Download configuration and usage statistics from MSA Safety / Sierra Monitor FieldServer BACnet gateways — as a CLI, and as a Python library.

Point it at one FieldServer or a fleet of them, give it one set of credentials, and get a JSON document per device.

Install

uv sync                     # development
uv tool install .           # as a CLI on your PATH

Requires Python 3.10 or newer. The test suite is verified on 3.10, 3.11, 3.12 and 3.13; development happens on 3.13 (.python-version).

If you change the floor, move [tool.ruff] target-version with it — otherwise ruff's UP rules rewrite code into syntax the floor doesn't support.

Credentials

Put them in a .env beside the project (see .env.example); .env is gitignored:

FIELDSERVER_USERNAME=ssi
FIELDSERVER_PASSWORD=...
FIELDSERVER_HOSTS=192.0.2.6,192.0.2.8     # optional default host list

They can equally come from the real environment or --username / --password. CLI flags win over the environment, which wins over .env.

Usage

# Configuration -> out/<host>.json
msa-fieldserver export 192.0.2.6 192.0.2.8

# A whole fleet from a file ('#' comments allowed)
msa-fieldserver export --hosts-file fleet.txt --out-dir snapshots

# Usage statistics -> out/<host>-stats.json
msa-fieldserver stats --hosts-file fleet.txt

# Check one device: reachable? credentials good? which reads does it support?
msa-fieldserver probe 192.0.2.6

Hosts may be bare IPs (192.0.2.6), host:port pairs (localhost:6080, e.g. an SSH port-forward), or full URLs. Bare hosts default to http:// on port 80.

Exit codes: 0 all hosts succeeded, 1 at least one host failed, 2 bad arguments.

Config and statistics are separate on purpose

The device returns port configuration, message counters and the routing table in a single payload. This tool splits them:

  • <host>.json — configuration only. Stable between runs, so diff against a previous snapshot shows real configuration drift.
  • <host>-stats.json — counters, routing table, system status. These move constantly and would otherwise make every config diff noisy.

Partial results are normal

Firmware builds differ in which mesh components they expose, and accounts differ in what they may call. A device that answers some reads and refuses others still produces a document; the failures are listed inline:

{
  "host": "192.0.2.6",
  "product": {"product_name": "BACnet Router", "product_version": "8.0.1"},
  "bacnet_ports": {"ETH1 - BACnet IP Wired 1": {"Network Number": 15051}},
  "errors": [
    {"source": "pe/getFirmwareVersion", "message": "pe/getFirmwareVersion: Access denied"}
  ]
}

Access denied means the account lacks permission for that method, not that the firmware is missing it — the ssi service account is refused several reads on 8.0.1. Use probe to see exactly what a given device and account allow.

If a device returns "Unknown db name bacnet_router"

The unit is almost certainly in Recovery Mode, where the protocol engine's runtime databases are not registered. It needs a reboot; no client-side change will help.

This is worth knowing because the usual health checks miss it — pe.isOnline still returns true and systemStatus still reports "System running smoothly". Only the device's message screen admits it, so probe checks that first and tells you before listing failures that would otherwise look like your problem.

Library

from msa_fieldserver_config import FieldServerClient, collect_config, collect_stats

with FieldServerClient("192.0.2.6", "ssi", password) as fs:
    config = collect_config(fs)
    stats = collect_stats(fs)

    print(config.model_dump_json(indent=2))
    for name, port in stats.ports.items():
        print(name, port.statistics.info, len(port.routing_table), "routes")

    # Anything the wrappers don't cover:
    raw = fs.call("pe", "rpc_db_read_json", db="bacnet_router", path="Ports")

When calling methods directly, the argument style is not cosmetic — it selects the wire envelope, and the device's methods disagree about which they want:

fs.call("pe", "rpc_db_read_json", db="bacnet_router", path="Ports")  # -> {"parameters": {...}}
fs.call("pe", "fsReadMsgScreen", "Errors")  # -> {"parameters": [...]}

Keyword arguments become an options object; positional arguments become an argument array. Methods the UI calls with a bare scalar need the positional form — given an object they reply Invalid selectString: null, which looks like a missing parameter name but isn't.

Fan out over a fleet:

from pathlib import Path
from msa_fieldserver_config import export_hosts

for result in export_hosts(hosts, "ssi", password, Path("out"), kind="config"):
    print(result.host, "ok" if result.ok else result.error)

Everything is Pydantic v2, so .model_dump() / .model_dump_json() work throughout, and unrecognised device fields are preserved rather than dropped.

The configuration file

config.csv comes back already parsed, as ordered sections. Section names repeat — one Connections block per connection — so sections is a list of single-key dicts rather than a mapping, and .section() flattens them:

cfg = config.config_file
for conn in cfg.section("Connections"):
    print(conn["Connection_Name"], conn["Protocol"], conn["Router_Network_Number"])

This is stored configuration rather than runtime state, so it still reads on a device whose protocol engine is in Recovery Mode — making it the most dependable configuration source available.

Read-only

Only read methods are wrapped. The device exposes destructive neighbours on the same components — pe.postConfig, pe.restart, smcNetwork.setNetworkSettings — and reaching those requires deliberately calling fs.call(...). Nothing in this tool's normal operation writes to a device.

A malformed call can crash the device

This is the most important thing to know before extending this client.

Sending pe/getConfig the object envelope — {"parameters": {"filename": "..."}} instead of {"parameters": ["..."]} — does not return a tidy error. It takes the protocol engine down. The web layer then returns plain-text 502 Bad Gateway for every endpoint, including ones that worked a second earlier, for roughly 75 seconds while the engine restarts. Repeat it enough and the unit comes back in Recovery Mode and needs a physical reboot.

The client guards against this: call() refuses to send a known scalar-argument method (pe/getConfig, pe/fsReadMsgScreen) in object form. Keep that list current if you add wrappers — the whole reason it exists is that the failure is silent, delayed, and expensive.

A plain-text 502 from this device usually means the engine just died, not slow down. Retrying harder makes it worse.

Pacing

Requests to one device are paced 0.5s apart by default, and parallelism is across devices rather than within one.

Honest caveat: pacing was originally added to explain the 502s above, and that diagnosis was wrong — there's no evidence these gateways are rate-sensitive, and nine sequential reads at 0.15s spacing were fine. It's kept because the risk is asymmetric: pacing costs seconds, while being wrong about an embedded gateway costs a site visit. Tune it freely once you know a deployment:

msa-fieldserver export --hosts-file fleet.txt --pacing 0.15 --workers 8

--pacing 0 disables it entirely.

Development

uv run pytest                 # tests
uv run pytest --cov           # with coverage
uv run ruff check --fix .     # lint
uv run ruff format .          # format
uv run pyrefly check          # type check (must pass)
uv run pre-commit install     # enable hooks

Before extending the client

The device is a Happner (happn-3) mesh, not a REST API — the web UI drives it over a Primus WebSocket, and the HTTP surface used here is a happner-rest bridge onto the same component exchange. Almost nothing about it is guessable, and /rest/describe is 403, so the API is not self-documenting.

Practical consequences, all learned the hard way against real hardware:

  • Argument shape selects the calling convention — object vs array, and getting it wrong on a scalar-argument method crashes the protocol engine rather than returning an error. See the section above; the guard in client.py exists for exactly this.
  • A plain-text 502 means the engine died, not "slow down". Retrying aggressively compounds it.
  • Access denied is a device-side permission, not a missing feature — it varies by account.
  • Partial documents are normal and are the design, not a fallback.

The mesh exposes 34 components; msa-fieldserver probe is the quickest way to see what a given device and account actually allow. Destructive methods (pe.postConfig, pe.restart, smcNetwork.setNetworkSettings) sit right next to the read methods on the same components, so add wrappers deliberately.

License

MIT — see LICENSE.

Not affiliated with or endorsed by MSA Safety or Sierra Monitor. "FieldServer" is their trademark; this is an independent client built by observing a device's own web interface.

About

Download configuration and usage statistics from MSA Safety / Sierra Monitor FieldServer BACnet gateways. CLI and Python library.

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages