OneMeter — Home Assistant integration (unofficial)

Home Assistant custom integration for the OneMeter BLE energy-meter optical reader (the Polish nRF51822-based device). Talks to the stock device firmware over BLE through an ESPHome bluetooth_proxy (or any other Home-Assistant-supported Bluetooth adapter), decrypts the proprietary protocol, and exposes the device — and when a real meter is attached, its meter-register readings — as native HA sensors.

Unofficial — not affiliated with OneMeter sp. z o.o.

Backstory

When OneMeter went bankrupt and turned off their cloud, I got a little bit annoyed and decided to build my own integration. It works — but the main limitation is that you need to extract your device's AES key + IV from its flash over SWD before you can use it. That's definitely not super easy for a beginner. A friendlier extraction utility may come later; for now SWD is the only path.

Status

Pre-MVP, but functional on one tested device. The protocol layer has ~83 unit tests, and the HA glue has been exercised end-to-end against a live device. Per-meter behaviour will vary — see the "Discovering your meter's registers" section below.

What you get

Entity What it shows
sensor.<name>_battery_voltage CR2032 voltage, scaled from the device's ADC channel
sensor.<name>_serial_number u32 integer from the device's identity blob (cmd 0x87)
sensor.<name>_ble_mac The BLE MAC the device advertises with
sensor.<name>_last_seen UTC timestamp of the most recent successful frame
sensor.<name>_connection_state One of disconnected/connecting/handshaking/authenticated/draining/cooling/sleeping
sensor.<name>_rx_frames Total BLE notifications received this session
sensor.<name>_rx_errors Frame-level errors (CRC, framing)
sensor.<name>_rx_cipher_rejections Times the device returned the canned 0xFF 0x01 rejection
sensor.<name>_meter_reads_succeeded Device-side counter (succeededTotal from cmd 0x36). Non-zero = the device has talked to a meter.
sensor.<name>_meter_reads_failed Device-side counter
sensor.<name>_meter_day_cycles_completed Device-side counter
sensor.<name>_configured_meter_protocol The protocol (IEC / SML / Blink / DLMS) the integration last sent to the device via cmd 0x14. unknown if you've left it at "Leave unchanged".
sensor.<name>_detected_meter Result of the last Auto-detect meter button press.
button.<name>_poll_now Triggers an immediate session — refresh all sensors right now, including a brief listen for live meter pushes.
button.<name>_auto_detect_meter Asks the device to probe the optical port (cmd 0x19). Disabled until the device has reported successful meter reads at least once.

Plus, once a meter is attached and pushes data, the integration auto-creates per-register sensors as it discovers them:

Entity What it shows
sensor.<name>_meter_register_<N> Raw u32 value for OBIS register N (where N is the device's internal dataType)
sensor.<name>_meter_register_<N>_timestamp Block timestamp from the matching cmd 0x25 header

The mapping from <N> (the device's dataType) to standard OBIS codes is meter-dependent — see Discovering your meter's registers below.

Requirements

  • Home Assistant 2024.6 or newer
  • A Bluetooth source HA can use: either a USB BLE adapter on the host, or an ESPHome bluetooth_proxy node in range of the OneMeter device. Through-proxy is the tested configuration.
  • Your OneMeter device's mobKey and IV16 bytes each, hex — extracted from the device's flash. See Extracting credentials below. This is the hardest part of installation; the integration cannot work without it.

Installation

Via HACS

  1. Add this repository as a custom integration in HACS: HACS → Integrations → ⋮ → Custom repositories → URL: this repo's URL, Category: Integration.
  2. Search for OneMeter in HACS Integrations, install.
  3. Restart Home Assistant.
  4. Settings → Devices & Services → Add Integration → OneMeter.

Manual

git clone https://github.com/grappeq/onemeter-ha-integration.git
cp -r onemeter-ha-integration/custom_components/onemeter \
      /path/to/your/homeassistant/config/custom_components/
# restart HA

Configuration

After install, HA should auto-discover any OneMeter device advertising within range of a configured Bluetooth source. The discovery card asks for the device's AES key and IV (each 32 hex chars — colons / spaces are OK and stripped), plus an optional meter protocol override.

Meter protocol options:

Setting Effect
Leave unchanged (default, safe) Integration never sends cmd 0x14 — device keeps whatever protocol was set at registration
IEC 62056-21 mode D Sends cmd 0x14 [0x01, 0]writes to device flash
SML cmd 0x14 [0x01, 1]
Blink (LED pulse) cmd 0x14 [0x01, 2]
DLMS cmd 0x14 [0x01, 3]

Selecting anything other than "Leave unchanged" tells the integration to write the device's flash on the next poll. Changeable later via Configure on the integration page.

Configurable options (after install)

Settings → Devices & Services → OneMeter → Configure

Option Range Default Notes
Poll interval (seconds) 300 – 21600 3600 (1 h) Shorter intervals significantly shorten battery life and may trigger the device-side cooldown more often.
Meter protocol as above Leave unchanged Changing this triggers a flash write on the next session.

Extracting credentials

The integration needs your device's per-device AES key + IV (16 bytes each). These were written into the OneMeter's flash by the manufacturer's cloud during the device's initial registration with the OneMeter mobile app. They aren't available anywhere outside the device itself, so you have to read them out over SWD.

A helper script is provided at tools/extract_credentials.py. See tools/EXTRACTING_CREDENTIALS.md for the full step-by-step procedure, including how to wire up SWD, how to run OpenOCD, and how to recover if the defaults don't match your firmware revision.

⚠️ Untested: the script has been derived from analysis of one specific device's firmware but has not yet been run end-to-end against a live device. If you try it, please file an issue with your results — both successes and failures are useful data.

In short, the procedure is:

  1. Open the device to expose the nRF51822's SWD pads.
  2. Wire a SWD programmer (CMSIS-DAP, ST-Link, J-Link, Black Magic Probe — anything OpenOCD supports).
  3. Start OpenOCD with an appropriate target/nrf51.cfg.
  4. Run python tools/extract_credentials.py. The script halts the CPU, reads the BLE MAC + mobKey + IV using a CRP-bypass gadget, resumes the CPU, and prints the values.
  5. Paste the BLE MAC, mobKey, and IV into the integration's config flow.

Opening the device, soldering to debug pads, and using a SWD programmer are non-trivial. If you've never done embedded work before, find a friend who has.

Known limitations

Device-side post-session "cooldown"

After every successful session ends, the OneMeter device enters a state where it refuses the next BLE connection for some period of time. We don't fully understand the mechanism (see the reverse- engineering notes for details — multiple suspected gates at both the application-cmd layer and the SoftDevice BLE-stack layer; SWD reset is the only reliable manual clear).

Practical impact:

  • At the default 1-hour poll cadence the device appears to be stable in field testing. Every poll succeeds.
  • At cadences shorter than ~10 min the integration will frequently hit this and recover via exponential backoff — but you'll see reject counts climb.
  • The integration handles this gracefully: keeps retrying with backoff capped at 5 min. After 10 consecutive failed logins it surfaces a persistent notification suggesting you wait for the device to recover. It will NOT trigger HA's "Reauth needed" flow on this basis — the 0xFF 0x01 rejection is the same regardless of cause.

If the integration appears truly stuck (notification stays up for a day), the credentials may genuinely be wrong — open Configure and re-enter them.

Single-session-per-power-cycle for short intervals

In practice, polling more often than ~5–10 min will be unreliable because of the above. Stick with 30 min or longer for stable operation. The default 1 h is the recommended setting.

Discovering your meter's registers

When you first connect a meter and press Poll now, the integration opens a brief drain window listening for live meter data. As it arrives, new sensor.<name>_meter_register_<N> entities are created on the fly — one per dataType (the device's internal OBIS register identifier).

The <N> to standard-OBIS mapping is meter-dependent. For our reference (an Apator SK 16-072 MI-003, Polish 3-tariff residential):

OBIS (meter LCD) What it is
15.8.0 Total active energy across all tariffs (kWh)
15.8.1 / 15.8.2 / 15.8.3 Energy per tariff
0.9.1 / 0.9.2 Internal clock / date
0.2.2 Current tariff index

You'll need to correlate the dataType integers that appear as sensors with the values shown on your meter's display to build the mapping for your specific model. Once you know the mapping you can customise the entities in HA (rename, set device_class/state_class via the entity-customisation UI, hide the ones you don't care about).

Troubleshooting

"Discovered device" card doesn't appear

  • Confirm a Bluetooth source is configured in HA and reaches the OneMeter. Settings → Devices & Services → Bluetooth should show at least one scanner; the OneMeter should appear in any nearby-BLE list.
  • The device advertises as OM <4 digits> (e.g. OM 6863) with manufacturer ID 0xFFFF. The integration's discovery matcher keys off both.

Battery sensor stays unknown

  • The first poll hasn't finished yet — wait ~30 s post-discovery.
  • If connection_state stays in cooling/connecting: see the cooldown section.

"OneMeter — connection stuck" persistent notification

  • The device has rejected ≥ 10 consecutive login attempts. Recovery is usually time-based; the integration keeps retrying. If it never recovers within a day, the AES key / IV may be wrong — re-enter them via Configure.

Per-register sensors don't appear

  • Confirm sensor.<name>_meter_reads_succeeded > 0. If it stays at zero with the meter physically connected, the device isn't reading the meter — check optical-port alignment, or try setting the meter protocol explicitly (config option).
  • Press Poll now explicitly — the drain phase is when most live data is captured.
  • Per-register sensors are only created on first sighting and are disabled by default for any dataType we don't recognise. Re-press Poll now after enabling them.

Diagnostics

Settings → Devices & Services → OneMeter → ⋮ → Download diagnostics — produces a JSON dump of all state with the key/IV redacted. Safe to attach to bug reports.

Development

git clone <this repo>
cd onemeter-ha-integration
python3 -m venv .venv && . .venv/bin/activate
pip install pytest cryptography
python -m pytest

The protocol layer in custom_components/onemeter/protocol/ is pure Python — no HA imports, no BLE imports. Run the test suite without an HA instance or a real device.

Layout:

  • custom_components/onemeter/protocol/ — wire-protocol layer (cipher, framing, decoders, session state machine). Standalone.
  • custom_components/onemeter/coordinator.py — owns the BLE connection lifecycle. Drives OneMeterSession with bytes.
  • custom_components/onemeter/{sensor,button,config_flow}.py — HA entity platforms + the install / configure flow.
  • tests/ — pytest, against synthetic vectors derived from documented protocol observations. No live device required for the test suite.