Skip to content

Complete electrical and thermal safety review #6

Description

@ReidSurmeier

The wiring packet records two 5 V supplies, protective earth distribution, relay-switched LED-panel power, an always-on controller supply, three fans, an AHT20 sensor, and six panels. Documentation is not a substitute for a qualified physical inspection.

Human safety review:

  • verify protective-earth continuity to both power supplies and exposed conductive parts
  • confirm conductor gauges, fusing, strain relief, terminal torque, polarity, clearance, and enclosure airflow
  • measure steady-state and startup current on controller and display branches
  • test relay isolation, START and STOP behavior, UPS power-loss behavior, and thermal response under representative load
  • decide whether a physical thermal cutoff is required

Acceptance criteria:

  • dated measurements and inspector identity are preserved in approved records
  • any unsafe condition blocks public operation until corrected
  • resulting wiring or threshold changes update the BoM, diagram source, generated artifacts, tests, and conservation manual.

Metadata

Metadata

Assignees

No one assigned

    Labels

    enhancementNew feature or requestready-for-humanRequires physical, artistic, rights, or safety judgment

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet