Notifications
You must be signed in to change notification settings - Fork 4
Expand file tree
/
Copy pathdraft_wh_1_adv_availability_forecasting.py
More file actions
100 lines (82 loc) · 6.64 KB
/
Copy pathdraft_wh_1_adv_availability_forecasting.py
File metadata and controls
100 lines (82 loc) · 6.64 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
# -*- coding: utf-8 -*-
"""
Created on Tue Oct 24 08:38:56 2017
super simple water heater model
@author: chuck booten, jeff maguire, xin jin
"""
class WaterHeater():
def __init__(self, Tamb = 50, RHamb= 45, Tmains = 50, hot_draw = 0, control_signal = 'none', Capacity = 50, Type = 'ER', Location = 'Conditioned', service_calls_accepted = 0, max_service_calls = 100, time_step = 60, forecast_draw = 0):
#Declare constants
self.Tdeadband = 1 #delta F
self.E_heat = 4.5 #kW
self.UA = 10 #W/K
self.Tmin = 105 # deg F
self.Tmax = 160 # deg F
self.Capacity = Capacity # gallons
self.max_service_calls = int(max_service_calls)
def execute(self,Ttank, Tset, Tamb, RHamb, Tmains, hot_draw, control_signal, service_calls_accepted, Element_on, timestep, forecast_draw):
(Ttank, Tset, Eused, Eloss, ElementOn, Eservice, SoC, AvailableCapacityAdd, AvailableCapacityShed, service_calls_accepted, is_available_add, is_available_shed) = self.WH(Ttank, Tset,Tamb,Tmains,hot_draw, control_signal, Element_on, service_calls_accepted, self.max_service_calls, timestep, forecast_draw)
return Ttank, Tset, SoC, AvailableCapacityAdd, AvailableCapacityShed, service_calls_accepted, Eservice, is_available_add, is_available_shed, ElementOn
def WH(self,Tlast, Tset, Tamb_ts,Tmains_ts,hot_draw_ts, control_signal_ts, Element_on_ts, service_calls_accepted_ts, max_service_calls, timestep, forecast_draw):
#############################################################################
# Baseline operation
Eloss_ts = self.UA*(Tlast-Tamb_ts)
dT_from_hot_draw = (hot_draw_ts)/self.Capacity*(Tlast - Tmains_ts)# hot_draw is in gal for the timestep
dT_loss = Eloss_ts*timestep*60/(3.79*self.Capacity*4810) #3.79 kg/gal of water, 4810 is J/kgK heat capacity of water, timestep units are minutes
if Tlast < Tset - self.Tdeadband:
Eused_baseline_ts = self.E_heat*1000 #W used
Element_on_ts = 1
elif Element_on_ts == 1 and Tlast < Tset + self.Tdeadband:
Eused_baseline_ts = self.E_heat*1000 #W used
Element_on_ts = 1
else:
Eused_baseline_ts = 0
Element_on_ts = 0
###########################################################################
#modify operation based on control signal
if control_signal_ts[1] < 0 and Tlast > self.Tmin and max_service_calls > service_calls_accepted_ts and Element_on_ts == 1: #Element_on_ts = 1 requirement eliminates free rider situation
Eused_ts = 0 #make sure it stays off
Element_on_ts = 0
service_calls_accepted_ts += 1
elif control_signal_ts[1] < 0 and Tlast < self.Tmin:
# don't change anything
Eused_ts = Eused_baseline_ts
elif control_signal_ts[1] > 0 and Tlast > self.Tmax:
Eused_ts = 0 #make sure it stays off
Element_on_ts = 0
elif control_signal_ts[1] > 0 and Tlast < self.Tmax and max_service_calls > service_calls_accepted_ts and Element_on_ts == 0: #Element_on_ts = 0 requirement eliminates free rider situation
#make sure it stays on
Eused_ts = self.E_heat*1000 #W used
Element_on_ts = 1
service_calls_accepted_ts += 1
else:#no changes
Eused_ts = Eused_baseline_ts
#calculate energy provided as a service, >0 is load add, <0 load shed
# if the magnitude of the service that could be provided is greater than what is requested, just use what is requested and adjust the element on time
# print('Available',abs(Eused_ts-Eused_baseline_ts), 'requested',control_signal_ts[1])
if abs(Eused_ts-Eused_baseline_ts) > abs(control_signal_ts[1]):
Eservice_ts = control_signal_ts[1]
Eused_ts = control_signal_ts[1] + Eused_baseline_ts
Element_on_ts = control_signal_ts[1]/(Eused_ts-Eused_baseline_ts)
else: # assumes WH can't meet the entire request so it just does as much as it can
Eservice_ts = Eused_ts-Eused_baseline_ts
#could change this at some point based on signals
Tset_ts = Tset
dT_power_input = Eused_ts*timestep*60/(3.79*self.Capacity*4810)#timestep is in minutes so mult by 60 to get seconds
Ttank_ts = Tlast + dT_power_input - dT_loss - dT_from_hot_draw
# Calculate more parameters to be passed up
SOC = (Ttank_ts - self.Tmin)/(self.Tmax - self.Tmin)
######################################################################################
#simple method to forecast availability for providing a service during next timestep
# isAvailable_ts = 1 if max_service_calls > service_calls_accepted_ts else 0
#more advanced method for estimating availaibility based on the aggregator providing a fleet average water draw for the next timestep.
dT_from_forecast_draw = -(forecast_draw)/self.Capacity*(Ttank_ts - Tmains_ts)
Ttank_forecast = Ttank_ts + dT_from_forecast_draw
isAvailable_add_ts = 1 if max_service_calls > service_calls_accepted_ts and Ttank_forecast < self.Tmax and (Ttank_forecast > Tset - self.Tdeadband and Element_on_ts == 0 or Ttank_forecast > Tset + self.Tdeadband) > 0 else 0 #haven't exceeded max number of calls, plus it isn't expected that the element would already be on due to the forecast temperature being below Tset- Tdeadband but are still expected to be below Tmax
isAvailable_shed_ts = 1 if max_service_calls > service_calls_accepted_ts and Ttank_forecast > self.Tmin and (Ttank_forecast < Tset + self.Tdeadband and Element_on_ts > 0 or Ttank_forecast < Tset - self.Tdeadband) > 0 else 0 #haven't exceeded max number of calls, plus it is expected that the element would already be on due to the forecast temperature being below Tset + Tdeadband but are still expected to be above Tmin
######################################################################################
Available_Capacity_Add = (1-SOC)*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_add_ts/(timestep*60) #/timestep converts from Joules to Watts, 3.79 = kg/gal, 4180 heat cap of water J/kgK
Available_Capacity_Shed = SOC*self.Capacity*3.79*4180*(self.Tmax - self.Tmin)*isAvailable_shed_ts/(timestep*60) #/timestep*60 converts from Joules to Watts,
return Ttank_ts, Tset_ts, Eused_ts, Eloss_ts, Element_on_ts, Eservice_ts, SOC, Available_Capacity_Add, Available_Capacity_Shed, service_calls_accepted_ts, isAvailable_add_ts, isAvailable_shed_ts
if __name__ == '__main__':