Controls MSpa hot tubs via the MSpa Cloud API.
Supports heating, filter, UVC, bubble and jet control with full automation via time windows, PV surplus and frost protection.
- 🌡️ Read/set water temperature & target temperature (20–42 °C, 0.5 °C steps) – values outside this range are rejected with a log warning
- 🔘 Turn heater, filter, bubble, jet, ozone and UVC on/off
- 🔗 Auto-dependency management:
- Switching heater ON → automatically starts the filter pump first (device requirement)
- Switching UVC ON → automatically starts the filter pump first (device requirement)
- Switching filter OFF → automatically stops heater, UVC and bubble first (API requirement)
- 📊 Automatic heating & cooling rate calculation (°C/h, moving EMA average)
→ requiresheat_state = 2 or 3orheater = on, and a minimum 3-minute measurement window - ⏱️ ETA as
hh:mmuntil target temperature is reached (status.heat_target_temp_reached)
→ calculated fromcomputed.heat_rate_per_hourand the target/water temperature delta; capped at 48 h,00:00when not heating - ⚡ Power failure detection with optional state restoration
- 🌍 3 server regions: Europe (ROW), USA, China
- 🔒 Rate limiter (max. 2.5 requests/second)
- 🚀 Rapid polling after commands (1-second interval for 15 s) – running poll timer is cancelled immediately so ACK arrives within ~2 s
- ⏰ Unlimited configurable time windows (weekday selection, start/end time, overnight ranges supported)
- 📋 Per-window control of heating (with target temperature), filter pump and UVC
- 🔗 UVC only active when filter pump is running
- 🕐 Configurable pump follow-up time after window ends (pump keeps running N minutes)
- ALL-OFF window: set
action_filter = falseANDaction_heating = false→ the adapter actively shuts down heater, UVC and filter when the window starts
→ use this to force everything off at a specific time (e.g. 22:00–06:00) - PV windows are only activated when the current time and weekday match the configured window
- ☀️ Automatic activation when PV surplus exceeds configurable threshold (W)
- 🌥️ Configurable cloud-protection delay before deactivation (minutes)
- 📉 Hysteresis to prevent rapid on/off switching
- 📋 Independent of time window control – can be combined
computed.pv_active–trueonly when a PV-enabled time window is currently open (correct day + time) AND surplus is above threshold
→ automatically set tofalsewhen the time window ends or at night (no manual reset needed)computed.pv_deactivate_remaining– remaining minutes of the cloud-protection delay (live countdown)- Staged deactivation – when surplus drops, the system shuts down in steps:
- Heater OFF (immediately) – if firmware already reached target temperature (
heat_state=4), the API call is skipped - UVC OFF (after configurable delay) – but only when the daily UVC minimum runtime is reached; otherwise UVC keeps running until the minimum is met
- Filter OFF (after another delay) – but only if firmware is not actively heating (
heat_state 2/3)
- Heater OFF (immediately) – if firmware already reached target temperature (
- If PV surplus recovers during staged deactivation → all timers cancelled, previously turned-off devices re-activated
- 📅 Define a season window (DD.MM – DD.MM) in the adapter settings
- Season can be toggled at runtime via
control.season_enabled(e.g. from VIS) – survives adapter restarts - Outside the season: polling continues, all automation is paused (time windows, PV)
- When
season_enabled = false: only frost protection (winter mode) is still allowed to run
- ❄️ Protects the hot tub from freezing when left outdoors in winter
- Activates heater + filter automatically when water temperature falls to or below the configured frost threshold (°C)
- Deactivates again when temperature rises 3 °C above the threshold (hysteresis)
- Enabled/disabled via
control.winter_mode(e.g. from VIS) – survives adapter restarts - Frost threshold configured in the adapter settings (Admin → Time Control tab)
- Sends a Telegram notification when frost protection activates or deactivates
- Runs independently of
season_enabled– frost protection works even when the season is disabled
season_enabledvs.winter_mode– the difference:
season_enabledwinter_modeResult truefalseTime windows + PV active, no frost protection truetrueTime windows + PV + frost protection falsefalseEverything paused falsetrueOnly frost protection – all other automations paused The two flags are independent –
winter_modedoes NOT disableseason_enabled.
- 🛑 Pauses all automations (time windows, PV surplus, frost protection) with a single switch
- Set
control.manual_override = trueto pause – the adapter will no longer send any commands to the device - Optional auto-resume: set
control.manual_override_duration(minutes) before enabling – the adapter resumes automatically after the configured time (0= indefinite) - When override is disabled, all automations are immediately re-evaluated with the latest device data
control.manual_overrideis always reset tofalseon adapter restart- Typical use case: control the device via the MSpa app temporarily without the adapter interfering
- 🔦 Configure installation date and rated lifetime (operating hours) in adapter settings
- Real operating hours are counted – only while UVC is actually switched ON
- Accumulated hours are persisted across adapter restarts
status.uvc_hours_used– total accumulated UVC operating hours (writable – set manually to correct after data loss or lamp replacement)status.uvc_today_hours– UVC operating hours for today (resets at midnight)status.uvc_hours_remaining– remaining hours until rated lifetime is reached (updated every poll while UVC is ON)- Warns when lifetime is exhausted
Manual correction of
status.uvc_hours_used:
If the value shows0after data loss:
- Stop the adapter
- Set the correct value in ioBroker Admin (e.g.
120for 5 days × 24 h continuous run)- Start the adapter – it reads the persisted value and recalculates
uvc_hours_remainingimmediately
- ⏱️ Ensures UVC runs a minimum number of hours per day (configurable)
- If the daily minimum is not yet reached, the adapter automatically starts UVC (and the filter pump) at the configured ensure time
control.uvc_ensure_skip_today– skip the daily ensure for today (e.g. when manually cleaning) → automatically resets at midnight
- ⏳
control.filter_running– accumulated filter pump operating hours (persisted across restarts) control.filter_reset– momentary trigger: resets the filter runtime counter to0(e.g. after filter cartridge replacement)
- 📈 Daily kWh tracking via external energy meter datapoint
- Resets automatically at midnight
- Independent of season and time window control
- 📨 Send notifications via Telegram on:
- ☀️ PV surplus activated / deactivated
- ⏰ Time window started / ended
- 📅 Season started / ended
- 🔦 UVC lamp expiry warning
- ❄️ Frost protection activated / deactivated
- 🛑 Manual override enabled / disabled (with duration if set)
- Supports multiple recipients (comma-separated usernames)
- (arteck) add offline message
- (arteck) fix app override
- (arteck) fix pv
- (arteck) online - offline detection
- (arteck) refactoring
- (arteck) fix offline status
- (arteck) new logic for heater
- (arteck) fix heater start
- (copilot) Adapter requires node.js >= 22 now
- (arteck) optimization, automatic detection
- (arteck) fix uvc start
- (arteck) add warning as text