Value IP PDU

Home Assistant integration for the VALUE 8-port IP PDU (OEM: LIU-0816-WN, 16 A, IEC-320 C13 x8) — the rack power strip reachable at http://<ip>/ with the classic Microchip TCP/IP web UI.

Provides per-outlet switch control (ON/OFF), per-outlet power-cycle buttons (ON/OFF cycle), and total power metering fed from the device's current sensor: current, computed power, accumulated energy, temperature, and humidity.

No official Home Assistant integration exists for this device. This integration talks directly to the device's built-in HTTP interface (HTTP Basic auth), so no cloud or external service is involved (local_polling).

Features

Entity Type Notes
Outlet 1–8 Switch Turn each of the 8 C13 outlets on/off (read-only if locked)
Outlet 1–8 cycle Button Power-cycle (ON/OFF) a single outlet (hidden for read-only outlets)
Total current Sensor A (measured by the PDU)
Total power Sensor W = voltage × current (computed)
Total energy Sensor kWh (accumulated, survives HA restarts)
Voltage used Sensor V (diagnostic — shows which voltage source was used)
Temperature Sensor °C (built-in sensor)
Humidity Sensor % (built-in sensor)

All entities are grouped under a single Value IP PDU device.

Energy Dashboard

The Total power sensor (sensor.*_total_power, device_class: power) is all you need to add the PDU to the HA Energy Dashboard:

Settings → EnergyElectricity gridAdd consumptionUse an entity → select Total power (or Total energy).

Power calculation & voltage source

Why an external voltage source? The VALUE IP PDU measures voltage and shows it on its front LED display — but its web interface never exposes it (the firmware only serves current, temperature, humidity and outlet states via HTTP; voltage appears in the UI solely as a threshold-setting field). Since we can't read the real voltage over the network, power is computed as W = voltage × current, where voltage is resolved in this order:

  1. Voltage source sensor — an HA entity you select in the options (e.g. a rack PDU meter or smart plug that already measures the feed voltage). Read live on every poll.
  2. Nominal voltage — configurable constant, default 230 V, used when no source sensor is configured.

For the most accurate energy dashboard numbers, point the voltage source at a real voltage sensor measuring the same feed the PDU is on. If you only care about relative consumption, the nominal constant is fine.

Installation

HACS (recommended)

  1. HACS → ⋮ → Custom repositories
  2. Add https://github.com/jaggr2/home-assistant-value-pdu as an Integration
  3. Search for Value IP PDUDownload → restart Home Assistant
  4. Settings → Devices & services → Add integrationValue IP PDU

Manual

git clone https://github.com/jaggr2/home-assistant-value-pdu.git
cp -r home-assistant-value-pdu/custom_components/value_pdu <config>/custom_components/

Restart Home Assistant, then add the integration from Settings → Devices & services.

Configuration

During setup you provide:

  • Host — IP / hostname of the PDU (e.g. 192.168.1.4)
  • Username / Password — HTTP Basic auth credentials (device default admin / admin)
  • Poll interval — default 30 s (min 10 s)
  • Nominal voltage — default 230 V
  • Voltage source sensor — optional; any HA sensor with device_class: voltage

Username, password, poll interval, nominal voltage and voltage source can all be changed later via the entry's Configure (options) dialog — the integration reloads automatically, so credential changes don't require removing and re-adding the entry.

Outlet names

The options dialog also lets you give each outlet a name (e.g. which device is plugged into it). These names become the friendly names of the outlet switches and cycle buttons (Value PDU <name>), while entity IDs stay fixed to the port number — so renaming never breaks your automations. They are stored in Home Assistant, not on the PDU.

Read-only (lockout) outlets

For security, you can mark any outlet as read-only in the options dialog. A read-only outlet:

  • Keeps its switch visible with live on/off state, but any ON/OFF command is rejected with a clear error ("Outlet N is read-only — it cannot be switched").
  • Gets no power-cycle button (and value_pdu.cycle_outlet refuses it).
  • The lockout is enforced in the coordinator — the single control path — so switches, buttons and services can never bypass it.

Automations can still read the switch state of a locked outlet; they just cannot change it.

ON/OFF delays

The PDU applies a configurable ON delay and OFF delay per outlet (set in the PDU's own web UI under PDU → Socket). The integration reads these delays from the device and accounts for them when switching:

  • After you toggle an outlet, the switch keeps showing the target state instead of reverting when the first poll still reads the old (not-yet-switched) state.
  • A refresh is scheduled for when the delay elapses, so the UI confirms the physical change at the right moment.
  • Each switch exposes its current on_delay / off_delay (seconds) as state attributes.
  • While an outlet is within its delay window, further commands on it are rejected (switch, cycle button, and value_pdu.cycle_outlet) with a clear "still switching — wait for the ON/OFF delay" error.

value_pdu.cycle_outlet service

Power-cycles an outlet for use in automations (buttons cover this in the UI):

service: value_pdu.cycle_outlet
data:
  outlet: 3   # 0-based index 0..7

Device API reference

The device exposes a small HTTP surface (all responses gzip-encoded):

  • GET /status.xml — telemetry:
    • cur0 / curBan → total current (A)
    • tempBan → temperature (°C), humBan → humidity (%)
    • outletStat0outletStat7on / off
    • stat0 / statBannormal | curwarning | curoverload | volwarning | voloverload | tempwarning | humwarning
  • GET /control_outlet.htm?outlet0=1&outlet3=1&op=X — control selected outlets with op: 0 = ON, 1 = OFF, 2 = ON/OFF cycle

Troubleshooting

  • Cannot connect: verify the host is reachable (curl -u admin:admin http://<ip>/) and that the username/password are correct.
  • Power shows 0 W: the device reports 0.0 A (no load). Check the LED display on the unit.
  • Voltage source not updating: the source entity must report a positive numeric state (device_class: voltage). Otherwise the nominal constant is used — see the Voltage used diagnostic sensor.

Development

pip install -r requirements-dev.txt
pytest

License

Apache-2.0. This project is not affiliated with VALUE or Home Assistant.