Skip to content
 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

19 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

LCSE

           Latent common source extraction (LCSE)

LCSE seeks to construct a common latent representation of the SSVEP signal subspace that is stable across multiple trials of EEG data.

The spatial filter thus obtained improves the signal-to-noise ratio (SNR) of the SSVEP components by removing nuisance signals that are irrelevant to the generalized signal representation learnt from the given data.

This is a sample code for testing LCSE as described in the article [1].

Note: Use the SSVEP benchmark dataset placed in a folder in the same directory as this file

Link: ftp://sccn.ucsd.edu/pub/ssvep_benchmark_dataset/

        Dataset used: SSVEP benchmark dataset [2]

A 40-target SSVEP benchmark dataset recorded from 35 subject. The stimuli were generated by the joint frequency-phase modulation (JFPM) [1]

  • Stimulus frequencies : 8.0 - 15.8 Hz with an interval of 0.2 Hz

  • Stimulus phases : 0pi, 0.5pi, 1.0pi, and 1.5pi

  • No. of channels : 64

  • Selected channels :9 electrodes[ 1(48): Pz, 2(54): PO5, 3(55): PO3, 4(56): POz, 5(57): PO4, 6(58): PO6, 7(61): O1, 8(62): Oz,and 9(63): O2)

  • No. of recording blocks : 6

  • Data length of epochs : 6 s [ 0.5s cue, 5s data, 0.5s blank ]

  • Sampling rate : 250 [Hz]

Data is a 4-D matrix named "data" with dimensions of [64, 1500, 40, 6] The four dimensions indicate, [Electrode_index, Time_points, Target_index, Block_index]

                    Required functions: LCSE

The function has been test only on the SSVEP benchmark dataset described in [2]

[prediction, score] = LCSE(sampling_rate, train_data, test_data, number_of_filterbank, number_of_Reconstructed_channel);

Filter bank coefficients : a = 1.25; b = 0.25; as defined in [1]

            Specification of each input variables

-> sampling rate - EEG data sampling rate (integer value)

-> train_data - data dimension -> [no. of channels, no. of EEG data points, no. of targets, no. of trial blocks]

constraints: no. of channels >=2

no. of EEG data points >= 0.2s of data points

no. of targets >=2

no. of trial blocks >=2

-> test_data - data dimension -> [no. of channels, no. of EEG data points,no. of targets]

constraints: the dimensions of test data should match the corresponding

                  Dimension in the train data

-> number_of_filterbank - should be a interger value between 1 and 7, Refer [1] for further description

-> number_of_Reconstructed_channel - should be a interger value between 1 and no. of trial blocks used for training, Refer [1] for further description

Reference: [1] Kiran Kumar G. R and Ramasubbareddy M, "Latent common source extraction via a generalized canonical correlation framework for frequency recognition in SSVEP based brain–computer interfaces," in Journal of Neural Engineering. doi: https://doi.org/10.1088/1741-2552/ab13d1

Visit my research gate page to download the preprint, link : https://www.researchgate.net/profile/Kiran_Kumar_G_R

[2] Y. Wang, X. Chen, X. Gao and S. Gao, "A Benchmark Dataset for SSVEP-Based Brain–Computer Interfaces", in IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 25, no. 10, pp. 1746-1752, Oct. 2017.

Author: Kiran Kumar G R

Affiliation: Indian Institute of Technology Madras.

email: kirankumar.g.r@hotmail.com

Google Scholar: https://scholar.google.co.in/citations?user=fH96otoAAAAJ&hl=en

Last revised : November 2019

Please send suggestions/queries to the above email