ASTM E 1049 vs. 4-Point Counting Method

Overview

This library implements two rainflow counting algorithms:

  • 4-Point Method (DIN 45667 / FVA-Richtlinie) - Examines 4 consecutive turning points
  • ASTM 3-Point Method (ASTM E 1049) - Examines 3 consecutive turning points

The methods differ in their approach to cycle detection and handling of the first turning point, which leads to different cycle counts when a cycle range includes the first turning point of the measurement.

ASTM E 1049 Standard

Background

ASTM E 1049 - "Standard Practices for Cycle Counting in Fatigue Analysis" (2011 revision) is a comprehensive standard that describes multiple cycle counting methods:

  • Range counting
  • Peak counting
  • Level crossing counting
  • Rainflow counting (3-point method)

The rainflow counting method in ASTM E 1049 uses a 3-point algorithm with special handling for cycles that include the first turning point.

4-Point Method (DIN 45667)

How It Works

The 4-point algorithm examines four consecutive turning points (A, B, C, D) to determine if points B and C form a closed cycle:

           * D
          / \
   B *<--/          Closed if:
    / \ /           min(B,C) >= min(A,D) &&
   /   * C          max(B,C) <= max(A,D)
\ /
 * A

Implementation (from cycle_find_4ptm()):

while( rfc_ctx->residue_cnt >= 4 )
{
    size_t idx = rfc_ctx->residue_cnt - 4;

    unsigned A = rfc_ctx->residue[idx+0].cls;
    unsigned B = rfc_ctx->residue[idx+1].cls;
    unsigned C = rfc_ctx->residue[idx+2].cls;
    unsigned D = rfc_ctx->residue[idx+3].cls;

    // Sort B,C and A,D for min/max comparison
    if( B > C ) { swap(B, C); }
    if( A > D ) { swap(A, D); }

    // Check closure condition
    if( A <= B && C <= D )
    {
        // Cycle B-C is closed
        // Count cycle and remove B,C from residue
        ...
    }
    else break;
}

Algorithm Steps:

  1. Read the last four turning points from residue: A, B, C, D
  2. Sort to get min/max: min(B,C), max(B,C), min(A,D), max(A,D)
  3. Check closure condition: min(A,D) <= min(B,C) && max(B,C) <= max(A,D)
  4. If closed:
    • Count cycle B-C (full cycle)
    • Remove B and C from residue
    • Repeat from step 1
  5. If not closed, stop checking (new turning point needed)

Characteristics:

  • Always counts closed cycles as full cycles
  • Simple closure condition
  • No special handling for first turning point

ASTM 3-Point Method

How It Works

The ASTM method examines only three consecutive turning points (A, B, C) and compares their ranges:

   B *              Range Y = |A - B|
    / \             Range X = |B - C|
   /   \
\ /     \ /         Closed if: X >= Y
 * A     * C

Implementation (from cycle_find_astm()):

while( rfc_ctx->residue_cnt >= 3 )
{
    size_t idx = rfc_ctx->residue_cnt - 3;

    unsigned A = rfc_ctx->residue[idx+0].cls;
    unsigned B = rfc_ctx->residue[idx+1].cls;
    unsigned C = rfc_ctx->residue[idx+2].cls;
    unsigned Y = abs( (int)A - (int)B );  // Range Y
    unsigned X = abs( (int)B - (int)C );  // Range X

    // Check closure condition
    if( X >= Y )
    {
        rfc_value_tuple_s *Z = &rfc_ctx->residue[0];  // First TP

        // Does range Y include the first turning point Z?
        if( (Z->cls >= A && Z->cls <= B) ||
            (Z->cls >= B && Z->cls <= A) )
        {
            // Count as HALF cycle
            cycle_process_counts(...);
            // Remove only A (one point)
            residue_cnt--;
        }
        else
        {
            // Count as FULL cycle
            cycle_process_counts(...);
            // Remove A and B (two points)
            residue_cnt -= 2;
        }
    }
    else break;
}

Algorithm Steps:

  1. Read the last three turning points from residue: A, B, C
  2. Calculate ranges: Y = |A - B|, X = |B - C|
  3. Check closure condition: X >= Y
  4. If closed:
    • Check if range Y includes the first turning point Z
    • If Y includes Z: count as half cycle, remove only A
    • If Y does not include Z: count as full cycle, remove A and B
    • Repeat from step 1
  5. If not closed, stop checking (new turning point needed)

Special Handling of First Point (Z):

The ASTM method has unique handling for cycles that "wrap around" to include the first turning point of the measurement:

  • If the cycle range includes Z, it's counted as a half cycle (0.5)
  • This prevents double-counting when the signal is repeated or periodic

Key Differences

Comparison Table

Aspect 4-Point (DIN 45667) 3-Point (ASTM E 1049)
Points examined 4 (A, B, C, D) 3 (A, B, C)
Closure condition min(A,D) <= min(B,C) && max(B,C) <= max(A,D) |B-C| >= |A-B|
Cycle counting Always full cycles Full or half cycles
First point handling No special handling Half-cycle if included
Points removed Always 2 (B and C) 1 or 2 depending on Z
Minimum residue 4 points 3 points

Half-Cycle Counting (ASTM Only)

The ASTM method counts cycles as half-cycles (0.5) when the cycle range includes the first turning point of the measurement. This is intended to handle edge effects at measurement boundaries.

When half-cycles occur:

A cycle A-B is counted as 0.5 instead of 1.0 when the range [min(A,B), max(A,B)] contains the value of the first turning point Z.

DIN 45667 with Repeated Residue

The 4-point method (DIN 45667) does not have built-in half-cycle counting. However, it achieves correct edge handling through a different mechanism: the Repeated residue method (RFC_RES_REPEATED).

When using RFC_RES_REPEATED, the algorithm:

  1. Appends the residue to itself (simulating signal repetition)
  2. Extracts additional full cycles from the doubled residue
  3. These cycles are counted as full cycles (weight 1.0)

This approach is intuitive and physically meaningful: The results are exactly equivalent to actually repeating the time series. This makes the Repeated method ideal for extrapolation scenarios where a measured load sequence represents a repeating pattern (e.g., one revolution, one duty cycle).

Comparison with ASTM:

  • ASTM: Counts affected cycles as 0.5 during normal processing
  • DIN + Repeated: Counts all extracted cycles as full cycles (1.0)

The key difference: DIN 45667 with RFC_RES_REPEATED counts cycles from the residue as full cycles, while ASTM counts edge-affected cycles as half-cycles. This leads to higher damage estimates with DIN 45667.

Extrapolation Behavior:

When extrapolating results (multiplying cycle counts for longer service life), the methods behave very differently:

  • DIN + Repeated: Scales correctly. If the time series is repeated N times, the damage scales by factor N. The residue handling produces more accurate results.
  • ASTM: Underestimates damage increasingly with higher extrapolation factors. The half-cycles at the boundaries remain at 0.5 regardless of repetition count, while physically they should contribute more damage with each repetition.

Example:

Consider a measurement representing one machine cycle, extrapolated to 1000 cycles:

  • DIN + Repeated: Residue cycles counted as 1.0 × 1000 = 1000 cycles
  • ASTM: Edge cycles counted as 0.5, remaining 0.5 even after extrapolation

The ASTM underestimation grows proportionally with the extrapolation factor.

Damage Estimation Comparison:

Scenario ASTM 3-Point DIN 4-Point + Repeated
Edge-affected cycles Counted as 0.5 Full cycles (1.0)
Residue cycles Some counted as 0.5 All counted as 1.0
Extrapolation Underestimates (error grows with factor) Scales correctly (physically accurate)
Total damage Tends to underestimate Slightly conservative
Safety margin Lower Higher (preferred)

For fatigue analysis, a slightly conservative result (higher damage estimate) is generally preferred over underestimation, making the DIN 45667 method with RFC_RES_REPEATED the safer choice for critical applications.

Algorithmic Complexity

Both algorithms have similar complexity:

  • Time Complexity: O(n) for n turning points
    • Each turning point is processed once
    • Cycle extraction may require multiple iterations, but total work is O(n)
  • Space Complexity: O(r) where r is residue size
    • Both methods maintain a residue buffer
    • Residue size bounded by 2 × class_count in worst case

Both methods process the residue from the end without backtracking.

Result Equivalence

Same Cycles, Different Counting

For signals where no cycle includes the first turning point, both methods produce identical results.

The only difference occurs when a cycle's range includes the first point:

  • 4-Point: Counts as 1.0 (full cycle)
  • ASTM: Counts as 0.5 (half cycle)

Example where results differ:

Signal: [5, 10, 0, 15, 5]
        Z=5 (first point)

Cycle found: (10, 0) with range 10

Range [0, 10] includes Z=5

4-Point result: 1.0 full cycle
ASTM result:    0.5 half cycle

For most practical signals (especially long measurements), the difference is negligible since only cycles near the measurement boundaries are affected.

Important Note on Damage Estimation:

When comparing total damage results:

  • ASTM tends to underestimate damage due to half-cycle counting
  • DIN 45667 with RFC_RES_REPEATED provides a more conservative estimate

For safety-critical applications, the slightly higher damage estimate from DIN 45667 + Repeated residue is preferred, as it provides a safety margin against fatigue failure.

Verification

rfc_ctx_s ctx_4pt, ctx_astm;

// Initialize both with same parameters
RFC_init(&ctx_4pt, 100, 1.0, 0.0, 1.0, RFC_FLAGS_DEFAULT);
RFC_init(&ctx_astm, 100, 1.0, 0.0, 1.0, RFC_FLAGS_DEFAULT);

// Set counting methods
ctx_4pt.counting_method = RFC_COUNTING_METHOD_4PTM;
ctx_astm.counting_method = RFC_COUNTING_METHOD_ASTM;

// Feed same data
RFC_feed(&ctx_4pt, data, data_len);
RFC_feed(&ctx_astm, data, data_len);

// Finalize
RFC_finalize(&ctx_4pt, RFC_RES_IGNORE);
RFC_finalize(&ctx_astm, RFC_RES_IGNORE);

// Compare - may differ slightly due to half-cycle counting
printf("4-Point: full=%.1f, half=%.1f\n",
       ctx_4pt.full_inc, ctx_4pt.half_inc);
printf("ASTM:    full=%.1f, half=%.1f\n",
       ctx_astm.full_inc, ctx_astm.half_inc);

When to Use Each Method

Use 4-Point Method When:

  • Simplicity is preferred - No half-cycle complexity
  • DIN 45667 compliance - German standard requirement
  • FVA-Richtlinie compliance - German drive technology guideline
  • All cycles should be full - No half-cycle counting desired
  • Conservative damage estimate - Use with RFC_RES_REPEATED for safety
  • Default choice - This is the library default

Use ASTM Method When:

  • ASTM E 1049 compliance - US standard requirement
  • Half-cycle distinction needed - Separate full/half cycle counts

Recommendation:

For safety-critical fatigue analysis, use the 4-point method (DIN 45667) with RFC_RES_REPEATED residue handling. This combination provides:

  • Correct handling of edge/boundary cycles
  • Slightly conservative damage estimates
  • No risk of underestimating fatigue damage

Implementation in This Library

Enabling Methods

Compile-Time (ASTM support is optional):

cmake -S. -Bbuild -DRFC_ASTM_SUPPORT=ON

C Code:

rfc_ctx_s ctx;
RFC_init(&ctx, 100, 1.0, 0.0, 1.0, RFC_FLAGS_DEFAULT);

// Use 4-point method (default)
ctx.counting_method = RFC_COUNTING_METHOD_4PTM;

// Or use ASTM method
ctx.counting_method = RFC_COUNTING_METHOD_ASTM;

RFC_feed(&ctx, data, data_len);
RFC_finalize(&ctx, RFC_RES_REPEATED);

C++ Code:

Rainflow::Rainflow rf;
rf.init(100, 1.0, 0.0, 1.0);

// Use ASTM method
rf.ctx_get().counting_method = RF::RFC_COUNTING_METHOD_ASTM;

rf.feed(data, data_len);
rf.finalize(Rainflow::RFC_RES_REPEATED);

Available Methods

typedef enum rfc_counting_method
{
    RFC_COUNTING_METHOD_NONE       = 0,  // No counting
    RFC_COUNTING_METHOD_4PTM       = 1,  // 4-point method (default)
    RFC_COUNTING_METHOD_HCM        = 2,  // HCM method (Clormann/Seeger)
    RFC_COUNTING_METHOD_ASTM       = 3,  // ASTM 3-point method
    RFC_COUNTING_METHOD_DELEGATED  = 4,  // Custom delegate function
} rfc_counting_method_e;

Standards Compliance

4-Point Method Complies With:

  • DIN 45667 - German standard for load spectrum classification
  • FVA-Richtlinie - German drive technology association guideline
  • Most European fatigue analysis standards

ASTM Method Complies With:

  • ASTM E 1049-85 (2011) - US standard for cycle counting
  • SAE fatigue analysis recommendations
  • Many aerospace industry requirements

See Also

References

ASTM E 1049-85 (2011)
"Standard Practices for Cycle Counting in Fatigue Analysis" ASTM International, West Conshohocken, PA
DIN 45667:2010
"Classification counting methods for one-parameter and two-parameter random loadings"
FVA-Richtlinie (2010)
"Zählverfahren zur Bildung von Kollektiven und Matrizen aus Zeitfunktionen" Forschungsvereinigung Antriebstechnik e.V.
Clormann & Seeger (1985)
"Rainflow-HCM / Ein Hysteresisschleifen-Zählalgorithmus auf werkstoffmechanischer Grundlage" TU Darmstadt

For implementation details:

  • rainflow.c (cycle_find_4ptm())
  • rainflow.c (cycle_find_astm())