Skip to content

Option for rescale_intensities not being applied during uses of N4BiasFieldCorrection #1054

Description

@psadil

What happened?

Pipelines appear to configure N4BiasFieldCorrection to use rescale_intensities , e.g.,

inu_n4_final.inputs.rescale_intensities = True

Unfortunately, without a mask, N4BiasFieldCorrection will always be set to false: https://github.com/ANTsX/ANTs/blob/v2.5.0/Examples/N4BiasFieldCorrection.cxx#L497-L502

    typename itk::ants::CommandLineParser::OptionType::Pointer rescaleOption = parser->GetOption("rescale-intensities");
    if (!isMaskImageSpecified || (rescaleOption && rescaleOption->GetNumberOfFunctions() &&
                                  !parser->Convert<bool>(rescaleOption->GetFunction()->GetName())))
    {
      doRescale = false;
    }

This is also mentioned in the --help

❯ N4BiasFieldCorrection --help | grep "A mask"
          within the user-specified mask. A mask is required to perform rescaling. 

What command did you use?

# check cmdline from dummy run
from nilearn import datasets
from nipype.interfaces.ants import N4BiasFieldCorrection
mni = datasets.fetch_icbm152_2009()
n4 = N4BiasFieldCorrection(dimension=3, rescale_intensities=True, input_image=mni["t1"])
n4.cmdline
# 'N4BiasFieldCorrection -d 3 --input-image /Users/psadil/nilearn_data/icbm152_2009/mni_icbm152_nlin_sym_09a/mni_icbm152_t1_tal_nlin_sym_09a.nii.gz --output mni_icbm152_t1_tal_nlin_sym_09a_corrected.nii.gz -r'

# set up use of cmd with and without mask
cp $FSLDIR/data/standard/MNI152_T1_1mm.nii.gz ./
cp $FSLDIR/data/standard/MNI152_T1_1mm_brain_mask.nii.gz ./

# no mask
❯ N4BiasFieldCorrection -d 3 --input-image MNI152_T1_1mm.nii.gz --output n4-nomask.nii.gz -r
❯ fslstats n4-nomask.nii.gz -R                                                           
0.000000 14616.967773 

# with mask (now scaled now from 0-10000)
N4BiasFieldCorrection -d 3 --input-image MNI152_T1_1mm.nii.gz --output n4.nii.gz -r -x MNI152_T1_1mm_brain_mask.nii.gz 
❯ fslstats n4.nii.gz -R
0.000000 9999.000000

What version of the software are you running?

1.14.2

How are you running this software?

Local installation ("bare-metal")

Is your data BIDS valid?

Yes

Are you reusing any previously computed results?

No

Please copy and paste any relevant log output.

Additional information / screenshots

If this does seem like a valid issue, it may also be a good idea to update nipype to prevent setting rescale_intensities when there is no mask input.