Quick Update Guide - Version 1.0.2

Critical Fix: Time Sync Now Works Correctly

If you installed version 1.0.0 or 1.0.1, the time sync was setting the wrong date (January 1st). Please update immediately.

What Was Wrong?

The timestamp was being encoded in big-endian instead of little-endian, causing the device to misinterpret the time. This has been fixed in version 1.0.2.

How to Update

Option 1: Replace Just the Fixed File (Fastest)

# Navigate to your integration directory
cd /config/custom_components/switchbot_meter_time_sync

# Backup the old file (optional)
cp coordinator.py coordinator.py.backup

# Replace with new version
# (Upload the new coordinator.py from version 1.0.2)

# Restart Home Assistant
ha core restart

Option 2: Full Reinstall (Recommended)

# Remove old version
rm -rf /config/custom_components/switchbot_meter_time_sync

# Restart to clear cache
ha core restart

# Copy new version
cp -r /path/to/new/switchbot_meter_time_sync /config/custom_components/

# Restart again
ha core restart

Option 3: Via File Editor (Home Assistant OS)

If you're using the File Editor add-on:

  1. Navigate to /config/custom_components/switchbot_meter_time_sync/coordinator.py
  2. Find line 91 (around line 91):
    command.extend(struct.pack('>I', timestamp))
  3. Change it to:
    command.extend(struct.pack('<I', timestamp))
  4. Find line 83 comment and update it too:
    # Format: 0x57 (magic) + 0x09 (time cmd) + 0x01 (subcmd) + timestamp (4 bytes, LITTLE endian)
  5. Save the file
  6. Restart Home Assistant: Settings → System → Restart

Verify the Fix

After updating:

  1. Press the time sync button
  2. Check your SwitchBot Meter display
  3. The time should now show the current date and time
  4. No longer showing January 1st at 2:00 AM

What Changed Technically?

Before (Wrong):

struct.pack('>I', timestamp)  # Big-endian

After (Correct):

struct.pack('<I', timestamp)  # Little-endian (BLE GATT standard)

The > means big-endian (most significant byte first)
The < means little-endian (least significant byte first)

BLE GATT protocol requires little-endian for multi-byte fields.

No Other Changes Needed

  • Your device configuration stays the same
  • Automations continue to work
  • No need to re-add the device

Just update the file and restart!