ecg-recoverability

Certified Reduced-Lead ECG Reconstruction — a per-feature recoverability certificate with distribution-free calibration.

Targeting the IEEE ICASSP Biomedical Signal Processing track. The certificate and every theory-validation experiment are CPU-only and fully reproducible on real public data (PTB-XL); the single generative-fabrication exhibit trains a conditional diffusion model and needs a GPU (experiments/gpu_diffusion_clean.py). Every theorem in the paper is cross-checked against Monte-Carlo simulation by the test suite before it is allowed into the manuscript.

TL;DR — Reconstructing missing ECG leads from a reduced set is an ill-posed inverse problem, and a scalar reconstruction error says nothing about which features a clinician can trust. We output, per waveform feature (P/QRS/ST/T) and per lead, a certificate of what is provably recoverable (with a closed-form conditioning κ that warns, before any reconstruction, which lead configurations can support a feature), what is statistically recoverable (distribution-free calibrated interval), and what is provably unrecoverable (flagged, held-out false-flag ≤ α). The engine is a fact the ECG has and generic inverse-problem theory does not: each waveform segment is an approximately rank-3 cardiac dipole plus a non-dipolar residual. A real conditional diffusion model, scored against a held-out recoverability oracle, shows fabrication is a choice of objective, not an accident of the network: raising the realism knob injects a growing recoverability deficit that the certificate localizes and a scalar RMSE cannot see.


Table of contents

  1. The problem in plain language
  2. The idea: three tiers of recoverability
  3. The theorem (and what is not ours)
  4. The certified estimator
  5. Results
  6. Repository layout
  7. Installation and full reproduction
  8. Data access (important under GFW)
  9. What each test proves
  10. Relation to prior work
  11. Honest limitations
  12. 中文速览
  13. Citation & license

1. The problem in plain language

A 12-lead ECG is expensive to acquire; wearables and monitors often record only one, three, or six leads. Lead reconstruction fills in the rest. Dozens of recent methods — linear, U-Net, transformer, diffusion — report a low mean-squared error (MSE) and declare success.

But a low average error certifies nothing about which features are trustworthy. A cardiologist does not read "average millivolts"; they read the P wave, the QRS complex, the ST segment, the T wave — each on specific leads. If a reconstruction gets the average right but invents an ST elevation on V2, it invents a heart attack.

Generative models are especially dangerous here, and for a principled reason. To look realistic on an ill-posed problem you must add content you cannot know (the perception-distortion tradeoff). On an image that yields a plausible-but-wrong texture; on an ECG it yields a plausible-but-wrong diagnosis.

2. The idea: three tiers of recoverability

Write reduced-lead reconstruction as an inverse problem y_S = A_S · L + noise, where L is the full 12-lead signal and A_S selects the observed leads S. Because the standard 12 leads obey exact algebra (Einthoven / Goldberger: III = II − I, aVR = −(I+II)/2, …), the operator A_S is known — we never estimate it.

For each waveform segment s ∈ {P, QRS, ST, T} the instantaneous heart potential is, to good approximation, a 3-D cardiac dipole M_s·d plus a non-dipolar residual r_s. We estimate the per-segment dipolar basis M_s ∈ ℝ^{12×3} from a population (the top-3 left singular vectors of the segment's lead covariance). This splits every reconstructed feature into three tiers:

Tier What it is Guarantee
I — recoverable the dipolar component, when S spans the dipole exact up to a closed-form noise gain κ_s(S)
II — statistical population-correlated non-dipolar content distribution-free calibrated interval
III — unrecoverable non-dipolar content independent of S (local, e.g. a fractionated QRS under one precordial electrode) any reconstruction of it is fabrication → flagged with false-flag rate ≤ α

The number κ_s(S) = ‖M_s M_{s,S}⁺‖₂ is the key object. It says geometry beats lead count: three coplanar limb leads see only 2 of the 3 dipole directions, and six frontal-plane limb leads recover the (transverse) dipole far worse than three well-chosen leads. Measured on PTB-XL QRS:

configuration κ note
Lead-I rank 1 2 of 3 dipole directions are Tier III
{I, II, V2} (spread) 3.1 well-conditioned
{V1, V2, V3} (adjacent) 4.9 spans, but worse
{I, II, III} (coplanar) 3.9×10⁵ looks like 3 leads, is really 2
limb-6 6.7×10⁴ 6 leads, all frontal-plane

3. The theorem (and what is not ours)

Theorem (per-feature dipolar recoverability). With M_{s,S} the observed rows of M_s: if rank(M_{s,S}) = 3, the population-dipolar projection of every lead is recovered by L̂_s = M_s M_{s,S}⁺ y_S with error M_s M_{s,S}⁺ n, so the error is ≤ κ_s(S)·‖n‖. If rank < 3, the unobserved dipole directions are unrecoverable at any SNR. The residual splits into a y_S-predictable (Tier II) and a y_S-independent (Tier III) part.

This is a positive guarantee — which named feature, on which lead, is recoverable and with what noise gain — that a generic inverse-problem analysis cannot produce, because it has no M. That is what makes the work non-derivative rather than "apply known UQ to ECG."

What we do not claim. The negative side — that Tier III content is unrecoverable and any estimator returns the prior mean with error ≥ Var(u) — is the standard non-identifiability limit, established in general form for inverse problems by [Iagaru & Gottschling et al., arXiv:2605.13146] and [Kim & Fridovich-Keil, arXiv:2510.10947]. We credit and use it; our contribution is the ECG-physical instantiation, the positive κ_s(S) certificate, and the clinical metering.

4. The certified estimator

  • Tier II — calibrated intervals. Group-conditional (Mondrian) conformalized quantile regression (CQR): a separate finite-sample conformal correction per group (segment, lead), so coverage holds conditional on the feature and lead, not just marginally.
  • Tier III — the flag. The hallucination energy h_{s,ℓ} is the reconstruction's energy in the certified-unrecoverable subspace. We threshold it at the one-sided (1−α) conformal quantile of h over faithful reconstructions, so the false-flag rate is ≤ α, finite-sample and distribution-free. Conformal Risk Control sets α against the clinical loss (a missed STEMI ≫ a false alarm).
  • Device shift. Under a genuine device shift (Schiller CS-family → AT-family within PTB-XL), Tier I exactness and Tier III soundness are distribution-free by construction; only Tier II coverage level is shift-sensitive, and it is restored by weighted conformal + a small-slice recalibration.

5. Results

Synthetic validation (results/synthetic_validation.png) — all three claims hold exactly: Tier I error grows linearly with noise at slope κ; the Bayes-optimal reconstructor's Tier III error equals the Var(u) lower bound while a hallucinator doubles it; the flag's false-flag rate is 0.099 ≤ α=0.1 with power → 1.0; Mondrian-CQR attains 0.90 coverage.

PTB-XL — the certificate localises and explains. Reconstructing from {I, II, V2} on the held-out fold, a scalar RMSE ranks three reconstructors (the generative model is worst) but does not say which feature is wrong or why. The certificate does:

segment method RMSE (mV) h (mV) ρ (oracle)
QRS dipolar 0.196 0.000 +0.00
QRS OLS (learned linear) 0.196 0.030 +0.13
QRS generative 0.228 0.097 +0.00
ST dipolar 0.125 0.000 +0.00
ST OLS 0.112 0.016 +0.28
ST generative 0.149 0.063 −0.00
T dipolar 0.140 0.000 +0.00
T OLS 0.105 0.028 +0.44
T generative 0.163 0.067 −0.00

h is the deployable hallucination energy (no ground truth); ρ is an oracle diagnostic (needs the true leads) used to validate that flagged energy is fabricated. The dipolar baseline never fabricates (h=0) but recovers only Tier I; OLS's non-dipolar energy is correlated with truth (it genuinely recovers Tier II); the generative model's is not. Honest caveat: h alone need not separate blur from fabrication when energies match — the dependable, deployable signal is the configuration-level certificate (κ, tiers) plus the held-out flag.

Fabrication is the objective, not the network — a real diffusion model, measured non-circularly (results/gpu_diffusion_frontier.png). A subtlety makes the naive test circular: on the certified-unrecoverable subspace, correlation-with-truth ρ≈0 for any sampler (even Bayes-optimal), so ρ≈0 there measures the definition, not fabrication. We defeat this with a held-out recoverability oracle — a supervised ridge predictor whose out-of-sample correlation ρ_oracle is a lower bound on recoverability: ρ_oracle>0 proves content is recoverable (a linear map attains it). For S={I,II,V1,V3,V5}→{V2,V4,V6} the QRS non-dipolar content is provably recoverable (ρ_oracle=+0.33). We then train a real conditional 1-D DDPM (classifier-free guidance + RePaint) on PTB-XL and score it with the certificate, comparing the diffusion posterior mean (variance-free) to a single deployed draw to avoid a mean-vs-sample confound. At the honest end (guidance w=1) the posterior mean matches the oracle (Δρ≈0 — the model is competent); as guidance pushes toward realism, the mean develops a growing recoverability deficit — monotone in the seed mean and in 3 of 4 independently trained models (all 4 for w≥2), reaching Δρ = +0.15 ± 0.03 at w=6 (≈4.3σ over seeds). Through the operational regime (w≤4) RMSE stays flat (~0.21 mV, posterior mean) and the model stays faithful on the recoverable dipole subspace (ρ_recoverable≈0.89) even though the deficit is already present, if marginal (+0.08 ± 0.04, ~1.9σ) — the fabrication is invisible to a scalar and localized only by the certificate. Only at extreme guidance (w=6) does the model visibly degrade on every metric (RMSE→0.32), by which point the certificate had flagged it all along. On the limb-6 control the linear reference is lower but nonzero; the diffusion matches or exceeds it (Δρ stays negative) — no false alarm. (A complementary results/neural_perception_distortion.png shows the same phenomenon in a CNN swept over an explicit distortion–perception weight.)

Safety case (honest). Reconstructing precordial leads from limb-6 (κ=6.7×10⁴, effective rank 2 → precordial ST is Tier III) is certified unsafe upfront. Over 799 records the danger is bidirectional and RMSE-invisible (~0.075 mV ST error all methods): the generative model fabricates 263 phantom STEMIs, OLS masks 360 real ones, and even the dipolar reconstructor fabricates 226 (inside the recoverable subspace, where h is blind — its flag correctly never fires). The null-space flag catches only a minority of fabrications (18/263, held-out threshold). The reliable safety signal is the configuration-level κ warning, not the per-record flag.

Device shift. CS→AT device shift drops Tier II coverage 0.90→0.82; a 300-record recalibration restores it to 0.93 at modest width increase (0.15→0.24 mV). (Naive likelihood-ratio weighting over-widens to trivial 1.00 coverage — not a repair.) Only the Tier II level is shift-sensitive; Tier I exactness and Tier III soundness hold.

Cross-dataset (results/cross_dataset.json). The certificate's only data-estimated object — the dipolar subspace M_s, hence the conditioning κ_s(S) — is population-independent. Refit on the geographically distinct Chapman-Shaoxing-Ningbo database (349 Chinese hospital records, identical processing), the per-segment dipolarity matches PTB-XL (QRS 0.88/0.91, ST 0.76/0.72, T 0.76/0.74), the dominant QRS dipole directions align (principal angles ≤21°), and the well-conditioned κ_s(S) agrees (the exhibit's {I,II,V1,V3,V5}: 2.3 vs 2.5). The lead-mixing operator T (Einthoven/Goldberger) is dataset-independent by definition; the fit confirms the estimated M_s is too — except the lowest-variance dipole direction of the less-dipolar ST/T segments, and limb-6, which is effectively rank-deficient in both cohorts (κ≳10⁴, magnitude numerically unstable). (κ is not pure algebra — it depends on the estimated M_s; only the lead operator T is.)

6. Repository layout

src/ecgcert/
  physics/dipolar_subspace.py   # lead algebra, per-segment M_s, kappa_s(S) certificate
  certify/tier_decomposition.py # Tier I/II/III projectors, hallucination energy h
  conformal/mondrian_cqr.py     # Mondrian-CQR, conformal risk control, weighted conformal
  estimators/reconstructors.py  # dipolar / Bayes / OLS / generative reconstructors
  models.py                     # fit per-segment (M_s, mu_s, Sigma_r) from a population
  clinical.py                   # ST-deviation measurement + STEMI flip counting
  data/ptbxl.py                 # PTB-XL loader + NeuroKit2 P/QRS/ST/T delineation
estimators/diffusion.py         # conditional 1-D DDPM (CFG + RePaint), GPU
experiments/
  synthetic_dipole_injection.py # M3: validates all theorems (figures)
  ptbxl_reduced_lead.py         # M4: 3 configs, baselines, hallucination quantification
  ptbxl_stemi_safety.py         # M5: fabricated/masked STEMI + abstention (held-out flag)
  cross_device.py               # M5b: CS->AT device-shift coverage + repair
  neural_baselines.py           # M6: real CNN distortion->perception sweep (CPU)
  gpu_fabrication.py            # M7: oracle gate (Band A/B) + diffusion scoring (GPU)
  gpu_diffusion_clean.py        # M8: de-noised CRAFT exhibit + --ci error bars (GPU)
  gpu_diffusion_figure.py       # M8: recoverability-deficit frontier figure (+CI bars)
  cross_dataset.py              # M9: Chapman-Shaoxing-Ningbo M_s/kappa transfer check
scripts/
  download_data.py              # PTB-XL via HuggingFace mirror (GFW-friendly)
  precheck_dipolarity.py        # risk-2 gate: per-segment dipolarity by diagnosis
tests/                          # 19 theorem-vs-simulation checks
paper/                          # ICASSP spconf LaTeX source

7. Installation and full reproduction

# 1. environment (Python 3.11)
uv venv --python 3.11 .venv
uv pip install --python .venv/Scripts/python.exe -e .

# 2. data (PTB-XL, ~1.8 GB, via HuggingFace mirror — see §8)
.venv/Scripts/python.exe scripts/download_data.py --dataset ptbxl

# 3. the risk-2 gate + all experiments
.venv/Scripts/python.exe scripts/precheck_dipolarity.py
.venv/Scripts/python.exe experiments/synthetic_dipole_injection.py
.venv/Scripts/python.exe experiments/ptbxl_reduced_lead.py
.venv/Scripts/python.exe experiments/ptbxl_stemi_safety.py
.venv/Scripts/python.exe experiments/cross_device.py

# 4. tests (all theorems cross-checked by simulation)
.venv/Scripts/python.exe -m pytest -q

The synthetic experiment and calibration run in seconds on a CPU; the PTB-XL experiments are dominated by NeuroKit2 delineation (a few minutes each).

8. Data access (important under GFW)

PhysioNet's HTTPS endpoint is unreachable from some networks (direct connections are dropped; some proxies reset the TLS handshake to physionet.org specifically). The downloader therefore pulls PTB-XL from the byte-complete HuggingFace mirror longisland3/ptb-xl via hf-mirror.com with curl (resumable). Raw data is not committed to git; run the downloader. If your network reaches PhysioNet directly, use --source physionet.

9. What each test proves

test claim
test_physics::test_lead_algebra_rank8_and_relations the encoded 12-lead algebra is exact (rank 8, Einthoven/Goldberger)
test_physics::test_dipolar_subspace_matches_dower the data-estimated dipolar subspace equals the inverse-Dower column space
test_physics::test_tier1_exact_recovery_noiseless Tier I recovers all 12 leads exactly for a dipole-spanning set
test_physics::test_kappa_geometry_not_leadcount κ / rank distinguish spanning from coplanar/collinear configs
test_physics::test_tier1_noise_amplification_matches_kappa reconstruction error obeys ‖·‖ ≤ κ‖n‖ and attains it
test_certify::* Tier projectors, h = 0 for faithful dipolar, h grows with injection, supported-reconstruction strips fabrication
test_conformal::* marginal + group-conditional coverage, false-flag control, weighted conformal recovers coverage under shift
test_synthetic_theory::* the paper's synthetic figures match their theorems (Tier I κ law, Tier III Var(u) bound, flag, coverage)

10. Relation to prior work

  • Reduced-lead reconstruction (U-Net/GAN/diffusion, e.g. arXiv:2502.00559, arXiv:2401.05388): reports aggregate MSE; qualitatively notes non-dipolar content is hard. We turn that into a per-feature certificate with calibration and a flag.
  • Hallucination in inverse problems (arXiv:2605.13146, arXiv:2510.10947): general theory of unrecoverability and distribution-free assessment. We use it and add the ECG-physical positive certificate κ_s(S) and clinical metering.
  • Vectorcardiography / inverse-Dower (Edenbrandt & Pahlm 1988): the classical whole-beat dipole map, which is our Tier I baseline, not our contribution — ours is per-segment, per-configuration, and calibrated.
  • Conformal prediction (CQR, conformal risk control, weighted conformal): the calibration layer; the novelty is the physics that tells conformal what to calibrate.

11. Honest limitations

  • The dipolar approximation is weakest in some pathologies; we never assume exact rank 3, and the conformal layer makes subspace approximation affect interval width, not validity (decreasing dipolarity correctly widens intervals and raises flags).
  • Dipolarity is feature-and-pathology specific; we do not claim a monotone "disease lowers dipolarity" (it does not — see results/precheck_dipolarity.json).
  • PTB-XL has no per-lead ST-elevation millivolt label; the STEMI safety case uses a measured ST-deviation endpoint (J+60 ms, 0.1 mV), stated as such.
  • The deployable hallucination energy h detects fabrication in the null space; it is blind to error inside the recoverable subspace (a contaminated dipole estimate), which is instead warned by the conditioning κ. The dependable, deployable signal is the configuration-level certificate (κ + tiers) plus the held-out flag; the correlation ρ used in the results table is an oracle diagnostic (needs ground truth) that only validates what h measures.
  • The sampled "generative" baseline is an idealised perceptual endpoint; the honest fabrication evidence is the real trained-CNN perception-distortion sweep. The certificate is reconstructor-agnostic and wraps any method.
  • Theorem 1 is honest about scope: recovery is exact only in the purely-dipolar limit; otherwise the observed non-dipolar residual contaminates the estimate, amplified by the same κ (which is why a large κ is a warning, not just a noise bound).

12. 中文速览

减少导联的 ECG 重建是病态逆问题。现有方法只报一个平均误差,而生成式重建会编造有临床意义的形态(伪造 ST 抬高等)。本项目按 P/QRS/ST/T 逐特征、逐导联给出可恢复性证书:Tier I(偶极分量,可证精确,噪声增益 κ_s(S) 闭式)、Tier II(人群相关非偶极内容,分布无关校准区间)、Tier III(与观测独立的局部内容,任何"重建"都是幻觉→有保证地标记,假标记率 ≤ α)。理论内核是通用逆问题理论没有的 ECG 物理结构:每个波形段≈秩3心脏偶极+非偶极残差。在 PTB-XL 上,RMSE 几乎相同的重建器被证书清晰区分:生成式在"已认证不可恢复子空间"放入大量能量却与真值零相关(自信地幻觉)。所有定理都由测试套件的蒙特卡洛仿真交叉验证(19 个测试)。

13. Citation & license

Preprint in preparation (target IEEE ICASSP). MIT License (see LICENSE). Built with NeuroKit2 and PTB-XL.

About

Certified Reduced-Lead ECG Reconstruction: a per-feature recoverability certificate with distribution-free calibration (IEEE ICASSP target)

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages