tools

check_manifest.py

Diffs the game's own WEBSERVER_LIST_VARIABLES_JSON against ../data/manifest.json and exits non-zero on any drift, in either direction. Measured at build V 2.2.25.220: 332 GET names, 91 POST names, 388 unique names in their union, zero missing either way.

python3 tools/check_manifest.py                    # live, hits the API
python3 tools/check_manifest.py --fixture F.json    # offline, no network

--fixture PATH reads a saved JSON payload instead of the API, which is what makes this testable without a running game; see tools/test_check_manifest.py. The point of the tool is the same one CONTRIBUTING.md already states for the writable-variables.md generator: a future build that adds, removes or renames a variable should fail the check loudly instead of the map going stale silently.

Duplicate names are checked separately from drift, on the raw list. The drift comparison above is set-based, and a set silently dedups: a name duplicated within one of the four source lists (game GET, game POST, manifest GET, manifest POST) would change what len(list) reports without the set comparison ever seeing it. check_manifest.py compares len(list) against len(set(list)) per side and reports any duplicate names it finds as a distinct DUPLICATE NAMES DETECTED condition, separate from DRIFT DETECTED, and either one is enough to exit non-zero.

probe.py

Measures what a POST actually does, without attributing background drift to your command.

python3 tools/probe.py CONDENSER_VACUUM_PUMP_START_STOP START \
  --watch CONDENSER_VACUUM_PUMP_ACTIVE CONDENSER_VACUUM CONDENSER_PRESSURE \
  --readback CONDENSER_VACUUM_PUMP_ACTIVE

Outputs JSON with a verdict, the effects that survived drift subtraction, and the method parameters used, so a result can be reproduced or disputed.

Verdicts

Verdict Meaning
CONFIRMED The read-back variable now equals the value posted. The strongest result
EFFECT Something moved that did not move during the matched null, but the read-back did not confirm
NO_EFFECT HTTP 200 and nothing attributable moved
NOT_WRITABLE HTTP 404. The name is not in the writable surface
GATED HTTP 412. Writable but behind a consent gate

NO_EFFECT and CONFIRMED are both HTTP 200. That is the entire reason this tool exists: see ../docs/wire-format.md.

Why it is built this way

Each rule below exists because breaking it produced a wrong published result.

Fail closed. Every request resolves to a value, a documented not-found, or an ERROR, and ERROR never collapses into the other two. An earlier harness counted connection failures as successful reads and reported "91 readable, 0 write-only" when the answer was 35 and 56. It looked complete and confident and was inverted.

Multi-sample matched nulls. Before writing anything, the harness samples every watched variable N times with no POST issued, and records which ones move on their own and by how much. A variable that drifted during the null must then exceed twice its observed spread to count as an effect.

A single before/after null pair is not enough. If the signal's period is comparable to the settle window, both samples can land at the same phase of a sawtooth and the variable looks static. That aliasing put three pressure variables into all 10 results of an earlier emergency-control sweep as false positives.

No baked-in constants. Drift rate here is plant-state dependent, not a property of the game. A 140-sample capture found the pressure variables completely static in conditions where an earlier session had measured them falling steadily. Every probe therefore derives its own baseline immediately adjacent in time, and none is reused.

Explicit read-back name. 56 of 91 writable variables are write-only. Pass --readback with the correct twin from ../docs/writable-variables.md, because for most variables you cannot read the name you just wrote.

Positive control on the listener. Reachability is checked with ss, not by attempting a connection. The API binds IPv6 loopback only, so a probe over the wrong address family shares the broken component it is testing and cannot detect its own fault. That produced two 15-minute false "port never bound" reports.

Safety

Two blocklist tiers, both enforced in code rather than by convention:

  • FUN_* is refused unconditionally. These are trigger writes; the act of writing is the action, so the usual "write the current value back" no-op pattern does not exist for them. See ../docs/fun-family.md.
  • CORE_SCRAM_BUTTON, CORE_EMERGENCY_STOP, STEAM_TURBINE_TRIP require --allow-dangerous. Not because they harm the game, but because the API has two working trip paths and no working reset, so an automated caller can abort and cannot recover. See ../docs/emergency-controls.md.

Test writes on a throwaway save.

Before trusting a negative result

Check STEAM_TURBINE_{n}_INSTALLED and the equivalent for other indexed equipment. Uninstalled units return confident, permanently-zero values, so an experiment aimed at one measures nothing while looking like a clean negative.

Do not run immediately after a save load. The webserver unbinds on load and needs re-enabling, and settled values differ sharply from the first readings back.

checklist.py

Tracks the in-game startup checklist (the [C] key) against live telemetry.

python3 tools/checklist.py --loop 3
python3 tools/checklist.py --loop 3 --watch 5

The in-game checklist records what you clicked. This records what the plant is doing. They diverge, and the gap is where the interesting failures live: a command can be stored while the actuator is still slewing, an indexed variable can be null because that fuel bay is empty, and HTTP 200 certifies nothing.

Pass --loop as the in-game loop number. The API index is one lower.

Statuses

Status Meaning
OK Telemetry satisfies the item
DONE Satisfied earlier, now superseded by a later item
SLEWING Ordered value is correct, actual is still travelling
PENDING Not satisfied yet
NO-SIGNAL No API variable exists. Not a pass
NO-REF Observable, but the threshold is not knowable from the API
ERROR Could not read. Never silently treated as pass or fail

NO-SIGNAL is load-bearing, not padding. Activating terminals, the external power switch, the grid startup request and the breaker close have no variable at all, so an automated client can neither perform nor verify them. Surfacing that is the point: it makes the hole in the commandable surface visible instead of implicit.

NO-REF currently covers two items. Retention Tank ~50% has no capacity variable anywhere in the manifest, so a percentage cannot be computed; the raw volume is reported instead of a guess.

Supersession

Several checklist items are staged: bypass goes 100 then 0, MSCV goes 0 then >=25, the startup motive valve goes 100 then 0, the vacuum pump goes STARTUP then OPERATIONAL. Once the later item is satisfied the earlier one legitimately stops matching, and calling that PENDING reads as a regression. Those are reported DONE with the item that superseded them.

Two traps this tool exists to avoid

GENERATOR_{n}_BREAKER carries no information. It reads True on idle and uninstalled units alike.

GENERATOR_{n}_KW is trustworthy exactly when GENERATOR_{n}_A is greater than 0. At zero amps it is a fabricated potential figure. Observed reading 33702 kW at 15.14 Hz with 0 amps. An earlier version of this tool checked kw > 0 and consequently reported a successful grid sync for a generator delivering nothing. The check now uses amps, cross-referenced against grid frequency. With amps above 0, GENERATOR_{n}_KW equals GENERATOR_{n}_V times GENERATOR_{n}_A divided by 1000, exactly, verified across three consecutive samples on a synced machine. See ../docs/value-semantics.md.

Do not reach for POWER_FROM_TURBINE_KW as a substitute reference in either regime. It does not track generation at all, see the same section.

That bug is recorded rather than quietly fixed because it is the same failure this repository keeps documenting: a plausible variable that reads like success.

monitor.py

Steady-state monitor for a running plant. Stays quiet unless something needs an operator.

python3 tools/monitor.py --loop 3 --interval 15
python3 tools/monitor.py --loop 1 --interval 10 --count 20 --log run.tsv
python3 tools/monitor.py --loop 3 --down-threshold 10 --poll 1

--loop selects which secondary loop to watch, 1, 2 or 3. It is not a repeat count. --count is the repeat count, and defaults to 0, meaning run until interrupted, not run zero times.

Read-only. The file contains no write method at all. That absence is the safety guarantee, rather than a flag someone could flip.

Severity levels

Severity Meaning
ERROR A variable could not be read. Never collapses into a healthy reading, except for a wholesale API outage, see below, which is one fact and is reported once
CRIT Needs operator action now
WARN Needs attention, not yet urgent
INFO A condition that would be WARN or CRIT at power, downgraded because regime() has positively established the plant is in startup. Downgraded, not suppressed, it still prints every time

The guards are relational

The two conditions that nearly emptied a secondary loop during testing were both comparisons between variables, and no single-variable limit or rate check could express either:

Guard Condition
Steam balance RETURN_FLOW vs OUTLET. A negative balance with falling inventory is CRIT
Boiling COOLANT_SEC_{n}_TEMPERATURE vs STEAM_GEN_{n}_BOILING_POINT, which moves with pressure
Grid sync amps > 0 checked against frequency and RPM together
Margin core temp and pressure against their own _MAX variables
Integrity with the 70% continuous-bleed threshold called out explicitly

An absolute temperature limit cannot catch "not boiling", because the boiling point is itself a live variable that was observed moving between 215 and 321 within one session.

Gate by regime, don't suppress on doubt

Monitor.regime() classifies the plant as at_power, startup or unknown, the way a real RPS permissive like P-7 gates trips by plant condition: a guard that is correct at power can be wrong during startup, when the checklist calls for MSCV >= 25 and the loop is deliberately unbalanced.

The direction of the gate is the load-bearing part, not its mere existence. unknown gates exactly like at_power, never like startup. Only a positively established startup, both amps and op_mode readable and not consistent with carrying load at NOMINAL, may downgrade a guard to INFO. The risky failure mode for a regime gate is suppression, not over-alerting: a gate that fails open when it cannot read the regime would disarm protection at exactly the moment telemetry has degraded, which is the one moment protection matters most.

The turbine-trip guard is a transition detector, not a latching trip

The turbine-trip guard, the Trip 18 analog covering reactor trip on turbine trip, which Nucleares does not implement, fires by comparing current STEAM_TURBINE_{n}_PRESSURE against the highest pressure this run's own history has seen. It exists because a turbine that never started and a turbine that tripped read identically on pressure alone, and only the history tells them apart.

That history lives in a deque(maxlen=30), so the guard has a finite, bounded memory: once the pre-trip pressure ages out of the window, the guard stops firing even if the turbine is still down. That is intentional. This is a transition detector built to catch the moment of collapse, not a latching trip that remembers a fault forever.

The run-local inventory guard has no plant nominal to compare against

COOLANT_SEC_{n}_LIQUID_VOLUME has no capacity or nominal variable anywhere in the manifest, so a percent-of-nominal guard, the actual Trip 16 form, is not computable (see ../docs/protection-system.md). The guard instead tracks a run-local high-water mark, raised only while the loop looks healthy, at_power with a non-negative balance, and alerts on percent below that mark.

The documented weakness is deliberate, not a bug: if the monitor is started mid-drain and never observes a healthy at-power sample, no reference is ever established, and this guard cannot fire even though the plant is genuinely low. A silent wrong number is worse than no number, so it stays silent instead of guessing. tools/test_monitor.py asserts this behavior directly rather than treating it as an oversight.

Guard the integral, not the derivative

Inventory alerts use level plus net balance, never a rate sampled over one interval. Several of these signals are stepped sawtooths, so a short-window rate is noise: a tank was observed holding a value for 10 s and then jumping.

A deviation that is closing is not an alert

The pressurizer check suppresses its warning when the deviation is already shrinking. A plant correcting itself does not need an operator, and alerting on it trains people to ignore the alert. Observed converging 172.4 to 158.4 across one run with no intervention.

Fail closed

An unreadable variable raises ERROR. It never reads as healthy.

The API outage watch

A monitor instance was once found running 2 hours after the game had exited. It had written 5,740 lines and 370 KB, entirely per-variable [ERROR] unreadable <NAME>: URLError alerts, roughly 24 of them per cycle, one for every watched variable. It never once said the webserver was gone, only that every individual thing it asked for had failed. That is the defect this section closes.

localhost, never 127.0.0.1. Liveness is checked with a plain socket connect, api_alive(), to ("localhost", 8785). The host must resolve through the name, not a hardcoded IPv4 literal: ../docs/wire-format.md documents that this API binds [::1]:8785, IPv6 loopback only. A 127.0.0.1 literal would never reach that socket, so a client hardcoding it would report a permanent false outage regardless of whether the game is actually running. api_alive() replaces the older ss-based check: ss is Linux only, and this gets called on every poll tick for hours at a time, so a subprocess per check is wasted work a plain connect avoids.

The ERROR collapse rule. A wholesale outage and a single bad variable are different facts and must not be conflated. If every entry in one snapshot's error list is a transport-level failure (URLError, timeout, TimeoutError, ConnectionRefusedError, OSError, gaierror, the names read() can produce for a socket/HTTP failure) and there are more than a handful of them, alerts() collapses them to a single API unreachable: all N variables unread (...) ERROR. A single unreadable variable, or a mix of transport and non-transport failures (for example a name that does not exist on this build, alongside real transport failures), is a genuine per-variable signal and is not collapsed, it still gets its own unreadable <NAME>: <reason> line. Hiding that signal inside a summary would be its own kind of going quiet.

Outage duration, WARN below threshold, CRIT beyond it. Monitor.note_liveness() and Monitor.outage_secs() track how long the API has been continuously unreachable, using time.monotonic() rather than wall clock so a suspend/resume or NTP jump cannot corrupt the duration. Below --down-threshold (default 10.0s) the outage alert is WARN, "API unreachable for Ns. Expected briefly during a save load, the webserver unbinds", because the webserver unbinds on save load and a brief outage is benign (../docs/wire-format.md). At or beyond the threshold it escalates to CRIT, "...beyond the Ns threshold. The plant is UNOBSERVED, no guard below is running", because a sustained outage means the game exited or crashed, not a save load, and every guard in this file is silently inert while it is None all the way down. Recovery prints once, "API was unreachable for Ns, readings resumed", on the first snapshot after the API comes back, not on every snapshot afterward.

During an outage alerts() can never return an empty list, that is the whole point: it is what stops main() from printing all guards clear while the plant is actually unobserved. tools/test_monitor.py asserts this directly.

The period-vs-threshold granularity trap. --interval defaults to 15s. A 10s --down-threshold checked only once per snapshot could never actually resolve, an outage can start and fully end inside a single 15s sleep and nobody would ever see it cross the threshold. --poll (default 1.0s) is how often liveness is checked while sleeping between snapshots, independent of --interval, and it is what makes --down-threshold observable at all: a threshold finer than the sample period is decorative unless something polls faster than it samples. If --down-threshold is set finer than --poll, monitor.py warns on stderr at startup rather than exiting, the run is still usable, just coarser than requested.

Running the tests

python3 tools/test_monitor.py
python3 tools/test_check_manifest.py
python3 -m unittest discover -s tools

There are two test files now, one per tool. test_monitor.py runs 48 tests. test_check_manifest.py runs 25 tests. python3 -m unittest discover -s tools runs both together, 73 tests.

A single-file invocation no longer covers the whole suite. Running only test_monitor.py skips check_manifest.py's 25 tests, and running only test_check_manifest.py skips monitor.py's 48. Use discover, or run both files explicitly, to exercise everything.

Bare python3 -m unittest from the repo root discovers 0 tests: tools/ deliberately has no __init__.py, and unittest's default recursive discovery skips directories that are not packages.