Contributor

-Significant overhaul of unit-handling in HPWHsim. Physical quantities are transmitted to/from HPWHsim as objects with a units property. A parameter such as temperature can be specified directly in a function call to HPWHsim using the form {20., Units::C}. A returned quantity is converted to a double of appropriate dimensions using a form such as hw_pHPWH->getTankHeatContent()(Units::kWh).

-Several cse regression tests failed as a result of slight differences in physical constants.