-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathcfg.ini
More file actions
101 lines (84 loc) · 2.44 KB
/
Copy pathcfg.ini
File metadata and controls
101 lines (84 loc) · 2.44 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
[Configuration]
IP = 192.168.178.94
Typ = Beispiel # SolarEdge | Fronius | Kostal_mit_KSEM | Huawei | SMA | Victron | E3DC | Kostal_Plenticore | FroniusFloat | SAX | GoodWe1 | Sungrow | AlphaESS | GoodWe2 | SolarLog
# -------------------------------------
[Beispiel]
# Beispiel: Lese 5 Register ab 30810, dann 1 Register aus 60820 und 1 Register aus 30822
Port = 502
Addr = 1
30810 = 5
60820 = 1
30822 = 1
[SolarEdge] # "cfgInverterType":1
Port = 1502
Addr = 1
40071 = 1 # I_AC_Current
40083 = 2 # AC Power value + AC Power scale factor
40206 = 1 # Total Real Power (sum of active phases)
40210 = 1 # AC Real Power Scale Factor
[Fronius] # "cfgInverterType":2
Port = 502
Addr = 240
40083 = 2 # AC Power value + AC Power scale factor
40087 = 1 # Total Real Power (sum of active phases)
40091 = 1 # AC Real Power Scale Factor
[Kostal_mit_KSEM] # "cfgInverterType":3
Port = 502
Addr = 240
40087 = 1 # Total Real Power (sum of active phases)
40091 = 1 # AC Real Power Scale Factor
[Huawei] # "cfgInverterType":4
Port = 502
Addr = 1
37113 = 2 # Active power
37765 = 2 # [Energystorage]Charge/Discharge power (optional)
[SMA] # "cfgInverterType":5
Port = 502
Addr = 1
30867 = 2 # Metering.GridMs.TotWOut
30865 = 2 # Metering.GridMs.TotWIn
[Victron] # "cfgInverterType":6
Port = 502
Addr = 100
820 = 3 # com.victronenergy.system --> Grid L1 - Power
[E3DC] # "cfgInverterType":7
Port = 502
Addr = 1
40074 = 2 # Leistung am Netzübergabepunkt
[Kostal_Plenticore] # "cfgInverterType":8
Port = 1502
Addr = 71
172 = 2 # Total AC active power
[FroniusFloat] # "cfgInverterType": 9
Port = 502
Addr = 240
500 = 2
40096 = 82
[SAX] # "cfgInverterType": 10
Port = 3600
Addr = 64
47 = 2
[GoodWe1] # "cfgInverterType":11
Port = 502
Addr = 247
36025 = 2 # MeterTotalActivepower
35183 = 1 # Batt Power
[Sungrow] # "cfgInverterType": 12
# benötigt INPUT-Register!
Port = 502
Addr = 1
13009 = 2 #Aktuelle Leistung am Übergabepunkt des Versorgungsnetzes
[AlphaESS] # "cfgInverterType": 13
Port = 502
Addr = 95
33 = 1 # Total Active power (Grid Meter) 0x021 Gesamtwirkleistung (Netzzähler)
294 = 1 # Battery Power 0x126 Batterieleistung
[GoodWe2] # "cfgInverterType":14 (ohne Smart Meter / Speicher)
Port = 502
Addr = 247
35140 = 1 # AC ActivePower in W
[SolarLog] # "cfgInverterType": --- TBD ---
Port = 502
Addr = 1
3502 = 1 # Total AC Power PAC of all Inverters and Meters in inverter mode
3518 = 1 # Current total consumption PAC of all consumption meters