Check a building against the National Energy Code of Canada for Buildings (NECB) 2020 or 2025, Part 8 performance path — Article 8.4.1.2, the proposed-versus-reference determination.
You give it an OpenStudio model. It builds the reference building for you, simulates both in EnergyPlus, applies the Part 8 rules, and writes a self-contained HTML report you can hand to an authority having jurisdiction, plus a complete audit trail of every decision it made and the code article behind each one.
btap-compliance my-building.osm --epw toronto.epw
------------------------------------------------------------------
site kWh kWh/m2/yr area m2
Proposed 2,725 3.4 800.0
Reference 3,025 3.8 800.0
Margin 300.0 9.9% under target Tier 1
Unmet hours heating 0.8 / 24.8 h cooling 13.5 / 0.0 h
------------------------------------------------------------------
VERDICT: COMPLIANT (NECB 2020, Division B, Article 8.4.1.2)
------------------------------------------------------------------
This is a compliance-checking tool, not a design tool. It tells you whether a model passes and shows its work. It does not make a non-compliant building compliant, and it does not repair a model that is not ready to be checked.
Licensed LGPL-3.0-or-later — see LICENSE.
| If you want to… | Go to |
|---|---|
| install it | Installing |
| install it on Windows | Installing on Windows |
| run your first check | Running a check |
| understand what it decided and why | Reading the results |
| know which code articles are covered | What is implemented |
| know where it makes a judgement call | Decisions and assumptions |
| know what it does not do | Known limits |
| work on the code itself | docs/DEVELOPERS.md |
pip install "canmet-btap[tbd]"That gives you the btap-compliance command, and on Windows or Linux
EnergyPlus comes with it — there is nothing else to install, no separate
download, and no first-run surprise.
- You need Python 3.11 or newer. The OpenStudio SDK and the EnergyPlus engine both arrive as ordinary dependencies.
- The engine is included on Windows x86-64 and Linux x86-64 (glibc 2.35 or
newer) — that is Ubuntu 22.04 and later, RHEL 9 and later, and anything
comparable. It is the exact EnergyPlus build this tool is verified against,
shipped as the
canmet-energypluswheel. - On macOS, and on musl or older-glibc Linux, the engine is downloaded and
version-verified on first use instead. If that machine is offline or behind
a TLS-intercepting proxy, point at an engine you already have with
BTAP_ENERGYPLUS, or at a downloaded archive withBTAP_ENERGYPLUS_ARCHIVE. [tbd]adds thermal-bridging support (Article 3.1.1.7). Without it the run still works and says so loudly in the audit, rather than quietly leaving bridging out.
Prefer to work from source? git clone https://github.com/canmet-energy/btap.git
then cd btap/python && pip install '.[tbd]'.
Not a Python user? Download btap-compliance-setup-<version>.exe from the
releases page and run it. You
need nothing else on the machine — not Python, not OpenStudio, not EnergyPlus.
The installer carries its own Python 3.12, OpenStudio 3.11.0 and EnergyPlus 25.2.0, so it cannot disturb anything you already have.
- It installs per user and needs no administrator rights, so there is no UAC prompt and it works on a locked-down machine.
- It writes nothing to system folders or the registry, and nothing to
PATHunless you ask. - Everything lives in one directory you can delete.
Then open NECB Compliance (console) from the Start menu and type
btap-compliance --help, or double-click samples\run-demo.cmd for a worked
example.
btap-compliance MODEL.osm --epw weather.epwPass the weather explicitly with --epw path/to/file.epw. A matching .ddy
must sit beside it, because the sizing runs need design days. Canadian CWEC
files come from climate.onebuilding.org.
--city toronto is a shortcut for weather that ships with the Windows
installer; btap-compliance --list-cities shows what your install carries.
A pip install carries none, so use --epw there.
Expect it to take 40–90 minutes. A determination is four EnergyPlus simulations — proposed sizing, proposed annual, reference sizing, reference annual — plus up to three more if Article 8.4.1.2.(5) has to increase capacities to meet the unmet-hours limits. Progress is printed as each phase starts.
--quick shortens the run to a single week so you can watch the pipeline work in
a few minutes. It is not a code determination and the tool refuses to report
a verdict for it — 8.4.1.2 requires a simulated year.
Useful if you are scripting this over many models:
0 |
compliant |
1 |
not compliant — a verdict, not an error |
2 |
bad input (missing file, bad option) |
3 |
the model was rejected before any simulation ran — see below |
4 |
the simulation failed |
5 |
internal error |
6 |
no determination made (--quick, or --simulate sizing/none) |
The reference building can only be generated when every space type resolves against the NECB catalog, so the tool checks that before spending an hour simulating, and names every type it could not match along with the closest catalog entries.
Models from BTAP or openstudio-standards already carry the right tags. Models built by hand in the OpenStudio Application usually do not. Two ways forward:
- tag the model — set
standardsBuildingTypeandstandardsSpaceTypeon each space type to NECB catalog names; or - let the tool apply NECB space-use loads for you:
--space-type "Space Function/Office enclosed > 25 m2"for a uniform building, or--space-type-map mymap.jsonfor a per-space mapping.
Every run writes four things to the output directory:
| File | What it is |
|---|---|
compliance_report.html |
the AHJ-facing report — verdict, both buildings side by side, an article-by-article checklist, floor plans, HVAC schematics. One self-contained file. |
audit.txt |
every decision in order, each tagged with the code article behind it |
audit.json |
the same, machine-readable |
report.json |
the energy results and the determination |
Read audit.txt when you want to know why. Each line carries the article
it applied and, where the code needed interpreting, the decision id (D-XX)
that records how we read it. Warnings are never silent, and violations are
SHOUTED so they are greppable.
Both files survive a crash: if a simulation fails, the audit trail up to that point is still written.
Coverage is generated from the code, not hand-maintained:
- NECB_COVERAGE.md — every article each rule domain declares, with its status and its gaps. The filename is retained for continuity with the pre-R6 evidence record.
- NECB_8_4_COVERAGE.html — Section 8.4 article by article, down to sentence and clause text, showing where each is applied in the code. One collapsible part per edition, each in its own article numbering — 2020's 8.4.4 is the reference building where 2025's is the EUI path, so nothing is renumbered across editions.
As generated today, the rollup reports (the coverage document itself opens with this table, then a collapsible section per edition in that edition's own article numbering):
| NECB 2020 | NECB 2025 | |
|---|---|---|
| Implemented | 63 | 65 |
| Partial (warns every run) | 27 | 28 |
| Not implemented (warns every run) | 4 | 4 |
| Satisfied by construction (clone) | 3 | 3 |
| Host / other-package scope | 12 | 12 |
| Field / document verification (modeller scope, does not warn) | 10 | 10 |
| Total entries | 119 | 122 |
Counts are per-edition rows, and coverage is declared per sentence where the underlying work distinguishes sentences — so one article can contribute several rows. The not-implemented rows are individual sentences — the multi-energy capacity ratios (heating (5), cooling (4)) and two supply-air fan clauses (8.4.4.18.(5)-(6)) — not whole articles; every article is at least partially implemented.
Every partial and not-implemented entry warns on every run and appears in the audit, so nothing in this list is hidden from a reviewer. These counts come from the coverage document itself — follow the link for the current figures and, more usefully, for each partial article's specific gap.
Where the code needs interpreting, the interpretation is written down rather than buried in the source. 84 decisions are recorded in necb_decisions.md — 40 of them active at runtime, tagging the audit entries they govern.
A decision records what the code says, how we read it, what we rejected, and why. They cover things such as which reference system a given proposed system maps to, how the auxiliary-fuel election is decided for a heat pump, and how purchased energy is represented.
The HTML report's "Decisions and assumptions applied" appendix lists the ones that actually fired in your run — so a reviewer sees the judgement calls that affected this building, not all 84.
Stated plainly, because a compliance tool that hides these is worse than useless:
- It does not make a model compliant. It checks and explains.
- A model must be simulate-able and NECB-tagged before it can be checked — see exit 3 above.
--quickis never a determination. Article 8.4.1.2 requires a simulated year.- Multi-energy capacity ratios (8.4.4.9.(5) / 8.4.4.10.(4)) are not modelled. A plant drawing on more than one energy source passes into the reference unchanged rather than being apportioned.
- No article is wholly unimplemented. Four individual sentences are — the multi-energy capacity ratios (8.4.4.9.(5) and 8.4.4.10.(4)) and two supply-air fan clauses (8.4.4.18.(5)-(6)) — and each is named as its own row in the coverage document and warns on every run.
- Seven requirements are verified outside the model, not by it — the whole-building air-leakage test (3.2.4.1, 3.2.4.2), service-water piping insulation and heat trace (6.2.3.1, 6.2.4.3), fixture flow limits (6.2.6), radiant space-temperature control, and the choice of climatic data set. These are code requirements on the building; an energy model has nothing to inspect. They are declared on every run so a reviewer sees them accounted for rather than absent.
- Vintages 2020 and 2025 only. 2011–2017 are not supported.
- Costing is off unless you supply priced data. The installer ships no
priced cost tables;
--costs-csvtakes your own.
The full, current list — including every partial article's specific gap — is in the coverage documents linked above. They are regenerated from the code and checked in CI, so they cannot drift from what the software actually does.
The installer includes worked examples in samples\: one building with ten
different HVAC systems, plus six cases chosen to show the reference-building
rules doing something visible — purchased heating becoming a gas-fired boiler,
the storey count changing which reference system is selected, a staged
mixed-fuel plant, and the heat-pump auxiliary-fuel election.
Each is described in samples\README.txt with the article it exercises.
The product is one Python distribution, canmet-btap (import package btap),
with five subpackages and one-way dependencies:
| Subpackage | Responsibility |
|---|---|
btap.audit |
shared audit log and article-coverage evidence; SDK-free |
btap.modeling |
generic OpenStudio model authoring, geometry, constructions, and HVAC topology builders |
btap.costing |
capital costing and the licensed-data boundary; priced data is runtime-injected, never redistributed |
btap.codes |
code families (btap.codes.necb — NECB 2020/2025): rules, reference-building pipeline, determination, coverage, report, and CLI |
btap.simulation |
local EnergyPlus execution and the HBIX remote backend |
The former product Ruby gems were retired by D-84. Ruby remains only in
legacy_pin/ and verification/oracle/ to run the pinned
openstudio-standards oracle; it is verification infrastructure, not a second
product implementation. docs/README.md explains the decision
and evidence registers.
See docs/DEVELOPERS.md — the package contract, requirements, devcontainer, MCP configuration, test suites, frozen scenarios, and live-oracle gates.