Update vtx_tramp.c - #11772
Conversation
vtx 2500
|
ⓘ Qodo reviews are paused because the subscription is no longer active. Ask your workspace admin to reactivate the subscription to resume reviews. Manage billing |
Branch Targeting SuggestionYou've targeted the
If This is an automated suggestion to help route contributions to the appropriate branch. |
PR Summary by QodoAdd 2.5W power table selection for Tramp 5.8GHz VTX
AI Description
Diagram
High-Level Assessment
Files changed (1)
|
Code Review by Qodo
1. 800mW power capped
|
| if (maxPower >= 2500) { | ||
| vtxState.metadata.powerTablePtr = trampPowerTable_5G8_2500; | ||
| vtxState.metadata.powerTableCount = 4; | ||
|
|
There was a problem hiding this comment.
1. 800mw power capped 🐞 Bug ≡ Correctness
vtxProtoUpdatePowerMetadata() now only selects the new 2500mW table when maxPower>=2500; a TRAMP VTX reporting maxPower=800 will fall through to the 600mW table and can never request 800mW. This causes incorrect capability metadata and prevents users from using the device’s supported max power.
Agent Prompt
## Issue description
The TRAMP 5.8GHz power metadata selection no longer handles devices whose reported `maxPower` is >=800mW but <2500mW, so those devices use the 600mW table and cannot select 800mW.
## Issue Context
`vtxProtoProcessResponse()` reads `capabilities.powerMax` from the VTX and calls `vtxProtoUpdatePowerMetadata(powerMax)`. Power selection (`impl_SetPowerByIndex`) uses `vtxState.metadata.powerTablePtr` values; if the selected table does not include 800, the firmware cannot ever request 800mW (even though it caps requested power to `powerMax`).
## Fix Focus Areas
- src/main/io/vtx_tramp.c[563-574]
- src/main/io/vtx_tramp.c[581-645]
- src/main/io/vtx_tramp.c[428-443]
## Proposed fix
1. Reintroduce the 5.8GHz 800mW power table + names (the prior 25/100/200/500/800 mapping).
2. Add an `else if (maxPower >= 800)` branch between the 2500 and 600 branches to select that table and set matching `powerTableCount`/`capability.powerCount`.
3. Keep the 2500mW handling as the top branch for `maxPower >= 2500`.
ⓘ Copy this prompt and use it to remediate the issue with your preferred AI generation tools
|
Just an FYI for contributors: The tentative schedule for INAV 10 is to have a full release in mid December. That means RC2 needs to be in early to mid November, which places INAV 10.0RC1 at September 1. Please plan to have any new features for INAV 10.0 ready for RC1 no later than September 1. After that, 10.1 will follow about six to seven months later. |