EVPN-VXLAN Data Center Fabric - NetDevOps Lab

CI Latest release

A Juniper EVPN-VXLAN fabric built end-to-end as code: NetBox is the source of truth, Nornir renders Junos configs from it, Batfish validates them offline, NAPALM commits behind a two-layer rollback (inner liveness gate + outer marker walk), smoke tests gate the deploy, and SuzieQ watches for drift afterwards. Every change goes through CI before it reaches a device, and every deploy can be reverted automatically when smoke or drift fails.

What works today

  • EVPN-VXLAN fabric running on containerlab with vJunos-switch (EX9214 model). 2 spines, 2 leaves, 4 hosts. Full-mesh underlay, EVPN overlay, VLAN-aware MAC-VRF, anycast gateways on IRB, ESI-LAG dual-homing.
  • NetBox-driven configs: device data, VRFs, VLANs, VNIs, cabling, anycast MACs, RT scheme. populate.py is idempotent. Nornir's enrich_from_netbox() collects it all into a pydantic-validated HostData per device.
  • Render -> diff -> guard pipeline: Jinja2 templates produce per-device configs, byte-diffed against checked-in golden files, then scanned for placeholders / malformed password hashes before any NAPALM call.
  • Batfish validation: 7 offline checks (BGP topology, undefined references, parse status, IP ownership conflicts, ...) plus differential analysis vs main. PR-time CI posts the diff as a markdown PR comment via a batfish/allinone service container, with find-or-update so re-runs replace the comment instead of stacking.
  • Two-layer rollback on the deploy path. Inner gate: commit confirmed 120 + 30 s settle + per-host liveness check + napalm_confirm_commit; if any host loses SSH the confirm is skipped and Junos auto-rolls back at the deadline. Outer gate: every deploy commit carries a unique marker as the Junos commit comment, so deploy.py --rollback-marker $MARKER can walk show system commit per device and revert to pre-deploy state even after smoke's mid-run failover commits.
  • 76-check smoke suite runs after every commit (control plane, data plane, ESI failover, core isolation, spine failover, EVPN type 2/3/5 routes, ECMP, jumbo MTU). Roughly 2 minutes, all green on the live lab.
  • SuzieQ drift harness: continuous state polling, NetBox-vs-runtime diff with strict assertion mode, time-series queries, schema-drift smoke test. 362 default tests + 12 live tests.
  • GitHub Actions CI/CD. PR-time fabric-ci.yml on GitHub-hosted runners (lint, unit-test matrix across phases 3/4/5, render pipeline, Batfish - zero lab exposure). Manual fabric-deploy.yml on a self-hosted runner (lab-deploy environment with required reviewer): render-and-guard -> deploy with inner liveness gate -> smoke -> drift, with marker-based rollback if smoke or drift fails. End-to-end live-verified 2026-05-02..03: happy path; Variant 1 (smoke-fail -> marker walk reverts past smoke's intermediate commits); Variant 3 (liveness-fail -> Junos auto-rollback at exactly 2 min 1 s); Batfish PR-comment differential (post + find-or-update on PR re-run).

Why this project is different

This isn't an EVPN tutorial repo. It's a working model of how to operate a network with the same engineering hygiene a software team would apply to any production system:

  • Single source of truth. No config drift between docs, scripts, and devices: NetBox owns intent, everything else is derived from it.
  • Multiple independent validation layers before a device sees a candidate config: golden-file regression, on-disk deploy guard, Batfish semantic checks, then NAPALM compare.
  • Self-correcting deploys, two ways. A broken management plane (placeholder hash, mgmt VRF misconfig) trips the inner commit confirmed 120 gate and Junos auto-rolls back. A passing inner gate that later fails smoke or drift triggers deploy.py --rollback-marker, which walks each device's commit history by the deploy's unique log line and reverts to pre-deploy state. The credential-lockout postmortem in Phase 3 is the reason this was built that way.
  • Continuous drift detection post-deploy. SuzieQ keeps polling and a strict-assertions cron compares observed state against NetBox intent every 5 minutes.
  • CI gates real device-touching changes, not just code style. Public repo, Actions runners sandboxed, secrets scoped to environments, all third-party Actions pinned to commit SHAs.

5-minute demo

If you have access to the lab server, the full pipeline runs in under 5 minutes once containerlab is up:

# 1. Populate NetBox from the YAML data model
python phase1-netbox/populate.py

# 2. Bring up the fabric (4x vJunos + 4x Linux hosts in containerlab)
sudo containerlab deploy -t phase2-fabric/dc1.clab.yml

# 3. Render Junos configs from NetBox, diff against golden files
cd phase3-nornir
python deploy.py --check                  # offline diff per stanza

# 4. Validate the rendered configs offline (Batfish on netdevops-srv)
python ../phase4-batfish/validate.py --snapshot build/

# 5. Deploy. Two-layer rollback: --liveness-gate runs `commit confirmed 120`,
#    waits 30s, runs liveness on every host, then napalm_confirm_commit.
#    --commit-message stamps a unique marker for the outer rollback.
python deploy.py --commit \
    --commit-message "manual-$(date +%s)" \
    --liveness-gate

# 6. Run the smoke gate (76 checks, ~2 min)
bash ../phase2-fabric/smoke-tests.sh

# 7. If smoke or drift later fails, revert via the marker:
#    python deploy.py --rollback-marker "manual-<timestamp>"

# 8. Compare runtime state vs NetBox intent
docker compose -f /opt/suzieq/docker-compose.yml run --rm drift --mode all

CI runs the same flow non-interactively via fabric-deploy.yml (workflow_dispatch on the self-hosted lab-deploy runner) where the marker is cicd-${{ github.run_id }}-${{ github.run_attempt }}.

If you don't have the lab, the offline pieces still run: cd phase3-nornir && pytest exercises the full render pipeline with vcrpy cassettes (zero NetBox / device dependencies, ~10 seconds).

Pipeline at a glance

Step Tool Input Output
Source of truth NetBox + populate.py netbox-data.yml Devices, VLANs, VNIs, VRFs, cables in NetBox
Render Nornir + Jinja2 NetBox API (or vcrpy cassettes in CI) phase3-nornir/build/<host>.conf
Regression gate deploy.py --check Rendered configs Byte-diff vs phase3-nornir/expected/*.conf
Deploy guard assert_safe_to_deploy Rendered configs on disk Reject placeholders, validate hash shape
Validate Batfish Rendered configs + main baseline 7 offline checks + differential snapshot
Deploy (inner gate) NAPALM Candidate config commit confirmed 120 + 30s settle + liveness + napalm_confirm_commit; auto-rollback if liveness fails
Smoke smoke-tests.sh Live fabric 76-check pass/fail matrix
Rollback (outer gate) deploy.py --rollback-marker Device commit history Walk show system commit per device, revert to pre-marker state if smoke or drift fails
Observe SuzieQ + drift harness Runtime state Continuous diff vs NetBox intent

Architecture

flowchart TB
    subgraph DC1["DC1 (Juniper vJunos)"]
        sp1["dc1-spine1"]
        sp2["dc1-spine2"]

        lf1["dc1-leaf1"]
        lf2["dc1-leaf2"]

        h1["dc1-host1<br/>single-homed to leaf1"]
        h2["dc1-host2<br/>single-homed to leaf2"]
        h3["dc1-host3<br/>dual-homed<br/>ESI-LAG (ae0)"]
        h4["dc1-host4<br/>dual-homed<br/>ESI-LAG (ae1)"]

        sp1 --- lf1
        sp1 --- lf2
        sp2 --- lf1
        sp2 --- lf2

        lf1 --- h1
        lf2 --- h2

        lf1 --- h3
        lf2 --- h3

        lf1 --- h4
        lf2 --- h4
    end

    dc2["DC2 (Arista cEOS - Phase 10)"]
Loading

Topology summary:

  • Full-mesh spine-leaf fabric in DC1, each spine connects to each leaf.
  • dc1-host1 is single-homed to dc1-leaf1; dc1-host2 to dc1-leaf2.
  • dc1-host3 and dc1-host4 are dual-homed via ESI-LAG (ae0 and ae1) to both leaves.

Fabric design:

  • Juniper ERB (Edge-Routed Bridging) on vJunos-switch (EX9214)
  • eBGP underlay, unique ASN per device
  • iBGP EVPN overlay, spines as route reflectors (AS 65000)
  • VXLAN encap, VNI-to-VLAN mapping
  • ESI-LAG (EVPN multihoming) for active-active server connectivity
  • Anycast gateway on IRB for distributed L3

Evidence

Smoke suite, post-deploy (76/76 PASS, ~2 minutes)

=== 1. Control Plane ===
  PASS: dc1-spine1 BGP: 0 down peers
  PASS: leaf1 EVPN routes: 42 destinations
  PASS: leaf1 VTEP tunnel to leaf2 (10.1.0.4)
  PASS: leaf1 BFD sessions up: 4
  PASS: leaf1 ESI all-active entries: 6
  PASS: leaf1 core-isolation configured

=== 4. Failover: ESI-LAG ===
  PASS: ESI-LAG: LACP detected leaf1 failure in 5s (active aggregator: 1 port)
  PASS: ESI-LAG failover: host3 -> host4 (leaf1 crashed)
  PASS: Post-failure withdrawal: leaf2 dropped remote VTEP 10.1.0.3 in 0s
  PASS: ESI-LAG restore: leaf1 recovered

=== 5. Failover: Core Isolation ===
  PASS: Core isolation: ae0 AND ae1 both brought down in 0s
  PASS: Core isolation: host3 -> host4 (leaf1 isolated, via leaf2)

=== 8. EVPN Deep Validation ===
  PASS: leaf1 ECMP: 10.1.0.4/32 installed via 2 next-hops (both spines)
  PASS: leaf1 EVPN Type-2 (VNI 10010): 12 MAC/IP routes
  PASS: leaf1 EVPN Type-5 (IP-prefix): 4 routes
  PASS: leaf1 MTU: jumbo (size 8972 DF) -> 10.1.0.4
  PASS: DF election: 2 ESIs, both leaves agree on DF

============================================
  ALL TESTS PASSED
============================================

CI test counts (latest green run)

Phase Tests Coverage Runtime
Phase 1 (NetBox populate) 18 -- <1 s
Phase 3 (Nornir IaC) 177 87% ~22 s
Phase 4 (Batfish) 60 unit + 9 integration -- ~2 s
Phase 5 (SuzieQ) 370 default + 12 live 91.9% ~4 s
Total (default) 625 -- ~30 s

Render pipeline (offline)

Phase 3 deploy.py --check rendered against vcrpy cassettes, byte-diffed against expected/:

dc1-spine1 PASS
  OK    system
  OK    routing-options
  OK    chassis
  OK    interfaces
  OK    forwarding-options
  OK    policy-options
  OK    routing-instances
  OK    protocols

Same shape on all 4 devices. Any structural drift in a template surfaces here as a per-stanza DIFF before NAPALM is asked to do anything.

Tech Stack

Tool Purpose
NetBox Source of truth - devices, IPs, VLANs, ASNs, cabling
Containerlab Virtual network lab (vJunos-switch, Linux hosts)
pynetbox Idempotent NetBox population via Python
Nornir Configuration rendering and deployment
NAPALM Vendor-abstract device API; commit confirmed for the inner liveness gate, plain commit + Junos commit comment for the marker-based outer rollback
Batfish Pre-deployment config validation
SuzieQ Continuous state observation + drift detection
Juniper Junos Network OS (EVPN-VXLAN, ERB, ESI-LAG)
Arista EOS Multi-vendor DC2 extension (planned)

Project Phases

Phase Description Status
1 NetBox as Source of Truth Done
2 EVPN+VXLAN+ESI-LAG Fabric Done
3 Nornir IaC Framework Done
4 Batfish Pre-Deployment Validation Done
5 SuzieQ Continuous State + Drift Detection Done
6 GitHub Actions CI/CD Pipeline Done (PR-time fabric-ci.yml + deploy fabric-deploy.yml with two-layer rollback, verified live 2026-05-02)
7 Dissolved (see PROJECT_PLAN.md) -
8 CIS/PCI-DSS Hardening Planned
9 gNMI Streaming Telemetry Planned
10 Multi-DC DCI (Arista cEOS) Planned
11 Controlled Lifecycle Operations Planned
12 AI Copilot for Runtime Operations Planned

See PROJECT_PLAN.md for detailed scope of each phase.

Lessons learned

A few real incidents that shaped the design. They are the reason certain layers exist:

  • Credential lockout from a placeholder hash (Phase 3). A render bug produced placeholder password hashes; deploy.py committed them to all 4 devices and SSH locked everyone out. The fix is the two-layer safety model: a regression gate that compares against checked-in golden files, plus an independent on-disk assert_safe_to_deploy() that scans rendered bytes for sentinels and validates SHA-512 crypt shape before NAPALM is ever called. Documented in phase3-nornir/README.md "Safety - the two-layer guard".

  • Falsely blamed Junos for a SuzieQ pipeline artifact (Phase 5). Drift detection started reporting "every BGP peer appears twice" - the working theory was Junos emitting duplicate state. Three hours of vendor-blame later, the actual root cause was a SuzieQ multi-command merge pipeline that produces partial-view rows during state transitions. The lesson: default to "your code is wrong, not the vendor's", and verify the raw output before reaching for a workaround. Now codified as a project rule and an explicit _cleanup_bgp_phantom_rows() helper.

  • vJunos MTU cap (Phase 2). Real EX9214 supports 9216 MTU; the vJunos-switch image silently caps at 9192. Smoke test was sending 8972-byte (DF) pings between leaves - works at 9192 but would have failed on a real EX. The MTU constant lives in vars/junos_defaults.yml so the difference is one line, but the lesson is that emulation has invisible limits and the smoke suite needs to actively probe them.

  • LAG system-id regex bug invisible at small scale (Phase 3). The original ESI-LAG system-id formula was f"00:00:00:00:0{ae_index + 3}:00" - works fine for ae0..ae6 but produces 00:00:00:00:010:00 (an invalid 3-character octet) for ae7+. Phase 2 only had ae0 and ae1 so this hid for months. Caught by extending parametrized tests across the realistic range, not by the smoke suite or by manual review. Now phase3-nornir/tests/test_lag_system_id.py parametrizes over ae0/1/6/7/12/13/252 and pins a 6-octet MAC regex.

  • instance-import does not work on vrf instance-type (Phase 7 PoC). A Phase 7 plan iteration specified selective tenant-VRF leaking via instance-import policies. A 1-hour live PoC caught the assumption: Junos rejects instance-import on instance-type vrf with 'instance-import' not allowed on VPN instance. The primitive applies to virtual-router and similar non-VPN instance-types only. EVPN multi-tenancy requires vrf for L3VNI signaling, so the primitive is structurally unavailable for this use case. The working alternative for selective cross-VRF leak with vrf instance-type is routing-options rib-groups with an import-policy, bound via routing-instances <vrf> routing-options static rib-group <name>. Lesson: VPN instance-types and virtual-router instance-types expose different sets of routing-options primitives. If a primitive appears in the docs, check which instance-type section it sits under before assuming it works for VRFs.

  • vJunos does not install novel Type-5 prefixes into the receiver VRF inet table (Phase 7 PoC). While disambiguating the route-leak design, the PoC discovered that vJunos 23.2R1.14 receives Type-5 EVPN routes correctly into bgp.evpn.0 and <vrf>.evpn.0 with Import Accepted, but never installs them into <vrf>.inet.0. Tested across five origin configurations (rib-group static-discard, direct static-discard, direct static with real next-hop, attempted lo0 unit, fresh /29 prefix) - none propagate to the remote leaf. The lab's existing ERB design happens to mask this because every tenant subnet has a local anycast IRB Direct route on every leaf, so the Type-5 install path is never actually exercised in normal operation. Likely cause: incomplete PFE programming (the forwarding-options vxlan-routing hierarchy is parser-rejected on vJunos). Real EX9214 hardware does this correctly. Lesson: emulator gaps can hide behind anycast designs. The smoke suite passes because anycast IRBs provide local Direct routes, not because the Type-5 receive-side install is working - which on this image it isn't.

  • add-path is not for EVPN signaling family (Phase 7 PoC). A Phase 7 plan iteration proposed BGP add-path send-receive on the spines for the EVPN overlay - a suggestion that came up in review and seemed obvious enough to plan around. Junos rejects this combination at commit-check time on every release tested (23.2 / 23.4 / 24.2): the YANG parser accepts the syntax, but the BGP module checker returns BGP: Add-path configured on unsupported address-family. The add-path family enum is restricted to inet | inet6 | inet-vpn | inet6-vpn | iso-vpn. For EVPN overlay multipath, the documented primitive is multipath on the BGP group, not add-path. Lesson: "should obviously work" is a tell. The standard EVPN-VXLAN reference designs use multipath and never mention add-path for the EVPN overlay - that absence was the diagnostic signal. The PoC caught it before scope was locked, but a doc check on the Junos add-path family enum would have caught it earlier.

Repository Structure

evpn-lab/
+-- README.md                    # This file
+-- PROJECT_PLAN.md               # 12-phase roadmap
+-- .env.example                  # Environment variable template
+-- .github/workflows/            # GitHub Actions (fabric-ci.yml + fabric-deploy.yml)
+-- phase1-netbox/                # NetBox as Source of Truth
+-- phase2-fabric/                # EVPN+VXLAN+ESI-LAG fabric (containerlab + smoke)
+-- phase3-nornir/                # Nornir IaC: render, guard, deploy
|   +-- tests/                    # 177 unit/integration tests, vcrpy cassettes
|   +-- expected/                 # Golden file regression baselines
|   +-- templates/junos/          # Jinja2 templates per stanza
+-- phase4-batfish/               # Pre-deployment offline validation
+-- phase5-suzieq/                # Continuous state observation + drift detection
+-- phase6-cicd/                  # CI/CD docs, helper scripts (workflows live in .github/)

IP Addressing Plan

Block Purpose
10.0.0.0/24 Inter-DC P2P links
10.1.0.0/16 DC1 infrastructure (loopbacks, P2P)
10.2.0.0/16 DC2 infrastructure (Phase 10)
10.10.0.0/16 Tenant subnets stretched across DCs
10.11.0.0/16 DC1 local tenant subnets
10.12.0.0/16 DC2 local tenant subnets (Phase 10)

Each DC summarizes to a single /16. See Phase 1 docs for the full object inventory.