Notifications
You must be signed in to change notification settings - Fork 2
impitool
Hippie Hacker edited this page May 4, 2015
·
1 revision
modprobe ipmi_devintf modprobe ipmi_si
Set in Progress : Set Complete
Auth Type Support : NONE MD2 MD5 PASSWORD
Auth Type Enable : Callback : MD2 MD5 PASSWORD
: User : MD2 MD5 PASSWORD
: Operator : MD2 MD5 PASSWORD
: Admin : MD2 MD5 PASSWORD
: OEM : MD2 MD5 PASSWORD
IP Address Source : DHCP Address
IP Address : 192.168.3.31
Subnet Mask : 255.255.255.0
MAC Address : 00:25:90:7e:a7:0d
SNMP Community String : public
IP Header : TTL=0x00 Flags=0x00 Precedence=0x00 TOS=0x00
BMC ARP Control : ARP Responses Enabled, Gratuitous ARP Disabled
Default Gateway IP : 192.168.3.1
Default Gateway MAC : f8:7b:8c:17:28:ad
Backup Gateway IP : 0.0.0.0
Backup Gateway MAC : 00:00:00:00:00:00
802.1q VLAN ID : Disabled
802.1q VLAN Priority : 0
RMCP+ Cipher Suites : 1,2,3,6,7,8,11,12
Cipher Suite Priv Max : aaaaXXaaaXXaaXX
: X=Cipher Suite Unused
: c=CALLBACK
: u=USER
: o=OPERATOR
: a=ADMIN
: O=OEM
usage: lan set <channel> <command> <parameter>
LAN set command/parameter options:
ipaddr <x.x.x.x> Set channel IP address
netmask <x.x.x.x> Set channel IP netmask
macaddr <x:x:x:x:x:x> Set channel MAC address
defgw ipaddr <x.x.x.x> Set default gateway IP address
defgw macaddr <x:x:x:x:x:x> Set default gateway MAC address
bakgw ipaddr <x.x.x.x> Set backup gateway IP address
bakgw macaddr <x:x:x:x:x:x> Set backup gateway MAC address
password <password> Set session password for this channel
snmp <community string> Set SNMP public community string
user Enable default user for this channel
access <on|off> Enable or disable access to this channel
alert <on|off> Enable or disable PEF alerting for this channel
arp respond <on|off> Enable or disable BMC ARP responding
arp generate <on|off> Enable or disable BMC gratuitous ARP generation
arp interval <seconds> Set gratuitous ARP generation interval
vlan id <off|<id>> Disable or enable VLAN and set ID (1-4094)
vlan priority <priority> Set vlan priority (0-7)
auth <level> <type,..> Set channel authentication types
level = CALLBACK, USER, OPERATOR, ADMIN
type = NONE, MD2, MD5, PASSWORD, OEM
ipsrc <source> Set IP Address source
none = unspecified source
static = address manually configured to be static
dhcp = address obtained by BMC running DHCP
bios = address loaded by BIOS or system software
cipher_privs XXXXXXXXXXXXXXX Set RMCP+ cipher suite privilege levels
X = Cipher Suite Unused
c = CALLBACK
u = USER
o = OPERATOR
a = ADMIN
O = OEM
System Power : on Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : previous Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false
ipmitool> chassis power status Chassis Power is on
Chassis identify interval: default (15 seconds) ipmitool>
chassis policy <state> list : return supported policies always-on : turn on when power is restored previous : return to previous state when power is restored always-off : stay off after power is restored ipmitool> chassis policy list Supported chassis power policy: previous
System restart cause: unknown
POH Counter : 0 days, 0 hours
bootdev <device> [clear-cmos=yes|no] bootdev <device> [options=help,...] none : Do not change boot device order pxe : Force PXE boot disk : Force boot from default Hard-drive safe : Force boot from default Hard-drive, request Safe Mode diag : Force boot from Diagnostic Partition cdrom : Force boot from CD/DVD bios : Force boot into BIOS Setup floppy: Force boot from Floppy/primary removable media ipmitool> chassis bootdev disk options=help Legal options settings are: help: print this message valid: Boot flags valid persistent: Changes are persistent for all future boots efiboot: Extensible Firmware Interface Boot (EFI) clear-cmos: CMOS clear lockkbd: Lock Keyboard screenblank: Screen Blank lockoutreset: Lock out Resetbuttons lockout_power: Lock out (power off/sleep request) via Power Button verbose=default: Request quiet BIOS display verbose=no: Request quiet BIOS display verbose=yes: Request verbose BIOS display force_pet: Force progress event traps upw_bypass: User password bypass lockout_sleep: Log Out Sleep Button cons_redirect=default: Console redirection occurs per BIOS configuration setting cons_redirect=skip: Suppress (skip) console redirection if enabled cons_redirect=enable: Suppress (skip) console redirection if enabled
bootparam get <param #> bootparam set bootflag <device> [options=...] Legal devices are: none : No override force_pxe : Force PXE boot force_disk : Force boot from default Hard-drive force_safe : Force boot from default Hard-drive, request Safe Mode force_diag : Force boot from Diagnostic Partition force_cdrom : Force boot from CD/DVD force_bios : Force boot into BIOS Setup Legal options are: help : print this message PEF : Clear valid bit on reset/power cycle cause by PEF timeout : Automatically clear boot flag valid bit on timeout watchdog: Clear valid bit on reset/power cycle cause by watchdog reset : Clear valid bit on push button reset/soft reset power : Clear valid bit on power up via power push button or wake event Any Option may be prepended with no- to invert sense of operation
usage: event <num> Send generic test events 1 : Temperature - Upper Critical - Going High 2 : Voltage Threshold - Lower Critical - Going Low 3 : Memory - Correctable ECC usage: event file <filename> Read and generate events from file Use the 'sel save' command to generate from SEL usage: event <sensorid> <state> [event_dir] sensorid : Sensor ID string to use for event data state : Sensor state, use 'list' to see possible states for sensor event_dir : assert, deassert [default=assert]
Not enough parameters given.
MC Commands:
reset <warm|cold>
guid
info
watchdog <get|reset|off>
selftest
getenables
setenables <option=on|off> ...
recv_msg_intr Receive Message Queue Interrupt
event_msg_intr Event Message Buffer Full Interrupt
event_msg Event Message Buffer
system_event_log System Event Logging
oem0 OEM 0
oem1 OEM 1
oem2 OEM 2
getsysinfo <argument>
setsysinfo <argument> <string>
primary_os_name Primary operating system name
os_name Operating system name
system_name System Name of server(vendor dependent)
delloem_os_version Running version of operating system
delloem_url URL of BMC webserver
System GUID : 31303037-534d-2500-907e-a70d00000000 Timestamp : 02/25/1996 01:47:35
Device ID : 32
Device Revision : 1
Firmware Revision : 3.19
IPMI Version : 2.0
Manufacturer ID : 10876
Manufacturer Name : Supermicro
Product ID : 1640 (0x0668)
Product Name : Unknown (0x668)
Device Available : yes
Provides Device SDRs : no
Additional Device Support :
Sensor Device
SDR Repository Device
SEL Device
FRU Inventory Device
IPMB Event Receiver
IPMB Event Generator
Chassis Device
Receive Message Queue Interrupt : enabled Event Message Buffer Full Interrupt : disabled Event Message Buffer : enabled System Event Logging : enabled OEM 0 : disabled OEM 1 : disabled OEM 2 : disabled
CPU Temp | 36 degrees C | ok System Temp | 27 degrees C | ok Peripheral Temp | 37 degrees C | ok PCH Temp | 45 degrees C | ok FAN 1 | 3450 RPM | ok Vcore | 0.86 Volts | ok 3.3VCC | 3.31 Volts | ok 12V | 11.98 Volts | ok VDIMM | 1.50 Volts | ok 5VCC | 5.02 Volts | ok VBAT | 3.22 Volts | ok VSB | 3.31 Volts | ok AVCC | 3.31 Volts | ok PS Status | 0x01 | ok
CPU Temp | 37.000 | degrees C | ok | 0.000 | 0.000 | 0.000 | 86.000 | 89.000 | 91.000 System Temp | 27.000 | degrees C | ok | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 Peripheral Temp | 37.000 | degrees C | ok | -9.000 | -7.000 | -5.000 | 80.000 | 85.000 | 90.000 PCH Temp | 45.000 | degrees C | ok | -11.000 | -8.000 | -5.000 | 90.000 | 95.000 | 100.000 FAN 1 | 3450.000 | RPM | ok | 300.000 | 450.000 | 600.000 | 18975.000 | 19050.000 | 19125.000 Vcore | 0.816 | Volts | ok | 0.480 | 0.512 | 0.544 | 1.488 | 1.520 | 1.552 3.3VCC | 3.312 | Volts | ok | 2.816 | 2.880 | 2.944 | 3.584 | 3.648 | 3.712 12V | 11.978 | Volts | ok | 10.494 | 10.600 | 10.706 | 13.091 | 13.197 | 13.303 VDIMM | 1.496 | Volts | ok | 1.152 | 1.216 | 1.280 | 1.760 | 1.776 | 1.792 5VCC | 5.024 | Volts | ok | 4.096 | 4.320 | 4.576 | 5.344 | 5.600 | 5.632 VBAT | 3.216 | Volts | ok | 2.816 | 2.880 | 2.944 | 3.584 | 3.648 | 3.712 VSB | 3.312 | Volts | ok | 2.816 | 2.880 | 2.944 | 3.584 | 3.648 | 3.712 AVCC | 3.312 | Volts | ok | 2.816 | 2.880 | 2.944 | 3.584 | 3.648 | 3.712 PS Status | 0x1 | discrete | 0x0100| na | na | na | na | na | na
FRU Device Description : Builtin FRU Device (ID 0) Board Mfg Date : Sun Dec 31 16:00:00 1995 Board Mfg : Supermicro Board Serial : Product Serial :
SEL Information Version : 1.5 (v1.5, v2 compliant) Entries : 512 Free Space : 0 bytes Percent Used : 100% Last Add Time : 10/05/2014 21:10:27 Last Del Time : Not Available Overflow : true Supported Cmds : 'Reserve' 'Get Alloc Info' # of Alloc Units : 512 Alloc Unit Size : 20 # Free Units : 0 Largest Free Blk : 0 Max Record Size : 20
0x51 | 16 | 16 | 37303031-4d53-0025-907e-a70d00000000 | Alert,Power-off,Reset,Power-cycle,OEM-defined
SOL Commands: info [<channel number>]
set <parameter> <value> [channel]
payload <enable|disable|status> [channel] [userid]
activate [<usesolkeepalive|nokeepalive>] [instance=<number>]
deactivate [instance=<number>]
looptest [<loop times> [<loop interval(in ms)> [<instance>]]]
Set in progress : set-complete Enabled : true Force Encryption : false Force Authentication : false Privilege Level : USER Character Accumulate Level (ms) : 0 Character Send Threshold : 0 Retry Count : 0 Retry Interval (ms) : 0 Volatile Bit Rate (kbps) : 115.2 Non-Volatile Bit Rate (kbps) : 115.2 Payload Channel : 1 (0x01) Payload Port : 623
User Commands: summary [<channel number>] list [<channel number>] set name <user id> <username> set password <user id> [<password>] disable <user id> enable <user id> priv <user id> <privilege level> [<channel number>] test <user id> <16|20> [<password]> ipmitool> user summary Maximum IDs : 10 Enabled User Count : 2 Fixed Name Count : 2 ipmitool> user list ID Name Callin Link Auth IPMI Msg Channel Priv Limit 2 ADMIN true false false Unknown (0x00)
channel
Channel Commands: authcap <channel number> <max privilege>
getaccess <channel number> [user id]
setaccess <channel number> <user id> [callin=on|off] [ipmi=on|off] [link=on|off] [privilege=level]
info [channel number]
getciphers <ipmi | sol> [channel]
Possible privilege levels are:
1 Callback level
2 User level
3 Operator level
4 Administrator level
5 OEM Proprietary level
15 No access
ipmitool> channel info
Channel 0xf info:
Channel Medium Type : System Interface
Channel Protocol Type : KCS
Session Support : session-less
Active Session Count : 0
Protocol Vendor ID : 7154
ipmitool> channel getciphers ipmi
Get Channel Cipher Suites failed: Invalid data field in request
ipmitool> channel getciphers ipmi 1
ID IANA Auth Alg Integrity Alg Confidentiality Alg
0 N/A none none none
1 N/A hmac_sha1 none none
2 N/A hmac_sha1 hmac_sha1_96 none
3 N/A hmac_sha1 hmac_sha1_96 aes_cbc_128
4 N/A hmac_sha1 hmac_sha1_96 xrc4_128
5 N/A hmac_sha1 hmac_sha1_96 xrc4_40
6 N/A hmac_md5 none none
7 N/A hmac_md5 hmac_md5_128 none
8 N/A hmac_md5 hmac_md5_128 aes_cbc_128
9 N/A hmac_md5 hmac_md5_128 xrc4_128
10 N/A hmac_md5 hmac_md5_128 xrc4_40
11 N/A hmac_md5 md5_128 none
12 N/A hmac_md5 md5_128 aes_cbc_128
13 N/A hmac_md5 md5_128 xrc4_128
14 N/A hmac_md5 md5_128 xrc4_40
??
Supported DCMI capabilities:
Mandatory platform capabilties
Identification support available
SEL logging available
Chassis power available
Temperature monitor available
Optional platform capabilties
Power management available
Managebility access capabilties
In-band KCS channel available
Out-of-band primary LAN channel available
SOL enabled
VLAN capable
Mandatory platform attributes:
SEL Attributes:
SEL automatic rollover is not present
512 SEL entries
Identification Attributes:
GUID
Asset tag
Temperature Monitoring Attributes:
inlet
cpu
baseboard
Optional Platform Attributes:
Power Management:
Slave address of device: 20h (8bits)(Satellite/External controller)
Channel number is 0h (Primary BMC)
Device revision is 1
Manageability Access Attributes:
Primary LAN channel number: 1 is available
Secondary LAN channel is not available for OOB
No serial channel is available
Instantaneous power reading: 66 Watts Minimum during sampling period: 35 Watts Maximum during sampling period: 134 Watts Average power reading over sample period: 61 Watts IPMI timestamp: Sun Oct 5 20:53:31 2014 Sampling period: 519348000 Milliseconds Power reading state is: activated
Get Management Controller Identifier String: MYBLADE