Valves: the meta-command indirection

The single biggest structural finding in this repository, and the one that wasted the most time before it was understood.

Valves are not addressed by name

There are exactly three valve POST endpoints:

VALVE_OPEN
VALVE_CLOSE
VALVE_OFF

The value you post is the identifier of the valve you want to act on:

curl -s -X POST --data "" \
  "http://localhost:8785/?Variable=VALVE_OPEN&value=VALVULA_ENTRADA_NUCLEO_01"

Read that as an imperative with an object. VALVE_OPEN is the verb, the valve identifier is the noun. It is not a variable being set to a value.

Why probing for valve names finds nothing

None of the 55 valve identifiers appear as top-level variable names. Verified by set intersection against the full manifest (332 GET plus 91 POST names): 0 overlap.

The identifiers exist only as keys inside VALVE_PANEL_JSON, which is itself an ordinary GET-list member. So the addressing scheme is two levels deep, and the level that matters is not in the variable namespace at all.

There is a second reason naive probing missed them: the identifiers are Spanish engineering names (VALVULA_ENTRADA_NUCLEO_01, Valvula_Pressurizer_Vent), and casing is inconsistent between them. English guesses were never going to land.

Evidence: auto_nuke:lib/auto_nuke/api/valves.ex:322,345-347, which annotates the payload as "value = target ActuatedValve valve_panel_key". That client had the answer in its source the whole time.

Reading valve state

VALVE_PANEL_JSON is also the read-back path. Each identifier maps to:

{
  "AGUA_Valve_01": {
    "Sector": "CHEMICAL TREATMENT ROOM",
    "Actuator": "OFF",
    "Value": 0.0,
    "State": {
      "SituationReached": true,
      "OpeningTargetReached": true,
      "IsOpened": false,
      "IsClosed": true,
      "BypassMode": false,
      "Stuck": false,
      "Flooded": false
    }
  }
}

Value is 0 to 100 opening percent. Actuator is the commanded state (OFF here, meaning no active drive). The State block carries the flags worth guarding on: Stuck, Flooded, BypassMode, and SituationReached.

Note that IsOpened and IsClosed are both false for a partially open valve, so they are not complements. Do not treat one as the negation of the other.

All 55 valve identifiers

Captured live at build V 2.2.25.220. Sector grouping is the game's own.

CHEMICAL TREATMENT ROOM (12)

Identifier Value Opened Closed Actuator
AGUA_Valve_01 0 False True OFF
Boro_Valvula_Purga 0 False True OFF
Camion_Valve_01_Boro 0 False True OFF
Camion_Valve_02_NaOH 0 False True OFF
Camion_Valve_03_Fuel 0 False True OFF
Core_Valve_01 0 False True OFF
Core_Valve_02 0 False True OFF
NAOH_Valve_01 0 False True OFF
NaOH_Valvula_Purga 0 False True OFF
Valve_Q_TANQUE_AGUA 0 False True OFF
Valve_Q_TANQUE_AGUA_CORE_EXTERNO 0 False True OFF
Valve_Q_TANQUE_AGUA_MAIN 0 False True OFF

CONDENSER (13)

Identifier Value Opened Closed Actuator
VALVULA_CON_VACIO_RELIEF 0 False True OFF
VALVULA_ENTRADA_BOMBA_VACIO 100 True False OFF
VALVULA_ENTRADA_CONDENSADOR_01 0 False True OFF
VALVULA_ENTRADA_CONDENSADOR_02 0 False True OFF
VALVULA_ENTRADA_CONDENSADOR_03 100 True False OFF
VALVULA_ENTRADA_EJECTOR_EVA 0 False True OFF
VALVULA_ENTRADA_EJECTOR_TUR 31 False False OFF
VALVULA_RETORNO_CONDENSADOR 0 False True OFF
VALVULA_SALIDA_CONDENSADOR_01 0 False True OFF
VALVULA_SALIDA_CONDENSADOR_02 0 False True OFF
VALVULA_SALIDA_CONDENSADOR_03 100 True False OFF
VALVULA_VACIO_CONDENSADOR 100 True False OFF
VALVULA_VENTEO_TANQUE_RETENCION 0 False True OFF

CORE (15)

Identifier Value Opened Closed Actuator
VALVULA_DRAIN_EVA01 0 False True OFF
VALVULA_DRAIN_EVA02 0 False True OFF
VALVULA_DRAIN_EVA03 0 False True OFF
VALVULA_ENTRADA_NUCLEO_01 0 False True OFF
VALVULA_ENTRADA_NUCLEO_02 0 False True OFF
VALVULA_ENTRADA_NUCLEO_03 100 True False OFF
VALVULA_SALIDA_NUCLEO_01 0 False True OFF
VALVULA_SALIDA_NUCLEO_02 0 False True OFF
VALVULA_SALIDA_NUCLEO_03 100 True False OFF
Valvula_Core_Vent 0 False True OFF
Valvula_Descargar_REF 0 False True OFF
Valvula_Pressurizer_Relief_Vent 0 False True OFF
Valvula_Pressurizer_Spray 100 True False OPEN
Valvula_Pressurizer_Vent 0 False True OFF
Valvula_Purgar_Coolant 0 False True OFF

GENERATOR (13)

Identifier Value Opened Closed Actuator
VALVULA_ENTRADA_TURBINA_01 0 False True OFF
VALVULA_ENTRADA_TURBINA_02 0 False True OFF
VALVULA_ENTRADA_TURBINA_03 5 False False OFF
VALVULA_ENTRE_BC_Y_EVA_01 0 False True OFF
VALVULA_ENTRE_BC_Y_EVA_02 0 False True OFF
VALVULA_ENTRE_BC_Y_EVA_03 100 True False OFF
VALVULA_PURGA_C2_01 0 False True OFF
VALVULA_REF_BYPASS_TUR_CS_01 0 False True OFF
VALVULA_REF_BYPASS_TUR_CS_02 0 False True OFF
VALVULA_REF_BYPASS_TUR_CS_03 0 False True OFF
VALVULA_VENT_TURBINA_01 0 False True OFF
VALVULA_VENT_TURBINA_02 0 False True OFF
VALVULA_VENT_TURBINA_03 0 False True OFF

DIESEL GENERATOR BUILDING (2)

Identifier Value Opened Closed Actuator
ValvulaDeCarga 0 False True OFF
ValvulaPurgadoFuel 0 False True OFF

Total: 12 + 13 + 15 + 13 + 2 = 55.

The three hand valves are not commandable

VALVE_M01_OPEN, VALVE_M02_OPEN and VALVE_M03_OPEN are GET-only telemetry for the plant's manual hand valves. They are in the 332-entry GET list, absent from the 91-entry POST list, and absent from the valve panel. There is no API path to actuate them at all. You can read their position and nothing more.

This closes a question that consumed two full sessions of probing.