Skip to content
 
 

Repository files navigation

VEDirect

This is a Python library for decoding the Victron Energy VE.Direct text protocol used in their range of MPPT solar charge controllers, battery monitors, and inverters.
This is a forked version of a package originally created by Janne Kario (https://github.com/karioja/vedirect).

Installation

To install directly from GitHub:

$ python3 -m pip install "git+https://github.com/Jordan-seebyte/vedirect-JL"

[NOT SURE IF THIS STILL WORKS] If you have cloned or forked the repo already to your local directory and want to use it in live (editable mode):

$ python3 -m pip install -e "."

If you want to build the repo into a whl file, run the following:

python setup.py bdist_wheel

If you want to build the repo into a tar.gz file, run the following:

python setup.py sdist

If you want to install the built library you can by doing the following:

python -m pip install [LOCATION OF THE TAR>.GZ or the WHL FILE]

Check

Test both command line entry points:

$ vedirect_device_emulator --sph 3600 --n 2
VEDirect emulator running. Writing to <stdout>
b'\r\nV\t12800\r\nVPV\t3350\r\nPPV\t130\r\nI\t15000\r\nIL\t1500\r\nLOAD\tON\r\nRelay\tOFF\r\nH19\t456\r\nH20\t45\r\nH21\t300\r\nH22\t45\r\nH23\t350\r\nERR\t0\r\nCS\t5\r\nFW\t1.19\r\nPID\t0xA042\r\nSER#\tHQ141112345\r\nHSDS\t0\r\nMPPT\t2\r\nChecksum\t\x99'
b'\r\nV\t12800\r\nVPV\t3350\r\nPPV\t130\r\nI\t15000\r\nIL\t1500\r\nLOAD\tON\r\nRelay\tOFF\r\nH19\t456\r\nH20\t45\r\nH21\t300\r\nH22\t45\r\nH23\t350\r\nERR\t0\r\nCS\t5\r\nFW\t1.19\r\nPID\t0xA042\r\nSER#\tHQ141112345\r\nHSDS\t0\r\nMPPT\t2\r\nChecksum\t\x99'
Done

$ vedirect --emulate=mppt --n=2
{'V': 12800, 'VPV': 3350, 'PPV': 130, 'I': 15000, 'IL': 1500, 'LOAD': 'ON', 'Relay': 'OFF', 'H19': 456, 'H20': 45, 'H21': 300, 'H22': 45, 'H23': 350, 'ERR': 0, 'CS': 5, 'FW': '1.19', 'PID': '0xA042', 'SER#': 'HQ141112345', 'HSDS': 0, 'MPPT': 2}
{'V': 12800, 'VPV': 3350, 'PPV': 130, 'I': 15000, 'IL': 1500, 'LOAD': 'ON', 'Relay': 'OFF', 'H19': 456, 'H20': 45, 'H21': 300, 'H22': 45, 'H23': 350, 'ERR': 0, 'CS': 5, 'FW': '1.19', 'PID': '0xA042', 'SER#': 'HQ141112345', 'HSDS': 0, 'MPPT': 2}

Quick Simulation

A simple command line test with a built-in emulator can be performend on any platform without an actual VEDirect device using three commands launching three processes (e.g. in three terminal windows on the same machine):

First, create a pair of virtual serial ports.

$ socat -d -d PTY,raw,echo=0,link=/tmp/vmodem0 PTY,raw,echo=0,link=/tmp/vmodem1
2020/04/13 16:20:43 socat[84720] N PTY is /dev/ttys005
2020/04/13 16:20:43 socat[84720] N PTY is /dev/ttys006
2020/04/13 16:20:43 socat[84720] N starting data transfer loop with FDs [5,5] and [7,7]

Run the VEDirect monitor with the default entry point to display packets to stdio. In this case we note from the above output that we need to listen on /dev/ttys006:

% vedirect --port=/dev/ttys006

Next, run the emulator and set it to write to the first port (in this case /dev/tty005:

% vedirect_device_emulator --port=/dev/ttys005 --model="MPPT" --n=10 --sph=3600
VEDirect emulator eunning. Writing to serial port /dev/ttys005

In the first terminal window, we should begin to see the emulated data printed to stdio:

% vedirect --port=/dev/ttys006
{'V': 12800, 'VPV': 3350, 'PPV': 130, 'I': 15000, 'IL': 1500, 'LOAD': 'ON', 'Relay': 'OFF', 'H19': 456, 'H20': 45, 'H21': 300, 'H22': 45, 'H23': 350, 'ERR': 0, 'CS': 5, 'FW': '1.19', 'PID': '0xA042', 'SER#': 'HQ141112345', 'HSDS': 0, 'MPPT': 2}
{'V': 12800, 'VPV': 3350, 'PPV': 130, 'I': 15000, 'IL': 1500, 'LOAD': 'ON', 'Relay': 'OFF', 'H19': 456, 'H20': 45, 'H21': 300, 'H22': 45, 'H23': 350, 'ERR': 0, 'CS': 5, 'FW': '1.19', 'PID': '0xA042', 'SER#': 'HQ141112345', 'HSDS': 0, 'MPPT': 2}
{'V': 12800, 'VPV': 3350, 'PPV': 130, 'I': 15000, 'IL': 1500, 'LOAD': 'ON', 'Relay': 'OFF', 'H19': 456, 'H20': 45, 'H21': 300, 'H22': 45, 'H23': 350, 'ERR': 0, 'CS': 5, 'FW': '1.19', 'PID': '0xA042', 'SER#': 'HQ141112345', 'HSDS': 0, 'MPPT': 2}
...

You can also emulate vedirect output without using vedirect_device_emulator:

vedirect --emulate=mppt --n=2
{"V": 12800, "VPV": 3350, "PPV": 130, "I": 15000, "IL": 1500, "LOAD": "ON", "Relay": "OFF", "H19": 456, "H20": 45, "H21": 300, "H22": 45, "H23": 350, "ERR": 0, "CS": 5, "FW": "1.19", "PID": "0xA042", "SER#": "HQ141112345", "HSDS": 0, "MPPT": 2}
{"V": 12800, "VPV": 3350, "PPV": 130, "I": 15000, "IL": 1500, "LOAD": "ON", "Relay": "OFF", "H19": 456, "H20": 45, "H21": 300, "H22": 45, "H23": 350, "ERR": 0, "CS": 5, "FW": "1.19", "PID": "0xA042", "SER#": "HQ141112345", "HSDS": 0, "MPPT": 2}

Original README.md

This package was forked from karioja at https://github.com/karioja/vedirect. Below is the original README.md with describes use of some examples in the repo.

The test directory contains a set of live recordings of the serial port data sent by the 3 devices that I own.

  • SmartSolar MPPT 100/20 running firmware version 1.39
  • BlueSolar MPPT 75/15 running firmware version 1.23
  • BVM 702 battery monitor running firmware version 3.08

These recordings can be fed to the Vedirect decoder using a pair of virtual serial ports. To create a pair of virtual serial ports issue the following command:

$ socat -d -d PTY,raw,echo=0,link=/tmp/vmodem0 PTY,raw,echo=0,link=/tmp/vmodem1

This will create 2 virtual serials ports connected to each other. Anything sent to /tmp/vmodem0 will be echoed to /tmp/vmodem1 and vice versa.

Attach the decoder to /tmp/vmodem1

python3 examples/vedirect_print.py --port /tmp/vmodem1

Feed the recording over to /tmp/vmodem0

$ cat test/bvm702.dump > /dev/vmodem0

There is no 1 second delay between the packets as there is with the real hardware. The above commands will flood the terminal with all of the data at once.

About

Simple VE.Direct reader for Python

Resources

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages