TIA Tools

Some add-ins I've created for TIA Portal V20 that might be useful for others or as examples for developing their own.

The functions I've implemented are:

  • Prepare Go-Online settings for G120-drives
  • Export of I/O map for all devices, i.e. you can see the address space occupied by all devices
  • Export/import IP addresses and PROFINET device names

Installation

If you just want to use the add-in yourself, copy the bin\debug\TiaTools.addin file to the Add-ins folder of your TIA installation.

NOTICE: Be cautious. I take no responsibility if you mess up your TIA projects with this. USE AT YOUR OWN RISK!

Example project

This is the HW of the example project used to showcase the addin. The generated files can be inspected under docs/UserFiles.

docs/example_proj.png

Online prepare

If you have to go online on multiple G120 drives, you need to select the connection setup for each individual drive, i.e. profinet, network adapter and target port.

With this add-in, you can select all drives in the project tree that you wish to go online with, and it will ask for the settings to apply to all drives. After running the add-in, TIA remembers the settings, and the Go-Online button will work.

Export I/O map for each device

Sometimes one wants to get an overview of which hardware uses what address space.

This addin creates an XML-file in the UserFiles directory of the project.

As an example, here is the address configuration of one node in the project:

It can also handle drive telegrams, here is one of the G120C-drives

<?xml version="1.0" encoding="utf-8"?>
<AddressEntries xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <AddressEntry>
    <Path>ET 200SP station_1/DI 8/DI 8/Input</Path>
    <StartAddr>10</StartAddr>
    <Length>1</Length>
  </AddressEntry>
  ...
  <AddressEntry>
    <Path>SINAMICS G_1/AsyncDrive1/MainTelegram Nr 1/Input</Path>
    <StartAddr>258</StartAddr>
    <Length>4</Length>
  </AddressEntry>
  <AddressEntry>
    <Path>SINAMICS G_1/AsyncDrive1/MainTelegram Nr 1/Output</Path>
    <StartAddr>258</StartAddr>
    <Length>4</Length>
  </AddressEntry>
</AddressEntries>

Export/Import IP-addresses

As far as I'm aware, it is not possible to show a list of all IP addresses in a given network or project; you must click on each HW device and check its configuration.

This gets boring quickly, so with this add-in you can export and import all IP-adresses in the entire project, if you want to make changes you can then re-import them and the IP-adresses will be updated.

Please note that there are two PROFINET device names in TIA Portal: a clean name, which is allowed to contain illegal characters, and the actual name, that been converted from the clean name.

<?xml version="1.0" encoding="utf-8"?>
<IpAddrEntries xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <IpAddrEntry>
    <path>S7-1500/ET200MP station_1/PLC/PROFINET interface_1</path>
    <deviceName>S7-1500/ET200MP station_1</deviceName>
    <ipAddress>192.168.0.1</ipAddress>
    <profinetDeviceName>plc.profinetxainterfacexb13a48</profinetDeviceName>
    <profinetCleanDeviceName>plc.profinet interface_1</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>S7-1500/ET200MP station_1/PLC/PROFINET interface_2</path>
    <deviceName>S7-1500/ET200MP station_1</deviceName>
    <ipAddress>192.168.1.1</ipAddress>
    <profinetDeviceName>plc.profinetxainterfacexb23b08</profinetDeviceName>
    <profinetCleanDeviceName>plc.profinet interface_2</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>S7-1500/ET200MP station_1/PLC/PROFINET interface GBIT_3</path>
    <deviceName>S7-1500/ET200MP station_1</deviceName>
    <ipAddress>192.168.2.1</ipAddress>
    <profinetDeviceName>plc.profinetxainterfacexagbitxb34a07</profinetDeviceName>
    <profinetCleanDeviceName>plc.profinet interface gbit_3</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>HMI2/HMI2.IE_CP_1/PROFINET Interface_1</path>
    <deviceName>HMI2</deviceName>
    <ipAddress>192.168.0.8</ipAddress>
    <profinetDeviceName>hmi2.profinetxainterfacexb10656</profinetDeviceName>
    <profinetCleanDeviceName>hmi2.profinet interface_1</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>HMI1/HMI1.IE_CP_1/PROFINET Interface_1</path>
    <deviceName>HMI1</deviceName>
    <ipAddress>192.168.0.7</ipAddress>
    <profinetDeviceName>hmi1.profinetxainterfacexb1f9b2</profinetDeviceName>
    <profinetCleanDeviceName>hmi1.profinet interface_1</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>SINAMICS G_1/AsyncDrive1/PROFINET interface</path>
    <deviceName>SINAMICS G_1</deviceName>
    <ipAddress>192.168.0.9</ipAddress>
    <profinetDeviceName>asyncdrive1</profinetDeviceName>
    <profinetCleanDeviceName>asyncdrive1</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
    <path>ET 200SP station_1/DistIO1/PROFINET interface</path>
    <deviceName>ET 200SP station_1</deviceName>
    <ipAddress>192.168.0.2</ipAddress>
    <profinetDeviceName>distio1</profinetDeviceName>
    <profinetCleanDeviceName>distio1</profinetCleanDeviceName>
  </IpAddrEntry>
  <IpAddrEntry>
  <IpAddrEntry>
    <path>ET 200eco station_2/DistNode2/PROFINET interface</path>
    <deviceName>ET 200eco station_2</deviceName>
    <ipAddress>192.168.0.5</ipAddress>
    <profinetDeviceName>distnode2</profinetDeviceName>
    <profinetCleanDeviceName>distnode2</profinetCleanDeviceName>
  </IpAddrEntry>
  ...
</IpAddrEntries>

Create an empty add-in project

Here is some information if you want to create your own add-in from scratch.

Information from Siemens:

After installing build tools, I only use VS Code and the terminal.

In the desired project location run:

  1. dotnet new addin-project -P TiaAddin -N TiaAddin

  2. dotnet new addin-project-tree-menu -P TiaAddin -N TiaAddin

  3. Check correct TIA version in csproj-file,

One example from the generated project files, here it says V19, I simply replaced it with V20

<HintPath>@(TiaPortalLocation)\PublicAPI\V19.AddIn\Siemens.Engineering.AddIn.dll</HintPath>

New

<HintPath>@(TiaPortalLocation)\PublicAPI\V20.AddIn\Siemens.Engineering.AddIn.dll</HintPath>

Also in the Config.xml

<PackageConfiguration xmlns="http://www.siemens.com/automation/Openness/AddIn/Publisher/V19">
<PackageConfiguration xmlns="http://www.siemens.com/automation/Openness/AddIn/Publisher/V20">
  1. Try to build, run Ctrl+Shift+P in VS Code and select Run build task

If it worked, you should end up with an add-in in the bin/debug folder that you can drag into C:/Programs/**TIA INSTALL FOLDER**/Add-ins.

About

Some simple Addins for Siemens TIA Portal