MQTT
config/protocol/publish 'strict separate topics' is not needed to activate. You can activate in the mqtt iobroker adapter 'different topic names for read and write'. IOBroker added a '/set' to the write topic. VDMot accept this automatically.

It is mandotary to activate config/protocol/publish 'strict separate topics'. Otherwise the system will fail. (Loop malfunction)

- Station name : VdMotTest
- common topics : (Station name).common
- (Station name).common.heatControl
- (Station name).common.message
- (Station name).common.parkPosition
- (Station name).common.state
- (Station name).common.uptime
- (Station name).valves
- (Station name).valves.(room)
- (Station name).valves.(room).control
- (Station name).valves.(room).control.mode
- (Station name).valves.(room).control.link
- (Station name).valves.(room).window
- (Station name).valves.(room).window.state
- (Station name).valves.(room).window.target
- (Station name).valves.(room).calibration
- (Station name).valves.(room).date
- (Station name).valves.(room).repetitions
- (Station name).valves.(room).diag
- (Station name).valves.(room).openCount
- (Station name).valves.(room).closeCount
- (Station name).valves.(room).deadZoneCount
- (Station name).valves.(room).moves
- (Station name).valves.(room).state
- (Station name).valves.(room).tTarget
- (Station name).valves.(room).tValue
- (Station name).valves.(room).target
- (Station name).valves.(room).control
- (Station name).valves.(room)
Read means the controller publishes the topic
Write means the server sends the topic to the controller
| Topic | Read/Write | Values |
|---|---|---|
| Station name | R (1) | Name of the station defined in configuration |
| (Station name).common.heatControl | R/W (1/2) | 0 or "manual" = manual 1 or "heat" = on/heating 2 or "cool" = on/cooling 3 or "off" = off/parkposition |
| (Station name).common.message | R (1) | Messages : "UNKNOWN": Reset reason can not be determined "POWERON": Reset due to power-on event "EXT": Reset by external pin (not applicable for ESP32) "SW": Software reset via esp_restart "PANIC": Software reset due to exception/panic "INT_WDT": Reset (software or hardware) due to interrupt watchdog "TASK_WDT": Reset due to task watchdog "WDT": Reset due to other watchdogs "DEEPSLEEP": Reset after exiting deep sleep mode "BROWNOUT": Brownout reset (software or hardware) "SDIO" : Reset over SDIO |
| (Station name).common.parkPosition | R/W (1/2) | park position (%) if heatControl is off |
| (Station name).common.state | R (1) | 0 = System OK 1 = System Info 2 = System Error |
| (Station name).common.uptime | R (1) | up time if activated in configuration |
| (Station name).valves.(room).control.mode | R/W (2) | 0 or "off" = no automatic control by pi-controller, the valve is set to 0 1 or "auto"= automatic control. |
| (Station name).valves.(room).control.link | R (1) | if linked valves defined in control configuration this topic shows the name of the master valve, otherwise the topic is not visible |
| (Station name).valves.(room).window.state | W (2) | 0 or "close"= window is closed 1 or "open"= window is open |
| (Station name).valves.(room).window.target | W (2) | valve position (%) when window is open. |
| (Station name).valves.(room).calibration.date | R (1) | calibration date/time of the valve |
| (Station name).valves.(room).calibration.repetitions | R (1) | calibration repetitions of the valve |
| (Station name).valves.(room).diag.meanCurrrent | R (1) | valve mean current |
| (Station name).valves.(room).diag.openCount | R (1) | valve open count during calibration |
| (Station name).valves.(room).diag.closeCount | R (1) | valve close count during calibration |
| (Station name).valves.(room).diag.deadZoneCount | R (1) | valve dead zone count during calibration |
| (Station name).valves.(room).diag.moves | R (1) | valve moves since last calibration |
| (Station name).valves.(room).state | R (1) | 1 = idle 2 = opens 3 = closes 4 = failed (Timeout: maybe the motor is dropped down) 5 = unknown 6 = no valve 7 = full open 8 = connected 9 = blocked (The detected count is less than the configured min. count and the number of repetitions is reached) |
| (Station name).valves.(room).tTarget | R/W (2) | room target temperature |
| (Station name).valves.(room).tValue | R/W (2) | room actual temperature |
| (Station name).valves.(room).target | R/W (1/2) | position (%) of the valve |
(1) if config/protocol/publish 'strict separate topics' is activated then values are published with '/value' added.
E.g. (Station name).common.heatControl/value.
(2) if config/protocol/publish 'strict separate topics' is activated then only write topics are accepted with '/set' added.
E.g. (Station name).common.heatControl/set. These topics are not published by VDMot