APAPUMP

APAPUMP

Autonomous filtration pump controller for APA Devices pool automation · v1.0.0 · Platforms


Key Features

Pump control

  • PCF8574AT I2C relay expander (default) or direct Arduino GPIO — one constructor covers both
  • Non-blocking state machine: IDLE → STARTING → RUNNING → STOPPING
  • Safe boot: all relays start OFF regardless of previous relay or pin state
  • Manual override: FORCE_ON, FORCE_OFF, AUTO — with optional timeout or midnight auto-return
  • Extension relay outputs on PCF P4–P7 for lights or extra equipment

Scheduling and daily tracking

  • Schedule callback drives pump on/off without any external library
  • Daily runtime target with catch-up logic and optional time window
  • Midnight rollover via RTC epoch callback or 24-hour millis() fallback

Follower devices

  • UVC sanitizer — ON before pump, OFF after (configurable pre/post delay)
  • AUX device (heat pump, ozone, etc.) — ON after pump, OFF before pump stops
  • Solar valve — opens when solar drives the pump; instantly closes in manual mode

Solar heating

  • Absorber–pool temperature dead-band hysteresis (configurable start/stop deltas)
  • Pool cooling: runs in reverse when pool temperature exceeds maximum
  • Day/night boundary gate via RTC epoch callback
  • Solar safety (Priority 0): absorber too hot → pump ON + valve OPEN, overrides even FORCE_OFF

Safety alarms

  • Overcurrent — EMA-learned baseline × 1.5 threshold; cold-start gate of 5 samples
  • Dry-run — pressure below EMA baseline × 40% (or absolute minimum before EMA builds)
  • Overpressure — absolute hard limit at maxPressure AND EMA-relative dirty-filter detection
  • Freeze protection — pool temp below 4.5 °C → cyclic run (5 min ON / 10 min rest); suppressed if dry-run detected
  • No-flow stub — flow switch confirmed after settle; hardware-ready for future sensor
  • All alarms are latching — explicit acknowledgeAlarm() required

Engineering

  • 564 B SRAM on Arduino Uno with all features registered — fits comfortably in 2 KB
  • 23 boolean flags packed into 3 bytes; all string literals in flash (F() macro)
  • EEPROM: 12 bytes, magic + version + checksum validation, persists target and clean pressure
  • Zero delay() calls — every path returns within one loop() iteration
  • Designed to integrate with APADOSE and APALCDGUI via callback bridges — no coupling

Installation

Arduino IDE: Sketch → Include Library → Add .ZIP Library → select the APAPUMP folder.

PlatformIO:

lib_deps =
    https://github.com/apadevices/APAPUMP

What It Does

APAPUMP controls a pool filtration pump and up to three follower devices (UVC lamp, AUX device, solar valve) through a PCF8574AT I2C relay expander or direct Arduino output pins. Each call to update() in your loop() advances the state machine, checks every safety guard in priority order, and fires alarm callbacks when something is wrong — all without blocking.

Out of the box, the zero-arg constructor targets the APA Devices HMI board v1.0: PCF8574AT at 0x3C with pump on P0, UVC on P1, AUX on P2, and solar valve on P3. Every optional feature is disabled by default and activated with one method call.


How It Works

State machine

                                ┌──────────────────────────────────┐
                                │           pump.begin()           │
                                ▼                                  │
                             [ IDLE ]                              │
                                │                                  │
                   _shouldPumpRun() = true                         │
                   min OFF time OK (60 s)                          │
                                │                                  │
                          [ STARTING ]                             │
                                │                                  │
                   UVC pre-delay (default 5 s)                     │
                                │                                  │
                          [ RUNNING ] ◄── safety alarms checked:   │
                                │         current · pressure ·     │
                                │         flow · freeze            │
                   _shouldPumpRun() = false                        │
                   min run time OK (300 s)                         │
                                │                                  │
                         [ STOPPING ]                              │
                                │                                  │
          AUX lead ──► pump OFF ──► UVC post-delay ────────────────┘

Guards that bypass min-run time: FORCE_ON and FORCE_OFF — manual mode suspends timing guards.

Follower timing

Time →    0         5s         15s       [pump runs…]   Ts-30s    Ts      Ts+30s
          │          │          │                │        │         │        │
UVC:      ├──ON──────┼──────────┼────────────────┼────────┼─────────┼──OFF───┤
Pump:               ON──────────────────────────────────OFF
AUX:                           ON───────────────OFF
          ◄─ pre ──►◄──────────────── RUNNING ──────────►◄─ lead ─►◄─ post─►

Ts = moment the stop sequence begins. pre = enableUVC(preDelayS, …). lead = enableAux(…, stopLeadS). post = enableUVC(…, postDelayS).

Priority engine

Every update() tick calls the priority engine. The first rule that matches wins:

Priority Condition Result
P0 Solar absorber > safety temp (default 50 °C) Pump ON + valve OPEN — overrides FORCE_OFF
P1 FORCE_OFF manual mode Pump OFF
P2 FORCE_ON manual mode Pump ON
P3 External request callback returns true Pump ON
P4 Freeze: pool temp < threshold AND water present Pump ON
P5a Solar: absorber > pool + startDelta Pump ON (hysteresis)
P5b Catch-up: daily runtime < daily target (window OK) Pump ON
P5c Schedule callback returns true Pump ON
None of the above Pump OFF

PCF relay layout (APA HMI board v1.0 defaults)

PCF8574AT at I2C address 0x3C
│
├─ P0 ── Pump relay              (always required)
├─ P1 ── UVC relay               (optional — enableUVC())
├─ P2 ── AUX relay               (optional — enableAux())
└─ P3 ── Solar valve relay       (optional — enableSolar(…, useValve=true))
│
├─ P4 ── Extension relay         (optional — setExtraOutput(4, on/off))
├─ P5 ── Extension relay         (optional — setExtraOutput(5, on/off))
├─ P6 ── Extension relay         (optional — setExtraOutput(6, on/off))
└─ P7 ── Extension relay         (optional — setExtraOutput(7, on/off))

PCF HIGH = relay ON, LOW = relay OFF. begin() writes 0x00 immediately — all relays start OFF.


Quick Start

Minimal — APA HMI board defaults (zero wiring, zero config)

#include <Wire.h>
#include <APAPUMP.h>

ApaPump pump;              // PCF at 0x3C — pump=P0, uvc=P1, aux=P2, valve=P3

void setup() {
    Wire.begin();          // required for PCF mode — call before pump.begin()
    pump.begin();          // all relays OFF, EEPROM loaded
}

void loop() {
    pump.update();         // non-blocking — call every loop()
}

Alternative: direct GPIO

// Active-high relay (most modules)
ApaPump pump(RELAY_DIRECT, 7);               // pump on pin 7

// Active-low relay (some modules)
ApaPump pump(RELAY_DIRECT, 7);
pump.setActiveLow();             // call BEFORE pump.begin()

// Multiple relays, direct GPIO
ApaPump pump(RELAY_DIRECT, 7, 8, 9, 10);    // pump=7, uvc=8, aux=9, valve=10

Scheduled pump with alarm feedback

#include <Wire.h>
#include <APAPUMP.h>

ApaPump pump;

bool scheduleActive() {
    // return true when your RTC time falls inside a timer slot
    return false;  // replace with real logic
}

void onAlarm(PumpAlarm alarm) {
    if (alarm == PUMP_ALARM_NONE) return;   // alarm was cleared
    Serial.print(F("Pump alarm: "));
    switch (alarm) {
        case PUMP_ALARM_OVERCURRENT:   Serial.println(F("overcurrent"));   break;
        case PUMP_ALARM_LOW_PRESSURE:  Serial.println(F("dry run"));       break;
        case PUMP_ALARM_HIGH_PRESSURE: Serial.println(F("high pressure")); break;
        case PUMP_ALARM_NO_FLOW:       Serial.println(F("no flow"));       break;
        default: break;
    }
    // pump continues running — call pump.acknowledgeAlarm() when investigated
}

void setup() {
    Wire.begin();
    pump.begin(scheduleActive);             // schedule drives on/off
    pump.enableUVC(5, 30);                  // UVC: 5 s pre, 30 s post
    pump.enableAux(10, 30);                 // AUX: 10 s delay, 30 s lead
    pump.setPumpAlarmCallback(onAlarm);
}

void loop() { pump.update(); }

Manual Override

Force the pump on or off at any time. All timing guards and schedules are suspended:

pump.setManualMode(FORCE_ON);   // force pump ON  (e.g. vacuuming, winterising)
pump.setManualMode(FORCE_OFF);  // force pump OFF (e.g. plumbing, service)
pump.setManualMode(AUTO);       // return to automatic control

The solar valve closes immediately when entering FORCE_ON — operator gets full system pressure.

Auto-return options — pick one or both:

// Timeout: returns to AUTO after 60 minutes
ApaPump pump(RELAY_PCF, 0x3C, 0, 1, 2, 3, 60);   // 6th constructor parameter
pump.setManualTimeout(60);                           // or set at any time

// Midnight reset (requires setMidnightCallback())
pump.setManualAutoReset(true);

Note: Solar safety (P0) still applies even in FORCE_OFF. If the absorber reaches the safety temperature, the pump runs to prevent heat damage regardless of manual mode.


Followers: UVC, AUX, Solar Valve

Each follower is independent and optional. Wire the relay to the corresponding PCF bit (or GPIO pin), then call the enable method:

// UVC lamp: ON 5 s before pump, OFF 30 s after pump stops
pump.enableUVC(5, 30);

// AUX device (heat pump, ozone): ON 10 s after pump starts, OFF 30 s before pump stops
pump.enableAux(10, 30);

// Solar valve: open when solar logic drives the pump
// useValve=true enables the valve relay on P3 (or direct pin d)
pump.enableSolar(absorberTempCb, poolTempCb, /*useValve=*/true, ...);

UVC pre-delay — when a pre-delay is configured, the pump enters STARTING state while UVC warms up. If the reason to start disappears during STARTING (e.g. schedule ends), the sequence is cancelled cleanly — UVC turns off and the pump never fires.


Solar Heating

Solar logic becomes the sole on/off driver when enabled — the schedule callback is only used for the daily runtime target.

pump.enableSolar(
    []() { return adc.getSolarTemp(); },   // absorber temperature callback
    []() { return adc.getPoolTemp(); },    // pool temperature callback (optional)
    true,                                  // useValve — open valve when solar running
    8.0f,                                  // startDelta: start when absorber > pool + 8°C
    3.0f,                                  // stopDelta:  stop  when absorber < pool + 3°C
    32.0f,                                 // maxPoolTemp: pool cooling if pool > 32°C
    2.0f,                                  // coolDelta: cool when absorber < pool - 2°C
    50.0f                                  // safetyTemp: force pump ON if absorber > 50°C
);

// Optional: restrict solar heating to daytime hours
pump.setSolarDayNight(
    []() { return rtc.getEpoch(); },       // Unix epoch callback
    7,                                     // daytime starts at 07:00
    20                                     // daytime ends at 20:00
);

Solar hysteresis

Absorber temp
     │
     │                     START threshold = pool + startDelta
─────┼──────────────────────────────────────────────────────
     │   ← pump ON                               pump ON →
     │
─────┼──────────────────────────────────────────────────────
     │                     STOP threshold = pool + stopDelta
     │

The gap between start and stop thresholds prevents rapid on/off cycling when temperature hovers near the boundary. Increase startDelta − stopDelta for wider hysteresis.


Daily Runtime Target and Catch-Up

// Option A: fixed target (user sets it once)
pump.setDailyTarget(360);                   // run 6 hours per day

// Option B: use the APALCDGUI timer sum as the target
pump.begin(scheduleActive, nullptr,
           []() { return gui.getTimerTotalMinutes(); });

// Query progress
uint16_t ran = pump.getDailyRuntimeMinutes();
bool     met = pump.isDailyTargetMet();

When solar is enabled and the daily target is not met, catch-up runs until the target is reached:

// Optional: limit catch-up to daytime hours (requires setMidnightCallback)
pump.setCatchupWindow(8, 20);   // catch-up only between 08:00 and 20:00

Safety Alarms

All alarms are latching — the pump does not stop automatically (your alarmCb decides the action). Call acknowledgeAlarm() after investigation to clear.

Alarm Triggers when Requires
PUMP_ALARM_OVERCURRENT current > learned baseline × 1.5 setCurrentCallback()
PUMP_ALARM_LOW_PRESSURE pressure below 40% of EMA baseline (dry-run) enablePressure()
PUMP_ALARM_HIGH_PRESSURE pressure > maxPressure OR > EMA × (1+peakPct%) enablePressure() + setPressurePeakAlarm()
PUMP_ALARM_NO_FLOW flow switch reports no flow after 30 s settle setFlowCallback()

Alarm callback pattern:

pump.setPumpAlarmCallback([](PumpAlarm alarm) {
    if (alarm == PUMP_ALARM_NONE) {
        // alarm was acknowledged — update LCD, clear indicator
        gui.cancelActiveAlert();
        return;
    }
    // alarm fired — notify operator
    gui.postActiveAlert(F("Pump alarm!"), F("Check equipment"),
                        ALERT_CRITICAL, []() { pump.acknowledgeAlarm(); });
});

Wiring a buzzer or alarm output

The alarm callback is the right place to drive any physical indicator — buzzer, LED, relay. No extra library method needed:

pump.setPumpAlarmCallback([](PumpAlarm alarm) {
    bool active = (alarm != PUMP_ALARM_NONE);
    digitalWrite(5, active ? HIGH : LOW);   // buzzer on pin 5
    // LEDs on a PCF expander — drive via APASENSE:
    // adc.setLed(4, active);
});

Tip: if you use APALCDGUI, a future release will add gui.setBuzzerPin(pin) to drive the buzzer automatically from the alert level (INFO / WARNING / CRITICAL) without any sketch code.

Dry-run protection

When enablePressure() is registered, APAPUMP builds a dual pressure baseline (EMA): one for normal running, one for when the solar valve is open (higher pressure expected due to absorber resistance). After 5 pump runs, if pressure stays near zero after 30 s, PUMP_ALARM_LOW_PRESSURE fires.

Before the EMA baseline builds (first 5 runs), an absolute minimum of 0.1 bar is used.

Freeze protection

pump.enableFreezeProtection(
    []() { return adc.getPoolTemp(); },   // pool/pipe temperature
    4.5f                                  // threshold in °C (default)
);

When pool temperature drops below the threshold, the pump cycles to prevent pipes from freezing: runs for APAPUMP_FREEZE_ON_SEC (default 5 min), rests for APAPUMP_FREEZE_OFF_SEC (default 10 min), and repeats until temperature rises. Both durations are overridable via build_flags. Dry-run interlock: if the pressure sensor is enabled, calibrated, and indicates no water in the pipes (pressure near zero), freeze protection is suppressed — forcing the pump without water would burn the motor.


Integrating with APADOSE and APALCDGUI

APAPUMP, APADOSE, and APALCDGUI are independent libraries — your sketch is the bridge. No library knows about the others.

Bridge: APALCDGUI timer → APAPUMP schedule

// In begin(): pass a lambda that reads the timer state from the GUI
pump.begin(
    []() {
        // return true when current time falls inside any timer slot
        uint16_t nowMin = rtcHour * 60 + rtcMinute;
        for (uint8_t i = 0; i < APA_LCD_MAX_TIMERS; i++) {
            if (gui.isTimerEnabled(i) &&
                nowMin >= gui.getTimerStart(i) &&
                nowMin <  gui.getTimerEnd(i)) return true;
        }
        return false;
    },
    nullptr,
    []() { return gui.getTimerTotalMinutes(); }  // daily target from timer sum
);

Bridge: APADOSE post-shock → APAPUMP

// After a shock dose, run the pump for 4 hours to circulate the chlorine.
// Uses the externalRequestCb — no new API needed.

static uint32_t postShockUntil = 0;

pump.begin(scheduleCb,
    []() {
        // Shock is running: extend the post-shock window
        if (dose1.isShockActive()) {
            postShockUntil = millis() + 4UL * 3600UL * 1000UL;
            return true;
        }
        // Pump on until post-shock window expires
        return (millis() < postShockUntil);
    }
);

Bridge: pump manual mode → APALCDGUI status indicator

// Show [M] in the LCD corner whenever the pump is in manual mode
pump.setStatusCallback([](const __FlashStringHelper* msg) {
    if (pump.getManualMode() != AUTO) gui.setStatusIndicator('M');
    else                              gui.clearStatusIndicator();
    // Also forward the status text to a scrolling message area
    Serial.println(msg);
});

Bridge: APASENSE → APAPUMP (pressure and current)

// Order: adc.begin() BEFORE pump.begin() — pressure auto-zeros on first pump stop.
// pressureCb returns -1.0f while APASENSE is uncalibrated — APAPUMP skips
// all pressure logic until a valid reading arrives.

adc.begin();    // zero-cal requires pump off — call first

pump.begin();
pump.enablePressure(
    []() { return adc.getPressure(); },    // -1.0f until calibrated
    4.0f                                   // absolute max pressure (bar)
);
pump.setCurrentCallback([]() { return adc.getCurrent(); });

// Bridge: tell APASENSE when pump state changes so it can re-zero on pump stop
pump.setPumpStateCallback([](bool on) { adc.onPumpState(on); });

Examples

Sketch Level Description
examples/01_minimal/ Basic PCF or GPIO, manual override via Serial, all three constructor options
examples/02_scheduler/ Intermediate APALCDGUI timer schedule, UVC + AUX followers, alarm → active alert bridge
examples/03_solar_freeze/ Advanced Solar heater + solar valve, freeze protection, pressure safety, APADOSE post-shock bridge

Platform Verification

Compiled with the 01_minimal example. Zero errors, zero library warnings on all platforms.

Platform Board RAM used RAM total Flash used Flash total
Arduino Mega 2560 ATmega2560 564 B 8 192 B (6.9%) 11 860 B 253 952 B (4.7%)
Arduino Uno ATmega328P 564 B 2 048 B (27.5%) 11 094 B 32 256 B (34.4%)
ESP32 DevKit ESP32 22 024 B 327 680 B (6.7%) 290 493 B 1 310 720 B (22.2%)
ESP8266 D1 Mini ESP8266 28 852 B 81 920 B (35.2%) 274 147 B 1 044 464 B (26.2%)
STM32 Bluepill STM32F103C8 2 628 B 20 480 B (12.8%) 25 984 B 65 536 B (39.6%)

The Uno row uses 27.5% RAM — that is the library with all Phase 2 features registered in the example. A minimal sketch (no solar, no pressure, no freeze) sits below 20%. ESP32 and ESP8266 totals include the full Arduino framework regardless of use.


EEPROM Layout

APAPUMP reserves 12 bytes starting at APAPUMP_EEPROM_ADDR (default 520).

Field map

Address Bytes Field Saved when
520 2 Magic 0xA55A — validity marker
522 1 Config version — mismatch resets all fields to defaults
523 2 Daily target (minutes) setDailyTarget()
525 2 Yesterday's runtime (minutes) Midnight rollover (once per day)
527 2 Minimum run time (seconds) setMinRunTime()
529 2 Clean pressure × 100 (bar; 0 = not learned) learnCleanPressure() / setCleanPressure()
531 1 Checksum (byte sum of bytes 520–530) — corruption guard

Write protection and EEPROM lifespan

_saveEEPROM() writes the full 12-byte struct, but a physical write only occurs when a byte has actually changed:

  • AVR (Uno/Mega): EEPROM.put() calls EEPROM.update() per byte — reads first, writes only if value differs.
  • ESP32/ESP8266: EEPROM.put() updates a RAM buffer; EEPROM.commit() compares the buffer to flash before writing — no flash write if content unchanged.
  • STM32: EEPROM emulation with compare-before-write.

Practical write frequency (worst case on a running system):

Event Max frequency Cycles used at 100 k limit
Midnight rollover 1 per day 100 k days ≈ 273 years
learnCleanPressure() Operator action Negligible
setMinRunTime() from setup() 0 physical writes if value unchanged None
First boot / corruption recovery Once 1 cycle

Corruption recovery: the checksum is verified on every begin(). If power fails mid-write and data is corrupted, the mismatch is detected on the next boot, factory defaults are loaded, and a clean struct is written.

Override base address

// Define before #include if the default conflicts with another library in your project:
#define APAPUMP_EEPROM_ADDR  532
#include <APAPUMP.h>

APA EEPROM address map

All ranges across the APA library suite — free blocks shown explicitly:

Range Bytes Status Owner
0–127 128 free
128–177 50 used APAPHX2_ADS1115 (sensor calibration)
178–188 11 free
189–191 3 used APADOSE global (pool volume, dead-band)
192–279 88 used APADOSE per-pump config (22 bytes × up to 4 instances)
280–499 220 free
500–501 2 used APALCDGUI brightness
502–508 7 used APALCDGUI timer slots (default 3 slots)
509–519 11 free — gap before APAPUMP ¹
520–531 12 used APAPUMP
532– free

¹ When APA_LCD_MAX_TIMERS=6 the timer block extends to 514, leaving a 5-byte gap (515–519) before APAPUMP. This gap is intentional — do not place anything in 515–519 to keep the gap safe regardless of timer configuration.


License

Dual license — see LICENSE file for full terms.

Use License
Personal, private, educational, hobby Free — no charge, no paperwork
Commercial (products, services, OEM) Separate written license required

Commercial use includes selling or distributing hardware with this software, providing paid pool automation services, or integrating it into any revenue-generating product or system.