Solis Monitor

Monitoring solution for Solis inverters using Modbus TCP/RTU. Polls register data, stores it in SQLite, and exposes it via a web API, frontend dashboard and Prometheus metrics.

solism3 solism1 solism2

API

After starting, the API Docs are available at /docs.

Health Check

A health check endpoint is available at /health.

Metrics

If enabled, Prometheus metrics are exposed at /metrics.

Configuration

Copy config.yaml and adjust settings. All options can be overridden via environment variables using the SOLIS_ prefix (e.g., SOLIS_MODBUS_HOST=192.168.1.200).

Example Configuration

# Solis-Monitor Configuration
app:
  debug: INFO      # DEBUG, INFO, WARN, ERROR, FATAL
  port: 8080
  timeout: 30s

poller:
  interval: 30s
  block_attempts: 3
  block_retry_delay: 1s
  block_interval: 0s
  poll_timeout: 30s

modbus:
  type: tcp
  host: 192.168.2.151
  port: 502
  timeout: 5s
  unit_id: 1
  # For RTU:
  # type: rtu
  # serial_port: /dev/ttyUSB0
  # baud_rate: 9600
  # data_bits: 8
  # stop_bits: 1
  # parity: none

storage:
  path: ./data/solis.db
  daily_retention: 87600h  # 10 years
  monthly_retention: 87600h
  yearly_retention: 87600h
  error_retention: 720h   # 30 days
  wal_mode: true
  synchronous: NORMAL
  temp_store: MEMORY

metrics:
  enabled: true

registers:
  disabled_keys: []
  # Example: disable specific registers
  # disabled_keys:
  #   - meter_total_active_power

App Settings

Option Type Default Description
debug string INFO Log level: DEBUG, INFO, WARN, ERROR, FATAL
port int 8080 HTTP server port (1-65535)
timeout duration 30s Request timeout

Poller Settings

Option Type Default Description
interval duration 30s Base interval between poll cycles
block_attempts int 3 Retry attempts per block if read fails
block_retry_delay duration 1s Delay between retry attempts for same block
block_interval duration 0s Delay between successive block reads (0 = immediate)
poll_timeout duration 30s Maximum duration for full poll cycle before aborting

Modbus Settings

Option Type Default Description
type string tcp Connection type: tcp, rtu, or rtu_over_tcp
host string 192.168.1.100 Modbus server IP/hostname (TCP only)
port int 502 Modbus server port (1-65535)
timeout duration 5s Connection/read timeout
unit_id byte 1 Modbus unit/slave ID (1-247)
serial_port string Serial port for RTU (e.g., /dev/ttyUSB0)
baud_rate int Baud rate for RTU
data_bits int Data bits for RTU (5, 6, 7, 8)
stop_bits int Stop bits for RTU (1, 2)
parity string Parity for RTU: none, even, odd

Storage Settings (SQLite)

Option Type Default Description
path string ./data/solis.db Path to SQLite database file
daily_retention duration 8760h Retention for daily energy values
monthly_retention duration 8760h Retention for monthly energy values
yearly_retention duration 8760h Retention for yearly energy values
error_retention duration 720h Retention for error/fault data (30 days)
wal_mode bool true Enable Write-Ahead Logging
synchronous string NORMAL Sync mode: OFF, NORMAL, FULL, EXTRA
temp_store string MEMORY Temp storage: DEFAULT, FILE, MEMORY
enable_migrations bool true Enable automatic schema migrations on startup
enable_backup bool true Enable database backup functionality
max_backups int 3 Maximum number of backup files to keep (0 = unlimited)
backup_interval duration 24h Interval for periodic backups

Database Maintenance

The application includes a comprehensive database lifecycle management system that automatically handles migrations, backups, and cleanup on startup.

Schema Migrations

  • Automatic Version Detection: The application tracks the current database schema version in a schema_version table
  • Forward-Only Migrations: Each version increment adds new schema changes while preserving existing data
  • Legacy Database Support: Pre-migration databases are automatically detected and marked as version 1
  • Migration Safety: Database is backed up before any migration is applied

Backup System

Automatic Backups: All backups use the same simplified format:

  • Filename format: {database}.{timestamp}.backup
  • Example: solis.db.20260627_143022.backup
  • Created at startup if database file exists (before any migration)
  • Created periodically at the interval specified by backup_interval
  • Runs in background without affecting application performance

Backup Management:

  • Automatic cleanup keeps only the most recent max_backups files
  • Old backups are removed oldest first
  • Set max_backups: 0 to disable automatic cleanup (keep all backups)
  • Backup files are stored in a backups subdirectory of the database directory

Backup Verification:

  • Each backup is verified to have the same size as the source database
  • Empty backups are rejected and deleted
  • All backup operations are logged with timestamps and file sizes

Configuration Examples

Daily backups with 7-day retention:

storage:
  enable_backup: true
  max_backups: 7
  backup_interval: 24h

Frequent backups with unlimited retention:

storage:
  enable_backup: true
  max_backups: 0  # Keep all backups
  backup_interval: 6h

Disable backup functionality:

storage:
  enable_backup: false

Disable migrations (not recommended):

storage:
  enable_migrations: false

Manual Backup Management

Backup files can be manually managed:

  • Copy: Backup files can be copied to other locations for offsite storage
  • Restore: Copy a backup file over the database file and restart the application
  • Delete: Old backups can be safely deleted (application will recreate as needed)

Migration Process

  1. Startup: Application checks database schema version
  2. Backup: If database file exists, a backup is created (regardless of migration need)
  3. Migration: If needed, pending migrations are applied in order
  4. Verification: Schema version is updated and verified
  5. Cleanup: Old backups beyond max_backups are removed
  6. Initialization: Storage is initialized with the updated schema

Troubleshooting

Application fails to start with migration error:

  • Check logs for specific error message
  • Restore from the latest backup file: cp backups/solis.db.20260627_143022.backup solis.db
  • Ensure database file has proper permissions

Backup files accumulating:

  • Increase max_backups to keep more backups
  • Set max_backups: 0 to keep all backups
  • Manually delete old backups if needed

Migrations taking too long:

  • Migration only runs when necessary (schema version mismatch)
  • Complex migrations may take time; this is normal for large databases
  • Check logs for migration progress

Metrics Settings

Option Type Default Description
enabled bool false Enable Prometheus metrics endpoint

Registers Settings

Option Type Default Description
disabled_keys []string [] Register keys to disable (exclude from polling, storage, API)

Available Registers

All registers are polled by default. Disable specific ones via registers.disabled_keys in config.

Information Registers

Key Name Address Type Scale Unit Stability
solis_model_no Solis Model No 33000 Uint16 1.0 stable
solis_dsp_version Solis DSP Version 33001 Uint16 1.0 stable
solis_hmi_version Solis HMI Version 33002 Uint16 1.0 stable
solis_protocol_version Solis Protocol Version 33003 Uint16 1.0 stable
solis_serial_number Solis Serial Number 33004 String 1.0 stable

Energy Registers

Key Name Address Type Scale Unit Stability
pv_today_energy Solis PV Today Energy Generation 33035 Uint16 0.1 kWh dynamic
pv_month_energy Solis PV Current Month Energy Generation 33031 Uint32 1 kWh dynamic
pv_year_energy Solis PV This Year Energy Generation 33037 Uint32 1 kWh dynamic
pv_total_energy Solis PV Total Energy Generation 33029 Uint32 1 kWh dynamic

PV Voltage/Current Registers

Key Name Address Type Scale Unit Stability
pv_voltage_1 Solis PV Voltage 1 33049 Uint16 0.1 V dynamic
pv_current_1 Solis PV Current 1 33050 Uint16 0.1 A dynamic
pv_voltage_2 Solis PV Voltage 2 33051 Uint16 0.1 V dynamic
pv_current_2 Solis PV Current 2 33052 Uint16 0.1 A dynamic
pv_voltage_3 Solis PV Voltage 3 33053 Uint16 0.1 V dynamic
pv_current_3 Solis PV Current 3 33054 Uint16 0.1 A dynamic
pv_voltage_4 Solis PV Voltage 4 33055 Uint16 0.1 V dynamic
pv_current_4 Solis PV Current 4 33056 Uint16 0.1 A dynamic

PV Power and Bus Registers

Key Name Address Type Scale Unit Stability
total_pv_power Solis Total PV Power 33057 Uint32 1 W dynamic

Grid Voltage/Current Registers

Key Name Address Type Scale Unit Stability
a_phase_voltage Solis A Phase Voltage 33073 Uint16 0.1 V dynamic
b_phase_voltage Solis B Phase Voltage 33074 Uint16 0.1 V dynamic
c_phase_voltage Solis C Phase Voltage 33075 Uint16 0.1 V dynamic
a_phase_current Solis A Phase Current 33076 Uint16 0.1 A dynamic
b_phase_current Solis B Phase Current 33077 Uint16 0.1 A dynamic
c_phase_current Solis C Phase Current 33078 Uint16 0.1 A dynamic
active_power Solis Active Power 33079 Uint32 1 W dynamic
reactive_power Solis Reactive Power 33081 Int32 0.1 VAR dynamic
apparent_power Solis Apparent Power 33083 Uint32 0.1 VA dynamic
grid_frequency Solis Grid Frequency 33094 Uint16 0.01 HZ dynamic

Temperature and Status Registers

Key Name Address Type Scale Unit Stability
temperature Solis Temperature 33093 Int16 0.1 C dynamic
solis_status Solis Status 33095 Uint16 1.0 dynamic

Fault Registers

Key Name Address Type Scale Unit Stability
grid_fault_status_01 Solis Grid Fault Status 01 (Bitmask) 33116 Uint16 1.0 dynamic
backup_load_fault_status_02 Solis Backup Load Fault Status 02 (Bitmask) 33117 Uint16 1.0 dynamic
battery_fault_status_03 Solis Battery Fault Status 03 (Bitmask) 33118 Uint16 1.0 dynamic
device_fault_status_04 Solis Device Fault Status 04 (Bitmask) 33119 Uint16 1.0 dynamic
device_fault_status_05 Solis Device Fault Status 05 (Bitmask) 33120 Uint16 1.0 dynamic
operating_status Solis Operating Status (Bitmask) 33121 Uint16 1.0 dynamic

Battery Registers

Key Name Address Type Scale Unit Stability
battery_voltage Solis Battery Voltage 33133 Uint16 0.1 V dynamic
battery_current Solis Battery Current 33134 Int16 0.1 A dynamic
battery_current_direction Solis Battery Current Direction 33135 Uint16 1.0 dynamic
battery_soc Solis Battery SOC 33139 Uint16 1.0 % dynamic
battery_soh Solis Battery SOH 33140 Uint16 1.0 % dynamic
battery_voltage_bms Solis Battery Voltage (BMS) 33141 Uint16 0.01 V dynamic
battery_fault_status_1_bms Solis Battery Fault Status 1 (BMS) 33145 Uint16 1.0 dynamic
battery_fault_status_2_bms Solis Battery Fault Status 2 (BMS) 33146 Uint16 1.0 dynamic
battery_power Solis Battery Power 33149 Int32 1 W dynamic

Backup Registers

Key Name Address Type Scale Unit Stability
backup_ac_voltage_phase_a Solis Backup AC Voltage Phase A 33137 Uint16 0.1 V dynamic
backup_ac_current_phase_a Solis Backup AC Current Phase A 33138 Uint16 0.1 A dynamic
household_load_power Solis Household Load Power 33147 Uint16 1 W dynamic
backup_load_power Solis Backup Load Power 33148 Uint16 1 W dynamic
ac_grid_port_power Solis AC Grid Port Power 33151 Int32 0.1 W dynamic

Battery Energy Registers

Key Name Address Type Scale Unit Stability
today_battery_charge_energy Solis Today Battery Charge Energy 33163 Uint16 0.1 kWh dynamic
today_battery_discharge_energy Solis Today Battery Discharge Energy 33167 Uint16 0.1 kWh dynamic
total_battery_discharge_energy Solis Total Battery Discharge Energy 33165 Uint32 1 kWh dynamic
total_battery_charge_energy Solis Total Battery Charge Energy 33161 Uint32 1 kWh dynamic

Grid Energy Registers

Key Name Address Type Scale Unit Stability
today_energy_imported_from_grid Solis Today Energy Imported From Grid 33171 Uint16 0.1 kWh dynamic
total_energy_imported_from_grid Solis Total Energy Imported From Grid 33169 Uint32 0.1 kWh dynamic
total_energy_fed_into_grid Solis Total Energy Fed Into Grid 33173 Uint32 0.1 kWh dynamic
today_energy_fed_into_grid Solis Today Energy Fed Into Grid 33175 Uint16 0.1 kWh dynamic
today_energy_consumption Solis Today Energy Consumption 33179 Uint16 0.1 kWh dynamic
total_energy_consumption Solis Total Energy Consumption 33177 Uint32 1 kWh dynamic

Household Load Registers

Key Name Address Type Scale Unit Stability
household_load_today_energy Solis Household Load Today Energy 33586 Uint16 0.1 kWh dynamic
household_load_year_energy Solis Household Load Year Energy 33582 Uint32 1 kWh dynamic
household_load_month_energy Solis Household Load Month Energy 33584 Uint32 1 kWh dynamic
household_load_total_energy Solis Household Load Total Energy 33580 Uint32 1 kWh dynamic

Backup Load Registers

Key Name Address Type Scale Unit Stability
backup_load_today_energy Solis Backup Load Today Energy 33596 Uint16 0.1 kWh dynamic
backup_load_total_energy Solis Backup Load Total Energy 33590 Uint32 1 kWh dynamic
backup_load_year_energy Solis Backup Load Year Energy 33592 Uint32 1 kWh dynamic
backup_load_month_energy Solis Backup Load Month Energy 33594 Uint32 1 kWh dynamic

Meter Registers

Key Name Address Type Scale Unit Stability
meter_ac_voltage_a Solis Meter AC Voltage A 33251 Uint16 0.1 V dynamic
meter_ac_current_a Solis Meter AC Current A 33252 Uint16 0.1 A dynamic
meter_ac_voltage_b Solis Meter AC Voltage B 33253 Uint16 0.1 V dynamic
meter_ac_current_b Solis Meter AC Current B 33254 Uint16 0.1 A dynamic
meter_ac_voltage_c Solis Meter AC Voltage C 33255 Uint16 0.1 V dynamic
meter_ac_current_c Solis Meter AC Current C 33256 Uint16 0.1 A dynamic
meter_active_power_a Solis Meter Active Power A 33257 Int32 0.1 W dynamic
meter_active_power_b Solis Meter Active Power B 33259 Int32 0.1 W dynamic
meter_active_power_c Solis Meter Active Power C 33261 Int32 0.1 W dynamic
meter_total_active_power Solis Meter Total Active Power 33263 Int32 1.0 W dynamic

Computed Registers

Note: These registers are computed/virtual (Address = 0) and do not exist in the inverter's Modbus interface. They are calculated from other registers and stored in the database. Values may be inaccurate if source registers are incorrect or if the calculation logic has changed.

Key Name Source Scale Unit Stability
today_grid_energy Today Grid Energy (Net) total_energy_fed_into_grid - total_energy_imported_from_grid 1 kWh dynamic
total_grid_energy Total Grid Energy (Net) total_energy_fed_into_grid - total_energy_imported_from_grid 1 kWh dynamic
energy_consumption_month_energy Energy Consumption Month Energy (Computed) Sum of today_energy_consumption daily values 1 kWh dynamic
energy_fed_into_grid_month_energy Energy Fed Into Grid Month Energy (Computed) Sum of today_energy_fed_into_grid daily values 1 kWh dynamic
energy_imported_from_grid_month_energy Energy Imported From Grid Month Energy (Computed) Sum of today_energy_imported_from_grid daily values 1 kWh dynamic
battery_discharge_month_energy Battery Discharge Month Energy (Computed) Sum of today_battery_discharge_energy daily values 1 kWh dynamic
battery_charge_month_energy Battery Charge Month Energy (Computed) Sum of today_battery_charge_energy daily values 1 kWh dynamic
month_grid_energy Month Grid Energy (Net, Computed) energy_fed_into_grid_month_energy - energy_imported_from_grid_month_energy 1 kWh dynamic
energy_consumption_year_energy Energy Consumption Year Energy (Computed) Sum of today_energy_consumption daily values 1 kWh dynamic
energy_fed_into_grid_year_energy Energy Fed Into Grid Year Energy (Computed) Sum of today_energy_fed_into_grid daily values 1 kWh dynamic
energy_imported_from_grid_year_energy Energy Imported From Grid Year Energy (Computed) Sum of today_energy_imported_from_grid daily values 1 kWh dynamic
battery_discharge_year_energy Battery Discharge Year Energy (Computed) Sum of today_battery_discharge_energy daily values 1 kWh dynamic
battery_charge_year_energy Battery Charge Year Energy (Computed) Sum of today_battery_charge_energy daily values 1 kWh dynamic
year_grid_energy Year Grid Energy (Net, Computed) energy_fed_into_grid_year_energy - energy_imported_from_grid_year_energy 1 kWh dynamic

Running

Docker (recommended)

# Production
docker-compose up -d

# Development (builds from source)
docker-compose -f docker-compose.dev.yaml up --build

Both mount ./data for persistence and ./config.yaml for configuration.

---
services:
  app:
    image: ghcr.io/dombyte/solis:latest
    volumes:
      - ./data:/app/data
      - ./config.yaml:/app/config.yaml:ro
    ports:
      - "8080:8080"
    restart: unless-stopped
    environment:
      - TZ=Europe/Berlin
    healthcheck:
      test: ["CMD", "httpcheck", "http://localhost:8080/health"]
      interval: 30s
      timeout: 10s
      retries: 3

Local

go run ./cmd
# or build first
go build -o solis ./cmd && ./solis

Development

# Build
go build -o solis ./cmd

# Run tests
go test ./...

# Format code
go fmt ./...

# Update dependencies
go mod tidy

Frontend

cd frontend
npm install
npm run dev

About

Monitoring for Solis inverters using Modbus TCP/RTU

Topics

Resources

License