1 change: 1 addition & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0

## [Unreleased]

- Add SHDLC commands: User Data (0x21), Device Selftest (0x22), Sensor Voltage (0x23), Measure Sensor Voltage (0x26)
- Add interface for totalizer
- Ensure linux file endings across the package
- Fix several typos
Expand Down
25 changes: 25 additions & 0 deletions sensirion_uart_scc1/drivers/scc1_ld20.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,25 @@
# -*- coding: utf-8 -*-

from sensirion_uart_scc1.drivers.slf_common import SlfMode, SLF_PRODUCT_LIQUI_MAP, SlfProduct
from sensirion_uart_scc1.scc1_shdlc_device import Scc1ShdlcDevice
from sensirion_uart_scc1.drivers.scc1_sf06 import Scc1Sf06


class Scc1Ld20(Scc1Sf06):
"""
Scc1 LD20 Sensor Driver

The Scc1 provides features to support the LD20 liquid flow sensors. This driver accesses the sensor through the
API specified by scc1.
"""
SENSOR_TYPE = 3 #: Sensor type for LD20 (same as SF06/SLF3x)

def __init__(self, device: Scc1ShdlcDevice, liquid_mode: SlfMode = SlfMode.LIQUI_1) -> None:
"""
Initialize object instance.

:param device: The Scc1 device that provides the access to the sensor.
:param liquid_mode: The liquid that is measured.
"""
super().__init__(device, liquid_mode)
self._liquid_config = SLF_PRODUCT_LIQUI_MAP[SlfProduct.LD20]
257 changes: 257 additions & 0 deletions sensirion_uart_scc1/drivers/scc1_sf06.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,257 @@
# -*- coding: utf-8 -*-

import struct
import time
from typing import List, Tuple, Optional, Any

from sensirion_uart_scc1.drivers.slf_common import SlfMeasurementCommand, SlfMode, SLF_PRODUCT_LIQUI_MAP, SlfProduct
from sensirion_uart_scc1.scc1_exceptions import Scc1InvalidDataReceived
from sensirion_uart_scc1.scc1_shdlc_device import Scc1ShdlcDevice


class Scc1Sf06:
"""
Driver for the SF06 sensor family connected via SCC1 cable.
SF06 sensors are sensor type 3.
"""
SENSOR_TYPE = 3
START_MEASUREMENT_DELAY_S = 0.015

def __init__(self, device: Scc1ShdlcDevice, liquid_mode: SlfMode = SlfMode.LIQUI_1) -> None:
"""
Initialize object instance.

:param device: The Scc1 device that provides the access to the sensor.
:param liquid_mode: The liquid that is measured.
"""
self._scc1 = device
self._liquid_config = SLF_PRODUCT_LIQUI_MAP[SlfProduct.SF06]
self._serial_number, self._product_id = self._get_serial_number_and_product_id()
self._is_measuring = False
self._sampling_interval_ms = 100 # Default 10Hz
self._liquid_mode = liquid_mode
self._measurement_command = SlfMeasurementCommand.from_mode(self._liquid_mode)

@property
def serial_number(self) -> Optional[int]:
"""
Get the serial number

:return: The serial number as integer
"""
return self._serial_number

@property
def product_id(self) -> Optional[int]:
"""
Get the product id

:return: The product identifier as integer
"""
return self._product_id

@property
def liquid_mode(self) -> SlfMode:
"""
Liquid measurement mode
"""
return self._liquid_mode

@liquid_mode.setter
def liquid_mode(self, mode: SlfMode) -> None:
"""
Set liquid measurement mode.

:param mode: One of the liquid measurement modes
"""
from sensirion_uart_scc1.scc1_exceptions import Scc1NotSupportedException
if not isinstance(mode, SlfMode):
raise Scc1NotSupportedException(f"Invalid liquid mode: {mode}")

if self._is_measuring:
raise Scc1NotSupportedException("Set liquid mode not allowed while measurement is running")

self._liquid_mode = mode
self._measurement_command = SlfMeasurementCommand.from_mode(self._liquid_mode)

@property
def liquid_mode_name(self) -> str:
"""
Get the name of the liquid.

:return: Name of current liquid measurement mode
"""
return self.get_liquid_mode_name(self._liquid_mode)

def get_liquid_mode_name(self, mode: SlfMode) -> str:
"""
Get the name of the liquid

:param mode: A liquid mode

:return: The name of a specific liquid measurement mode
"""
return self._liquid_config.liqui_mode_name(mode)

@property
def sampling_interval_ms(self) -> int:
"""
Sampling interval for synchronous measurement

:return: Current internal sampling interval
"""
return self._sampling_interval_ms

@sampling_interval_ms.setter
def sampling_interval_ms(self, interval_ms: int):
"""
Set sampling interval for continuous measurement
This will not be applied while the measurement is running

:param interval_ms: The requested measurement interval in milliseconds
"""
self._sampling_interval_ms = interval_ms

def get_serial_number(self) -> Optional[int]:
"""
Get the serial number of the device.

:return: The sensor serial number
"""
return self._serial_number

def get_flow_unit_and_scale(self, command: Optional[int] = None) -> Optional[Tuple[int, int]]:
"""
Get the scale factor, unit, and sensor sanity check result of the sensor for the given argument.
(available on SF06 sensor products)

:param command: The 16-bit command to read flow unit and scale factor for. If no value is supplied,
the actual measurement command is used
:return: A tuple with (scale_factor, flow_unit), None if the command is not supported
"""
if command is None:
command = self._measurement_command
args = list(struct.pack('>h', command))
data = self._scc1.transceive(0x53, args, 0.01)
if len(data) != 6:
return None
scale, unit, _ = struct.unpack('>HHH', data)
return scale, unit

def get_last_measurement(self) -> Optional[Tuple[int, int, int]]:
"""
Read current measurement and starts internal continuous measurement with the configured interval, if not
already started.

:return: A tuple with flow, temperature, and flag
"""
data = self._scc1.transceive(0x35, [self.SENSOR_TYPE], 0.01)
if not data:
# Measurement is not ready
return None
return struct.unpack('>hhH', data)

def start_continuous_measurement(self, interval_ms=0) -> None:
"""
Start a continuous measurement with a given interval.

:param interval_ms: Measurement interval in milliseconds.
"""
if self._is_measuring:
return
data = bytearray()
data.extend(bytearray(struct.pack('>H', int(interval_ms))))
data.extend(bytearray(struct.pack('>H', int(self._measurement_command))))
self._scc1.transceive(0x33, data, 0.01)
time.sleep(self.START_MEASUREMENT_DELAY_S)
self._is_measuring = True

def stop_continuous_measurement(self) -> None:
"""Stop continuous measurement"""
if not self._is_measuring:
return
self._scc1.transceive(0x34, [], 0.01)
self._is_measuring = False

def read_extended_buffer(self) -> Tuple[int, int, List[Tuple[Any, ...]]]:
"""
Read out measurement buffer for SF06.
SF06 might return multiple signals.

:return: A tuple with (bytes_remaining, bytes_lost, data)
"""
data = self._scc1.transceive(0x36, [self.SENSOR_TYPE], 0.01)
if not data:
return 0, 0, []
bytes_lost = int(struct.unpack('>I', data[:4])[0])
bytes_remaining = int(struct.unpack('>H', data[4:6])[0])
num_signals = struct.unpack('>H', data[6:8])[0]
# For SF06, signals are typically i16
num_packets = int(len(data[8:]) / 2 / num_signals)
buffer = list(struct.unpack(">" + "h" * (num_packets * num_signals), data[8:]))

if len(buffer) % num_signals != 0:
raise Scc1InvalidDataReceived("Received unexpected amount of data")

num_samples = len(buffer) // num_signals
out = [tuple(buffer[i * num_signals:(i + 1) * num_signals])
for i in range(num_samples)]
return bytes_remaining, bytes_lost, out

def get_totalizator_status(self) -> Optional[bool]:
"""
Get the Status (enabled / disabled) of the Totalizator.
:return: True if the totalizator is enabled, False if disabled
"""
return self._scc1.get_totalizator_status()

def set_totalizator_status(self, enabled: bool) -> None:
"""
Enable or disable the Totalizator. The value of the Totalizator is not changed with this command.
:param enabled: True to enable the totalizator, false to disable it
"""
self._scc1.set_totalizator_status(enabled)

def get_totalizator_value(self) -> Optional[int]:
"""
Get the value of the Totalizator for SF06.
For sensor type 3 only: Only the flow values (signal 1) are totalized, and
the values are interpreted as i16 signed integers.
:return: Totalizator value
"""
return self._scc1.get_totalizator_value()

def reset_totalizator(self) -> None:
"""
Set the Totalizator value to zero, the Totalizator Status (enabled/disabled) is
not changed. The Totalizator can be reset anytime.
"""
self._scc1.reset_totalizator()

def get_sensor_status(self) -> Optional[int]:
"""
Get the status of the sensor and the continuous measurement.

:return: Sensor status as integer, None if not available.
"""
return self._scc1.get_sensor_status()

def get_continuous_measurement_status(self) -> Optional[int]:
"""
Get the interval or status of the continuous Measurement.

:return: Measurement interval in ms if started, None if not started.
"""
return self._scc1.get_continuous_measurement_status()

def _get_serial_number_and_product_id(self) -> Tuple[Optional[int], Optional[int]]:
"""
:return: The sensor serial number and product id as tuple
"""
data = self._scc1.transceive(0x50, [], 0.01)
if not data:
return None, None
data = data.rstrip(b'\x00').decode('utf-8')
product_id = int(data[:8], 16)
serial_number = int(data[8:], 16)
return serial_number, product_id
Loading
Loading