Bring an MBus heat / hot-water meter (e.g. Icelandic hitaveita district heating) into Home Assistant when it's attached to a HomeWizard Wi-Fi P1 meter — including volume, live flow, supply/return temperature, heat energy, a monthly usage meter, and a simple cost estimate.
Why this is needed: the HomeWizard P1 exposes your electricity meter through its local
GET /api/v1/data, and HA's official HomeWizard integration uses that. But an attached MBus heat/water meter is not parsed into theexternalarray of/api/v1/data(it comes back"external": []). The data is present in the raw P1 telegram (GET /api/v1/telegram) on MBus channel0-1:24.2.x, so this project scrapes the telegram with a small REST sensor.
No add-ons or custom components required — just YAML.
You can use this if all of these are true:
- You have a HomeWizard Wi-Fi P1 meter with the local API enabled (HomeWizard app → device → Local API).
- A heat / hot-water (MBus) meter is connected to your smart meter's P1 port (common with Icelandic hitaveita, and some district-heating setups elsewhere).
- The meter's readings appear in the telegram but not in
/api/v1/data'sexternalarray.
Quick check (replace the IP with your P1's address):
# Electricity only? Heat meter missing here?
curl -s http://YOUR_P1_IP/api/v1/data | grep external # often: "external":[]
# But present in the raw telegram on an MBus channel:
curl -s http://YOUR_P1_IP/api/v1/telegram | grep -E '0-1:24\.2\.'Example telegram lines (this is what we parse):
0-1:24.2.1(1234.567*m3) # cumulative volume
0-1:24.2.2(0000.050*m3/h) # live flow
0-1:24.2.3(000070.0*degC) # supply temperature
0-1:24.2.4(000035.0*degC) # return temperature
0-1:24.2.5(0123.456*Wh) # heat energy register
Find your channel. The examples use MBus channel
0-1. Some installs put the heat meter on0-2or0-3. Run thegrepabove; if you see0-2:24.2.xinstead, change0-1to0-2everywhere inpackages/hitaveita.yaml.
In configuration.yaml:
homeassistant:
packages: !include_dir_named packagesCopy packages/hitaveita.yaml into your HA config/packages/ folder
and edit two things:
- replace
YOUR_P1_IPwith your P1 meter's IP, - confirm the MBus channel (
0-1by default — see above).
(Alternatively, paste the contents of the package straight into configuration.yaml.)
- Developer Tools → YAML → Check configuration, then Restart.
⚠️ On a low-RAM Home Assistant VM (≤1 GiB),ha core check/ restarts can thrash. 2 GiB+ recommended.
- Set
input_number.hitaveita_verd_per_m3to your tariff (ISK per m³) in the UI. - Add
sensor.hitaveita_rummalunder Settings → Dashboards → Energy → Water consumption (it'sdevice_class: water+state_class: total_increasing, and the Energy dashboard can apply a static price for cost there too). - Optional dashboard:
dashboards/orka.yaml(see its header for how to register a YAML dashboard).
Entity (default entity_id) |
What |
|---|---|
sensor.hitaveita_rummal |
Cumulative volume (m³) |
sensor.hitaveita_rennsli |
Live flow (L/min — see gotcha #2) |
sensor.hitaveita_framrasarhiti |
Supply temperature (°C) |
sensor.hitaveita_bakrasarhiti |
Return temperature (°C) |
sensor.hitaveita_orka |
Heat energy register (Wh) — no state_class (see Troubleshooting) |
sensor.hitaveita_rummal_manudur |
Volume this month (resets on the 1st) |
input_number.hitaveita_verd_per_m3 |
Tariff (ISK/m³), set in UI |
sensor.hitaveita_kostnadur_manudur |
Cost this month = monthly m³ × price |
sensor.hitaveita_kostnadur_uppsafnadur |
Lifetime cost = total m³ × price |
entity_ids are derived from the (Icelandic) names. If you rename the sensors, update the cross-references in the package (utility_meter.sourceand the two cost templates).
/api/v1/datawon't show the heat meter (external: []). Use the telegram. (If HomeWizard ever parses MBus "heat" intoexternal, the official integration would expose it natively — seedocs/HOMEWIZARD_FEATURE_REQUEST.md.)- Flow showed
0in the dashboard.device_class: volume_flow_rateis unit-convertible, so HA converted ourL/minback tom³/h(~0.05) which rounds to0. Fix: report flow in L/min with no device_class so it displays literally (idle hitaveita circulation ≈ 1 L/min; a shower ≈ 8–15 L/min). - There is no live price API for hitaveita — it's a fixed tariff (and bills often add a standing
charge / energy component). So price is a manual
input_number; treat cost as an estimate. - The "energy" register (
24.2.5) may not be a lifetime counter. It is often a small / rolling value, so this package sets nostate_classonsensor.hitaveita_orka— keeping it out of long-term statistics / the Energy dashboard, where a non-monotonic value would be misleading. Volume (m³) is the meaningful usage figure. Only addstate_class: total_increasingif you have verified your meter's24.2.5is monotonically increasing. - The telegram has two
0-1:24.2.1(...)lines (a timestamp and the volume). The regex matches only the*m3one.
- A sensor shows Unavailable (not 0). Each sensor is available only when its telegram line is
found, so Unavailable means the regex did not match — usually the wrong MBus channel, or the
line is absent from your telegram. This is by design (better than a misleading
0). - Wrong MBus channel. The package assumes
0-1. Runcurl -s http://YOUR_P1_IP/api/v1/telegram | grep -E '24\.2\.'; if your lines start with0-2:or0-3:, change0-1to that channel everywhere inpackages/hitaveita.yaml. - Local API disabled. Enable it in the HomeWizard app -> your P1 -> Local API. Verify:
curl -s http://YOUR_P1_IP/apishould return device info (product/firmware). - Telegram endpoint unreachable.
curl -s http://YOUR_P1_IP/api/v1/telegram | headfrom a host on the same network. Check the IP and that HA can reach it. - Cost / monthly sensors stay empty (slug mismatch). They reference
sensor.hitaveita_rummal, the slug HA derives from the name "Hitaveita – Rúmmál". If your install generated a differententity_id(check Developer Tools -> States), updateutility_meter.hitaveita_manudur.sourceand the two cost templates to match. - Dashboard "Entity not found" for
sensor.p1_meter_*. Those electricity entities are examples from the official HomeWizard integration and differ per install — not a bug in this package. Swap in your own entity_ids (Developer Tools -> States). Hitaveita – Orkais missing from the Energy dashboard. Intentional — it has nostate_classbecause register24.2.5may not be lifetime-increasing (see gotcha #4).- Flow is shown in L/min, not m³/h. Intentional: the telegram reports m³/h, which is tiny for
domestic use and rounds to
0in cards. We convertm³/h × 1000 ÷ 60 = L/minand expose a plain L/min sensor (nodevice_class, so HA does not convert it back).
packages/hitaveita_monitor.yaml is an optional add-on package that builds derived monitoring on
top of the base sensors — useful for spotting high return temperature, poor heat extraction
(low delta-T), and continuous / abnormal flow. It does not change the base package.
This is not a billing or certified-measurement system — just a convenience monitor. Tune the thresholds per house; the suggested values are only starting points.
Install: drop packages/hitaveita_monitor.yaml into config/packages/ (same as the base
package) and restart. It depends on the base package's entity_ids
sensor.hitaveita_framrasarhiti (supply), sensor.hitaveita_bakrasarhiti (return) and
sensor.hitaveita_rennsli (flow); if yours differ, update the references at the top of the file.
Tunable helpers (set them in the UI):
input_number.hitaveita_high_return_threshold(°C)input_number.hitaveita_min_active_flow_l_min(L/min)input_number.hitaveita_low_delta_t_threshold(°C)input_number.hitaveita_continuous_flow_l_min(L/min)
Derived entities:
sensor.hitaveita_delta_t— supply − return (nodevice_class: a temperature difference must not be unit-converted like an absolute temperature).binary_sensor.hitaveita_flow_active— flow above the minimum-active threshold.binary_sensor.hitaveita_high_return_temperature— return above threshold and flow active.binary_sensor.hitaveita_poor_heat_extraction— delta-T below threshold and flow active.binary_sensor.hitaveita_continuous_flow_candidate— flow above the continuous-flow threshold.
Alerts are optional and documented separately. The monitoring package is sensors/helpers only —
you can simply watch the warning binary_sensors on a dashboard. If you also want to be notified,
copy a ready-made automation from docs/ALERTS.md and point it at your own
notify. service (phone push, email, etc.). The examples are time-debounced (30 min / 6 h) to avoid
false alarms. Alerts are not required for the package to work.
Why "high return only while flow is active": a warm return reading with no draw is just standing water cooling slowly, not a problem — the alert is only meaningful while hot water is actually moving.
Glossary: framrás(arhiti) = supply temperature, bakrás(arhiti) = return temperature, delta-T = supply − return.
This relies on the HomeWizard local API v1, which is unauthenticated on your LAN — anything that can reach the P1 can read your energy + hot-water usage (and Wi-Fi SSID). HA needs it on, so:
- Do not expose the P1 to the internet (no router port-forward to it).
- Prefer putting IoT devices on a separate VLAN / restricted subnet.
- The newer HomeWizard v2 API (HTTPS, token) is auth'd, but does not change the MBus parsing gap.
- Best fix for everyone: ask HomeWizard to expose MBus heat in
/api/v1/data→docs/HOMEWIZARD_FEATURE_REQUEST.md. - Prefer not to copy-paste? An optional, credential-free prompt that generates a tailored
package from your own telegram is in
docs/GENERATOR_PROMPT.md. It does not require giving any tool access to your Home Assistant.
PRs welcome for other MBus device types (water, gas) and non-ISK currencies.