Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
开启 TCP KeepAlive 后,现代 .NET 曾将默认 30000/5000 毫秒直接设置为 30000/5000 秒。本修复按维护者决议将正毫秒向上取整为秒(默认30/5秒,1500ms→2s,1ms→1s),采用先减后除避免 int.MaxValue 溢出。保留正数校验、默认关闭和 netstandard2.0 IOControl 毫秒路径;更新选项说明、双语 README 和 Unreleased。
验证:
dotnet build StreamFrame.slnx -c Release:0警告/0错误。dotnet test StreamFrame.slnx -c Release --no-build:net8 129/129、net10 129/129、net48 121/121通过。单位依据:SocketOptionName(秒)、SIO_KEEPALIVE_VALS(毫秒)。
Closes #62