Alfen Modbus for Home Assistant

HACS Default GitHub Release License

Home Assistant integration for Alfen Eve NG9xx and AHP series EV chargers via Modbus TCP.

Demo

Features

  • 🔌 Real-time monitoring - Voltage, current, power, energy for all phases
  • 🚗 Car status detection - Connected, charging, disconnected states
  • Load balancing control - Set maximum charging current dynamically
  • 🛡️ Max current protection - Prevents setting current above station limit
  • 📊 Session tracking - Energy consumed and duration per charging session
  • 🔄 Auto-renew max current - Prevents timeout to safe current mode
  • 🏢 Multi-socket support - Works with dual socket chargers
  • 🌐 SCN support - Smart Charging Network: per-phase consumption, actual/max/safe current and enable state, with a control to set the max current per phase
  • 🗣️ Localized UI - Entity names and states are translated into English, Dutch, German, French, Finnish, Norwegian, Swedish and Danish, following your Home Assistant language setting
  • 🩺 Diagnostics - Download a redacted diagnostics report from Settings → Devices & Services for bug reports
  • 🚑 Repair notifications - Flags known issues (e.g. outdated NG9xx firmware) directly in Settings → Repairs

Requirements

  • Home Assistant 2025.10.0 or newer
  • A supported Alfen charger (see Supported Platforms) with:
    • The minimum firmware version for your platform
    • Active Load Balancing license enabled
  • Modbus TCP enabled on the charger

Supported Platforms

Platform Minimum firmware Notes
Eve NG9xx 4.2.0 (adds Modbus TCP support); 6.4.0+ recommended Fixes a power budget reset bug — see Known Issues
AHP (e.g. AHP02-60227) 2.6.0 (release notes) — currently the latest AHP firmware Requires integration v0.2.1+; earlier versions fail every poll cycle because AHP rejects Modbus reads that don't align to register value boundaries (#40)

Installation

HACS (Recommended)

  1. Open HACS in Home Assistant
  2. Search for "Alfen Modbus"
  3. Click Install
  4. Restart Home Assistant

Manual

  1. Copy custom_components/alfen_modbus to your config/custom_components/ folder
  2. Restart Home Assistant

Configuration

  1. Go to SettingsDevices & Services
  2. Click Add Integration
  3. Search for Alfen Modbus
  4. Enter your charger's IP address and port (default: 502)

Localization

Entity names and on/off states follow the language set in your Home Assistant profile. Currently translated: 🇬🇧 English, 🇳🇱 Dutch, 🇩🇪 German, 🇫🇷 French, 🇫🇮 Finnish, 🇳🇴 Norwegian, 🇸🇪 Swedish and 🇩🇰 Danish. Any other language falls back to English.

Per-socket entities (voltages, currents, power, energy, ...) only show a socket number in the name (e.g. "Socket 2 voltage L1-N") when Read Socket 2 is enabled; single-socket setups get a plain name instead.

Missing your language or spotted an incorrect translation? Pull requests adding or fixing a custom_components/alfen_modbus/translations/<lang>.json file are very welcome.

Enabling Modbus on Alfen Charger

  1. Acquire the Active Load Balancing license from Alfen
  2. Enable Active Load Balancing via the Alfen Service Installer app
  3. Set Data Source to "Energy Management System" for slave mode

See the Alfen Smart Charging Manual for details.

Sensors

Category Sensors
Device Name, Manufacturer, Serial, Firmware, Platform
Station Max Current, Temperature, Backoffice Connection
Socket Voltages (L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1)
Currents (L1, L2, L3, N, Sum)
Power (Real, Apparent, Reactive per phase + Sum)
Energy (Delivered, Consumed per phase + Sum)
Mode 3 State, Availability, Charging Phases
Derived Car Connected, Car Charging, Charger Enabled, Session Wh, Session Duration
SCN (if enabled) Total Consumption, Actual Max Current and Safe Current per phase, Max Current Enabled

Controls

Control Description
Max Current Set the maximum charging current (load balancing)
Phase Mode Select 1-phase ("1") or 3-phase ("3") charging
Charger Enabled Switch that stops (0 A) or resumes (allowed max current) charging via the max-current setpoint
SCN Max Current per phase (if enabled) Set the maximum current for the Smart Charging Network as a whole, per phase

EVCC Integration

EVCC's generic Home Assistant charger lets you map its fields directly to entities from this integration. See docs/evcc.md for a step-by-step walkthrough of EVCC's configuration wizard.

Field mapping

EVCC field Entity Notes
Charging status sensor sensor.alfen_mode_3_state Reports the raw IEC 61851 Mode 3 State (A, B1, B2, C1, C2, D1, D2, E, F). Add the state overrides below so EVCC maps it to its A/B/C.
States for status A E,F Error / EVSE-disabled states, grouped with "ready" the same way this integration's Car Connected sensor does.
States for status B B1,B2,C1,D1 Connected but not drawing current.
States for status C C2,D2 Actively charging (PWM applied).
Enabled status sensor binary_sensor.alfen_charger_enabled On when the max-current setpoint is above 0 A.
Enable switch switch.alfen_charger_enabled Off writes 0 A to the max-current register; on restores the station's currently allowed max current.
Maximum current entity number.alfen_max_current_limit_s1 Must be this writable number entity, not the read-only sensor.alfen_actual_max_current.
Power entity sensor.alfen_real_power_sum
Energy entity sensor.alfen_real_energy_delivered_sum Reported in Wh; add a template sensor to convert to kWh if EVCC doesn't scale it for you.
L1 / L2 / L3 current entity sensor.alfen_current_l1 / _l2 / _l3
L1 / L2 / L3 voltage entity sensor.alfen_voltage_l1_n / _l2_n / _l3_n
Phase switching entity select.alfen_usable_phases Options are the literal values "1" and "3".

With Read Socket 2 enabled, socket 2's entity IDs get a _socket_2 suffix (e.g. sensor.alfen_current_l1_socket_2, switch.alfen_charger_enabled_socket_2).

Note: Alfen has no dedicated enable/disable coil — the charger-enabled switch and sensor are derived from the max-current setpoint (register 1210). Turning charging off/on this way is equivalent to setting number.alfen_max_current_limit_s1 to 0 A or back to its allowed maximum; don't drive both the switch and the number entity from automations at the same time to avoid fighting setpoints.

Known Issues

  • Power budget may reset to 0A when no car is connected (fixed in NG9xx firmware 6.4.0-4210). The integration raises a repair notification in Settings → Repairs if it detects an NG9xx charger on older firmware.
  • Reallin power meter (post-2021): Chargers with a Reallin power meter produced after 2021 only export a subset of measurement values. Per-phase energy, apparent energy, and reactive energy sensors will show as "unavailable" (NaN). This is a hardware limitation, not a bug.
  • AHP platform, integration < v0.2.1: all entities stay unavailable because a single oversized Modbus read fails on every poll cycle. Update to v0.2.1 or newer (#40).
  • Breaking change: the Phase Mode select's options changed from "1 Phase"/"3 Phases" to the literal values "1"/"3" (needed for EVCC compatibility). Update any automation, script, or dashboard that matches on the old option text.