shown as 2h 05min instead of Carbon's diffForHumans() ("2 hours from now"). The label changes from "Finish" to "ETA".
  • Below one minute, or when the estimate is already exceeded: Soon!. Without any estimate: N/A, as before.
  • The calculation is unchanged from Fix Mainsail livestats: wrong progress percentage and remaining time #1041 (slicer estimate from the file metadata minus print_duration, otherwise extrapolated from progress).

Testing

  • php -l and PHPCS PSR12 (same settings as the lint workflow) pass, and so does node testRunner.js.
  • On a real Prusa Pro HT90, both requests the app makes return the expected data: heaters=available_sensors lists heater_chamber, and heater_chamber=temperature returns 16.79, so the tile shows Chamber 17°C.
  • Ran livestats() and the blade template against mocked Moonraker responses, including the real HT90 sensor list above:
Case Tile
HT90 (heater_chamber), printing Complete 40% · ETA 2h 05min · Chamber 55°C
HT90 (heater_chamber), standby State Standby · Chamber 38°C
heater_generic chamber + temperature_sensor chamber_top heater_generic is used
No chamber sensor, printing Complete 25% · ETA 1h 30min (as before, new ETA format)
No chamber sensor, standby State Standby (unchanged, no extra request)
< 1 min left / estimate exceeded ETA Soon!

🤖 Generated with Claude Code

- Show the chamber temperature when the printer reports a heater or
  sensor with "chamber" in its name: heater_generic, temperature_sensor
  and temperature_fan first, then printer-specific objects such as
  heater_chamber on the Prusa Pro HT90. Sensors come from
  heaters.available_sensors in the existing query, so printers without
  a chamber make no extra request and look as before.
- Show the remaining time as "2h 05min" instead of "2 hours from now",
  "Soon!" below one minute.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>