First of all, a big thank you for providing this excellent tool, so well made! This is excellent even for a casual user who would like some opacity information but without having to download huge amounts of data and/or go through installation processes (often with incompatibilities, issues with paths in set-up files,etc.). And thanks for the high resolution!
I have come across a few issues using https://marfa.app:
2440 — 2490
125
100 or 999 K
0.1 or 1 bar
absorption cross-section
Here are some suggestions for web program:
2440.00000 4.3218765e-25
2440.00049 4.3467498e-25
2440.00098 4.3716216e-25
2440.00146 4.3964939e-25
…
instead of 2440.0005, 2440.0010, etc..
About your paper (https://arxiv.org/abs/2411.03418)[https://arxiv.org/abs/2411.03418]:
But once again, congratulations on an excellent service and a really well-made website (lightweight, easily legible, numbers stay in the fields, etc.)!
First of all, a big thank you for providing this excellent tool, so well made! This is excellent even for a casual user who would like some opacity information but without having to download huge amounts of data and/or go through installation processes (often with incompatibilities, issues with paths in set-up files,etc.). And thanks for the high resolution!
I have come across a few issues using https://marfa.app:
Output.datis shifted in wavelength (i.e. the shape is correct but the nu values are wrong, so of course the curve is effectively), which is a big problem because everything looks fine otherwise. It took me some time to figure out what was going on.Error occurred while running MARFA executable.Error occurred while running MARFA executablewith the following settings:******ininfo.txtbut 999 K is ok :)nanat least in the range 2465 to 2470 cm-1. I would understand 0 butnanseems strange.Here are some suggestions for web program:
instead of 2440.0005, 2440.0010, etc..
info.txt, add the units of the cut-off. By the way, what do you think of the recommendation of Gharib-Nehzad et al. 2024 to use 25 cm-1 as a default value for the cut-off?info.txtand on the download summary page, the units of "Absorption cross-section" are given as cm2 but it should be cm2/molOutput.datfile is ~600 kB but the.ptbinfile is ~20 MB, which takes up too much space.Output.datwere commented out with#.About your paper (https://arxiv.org/abs/2411.03418)[https://arxiv.org/abs/2411.03418]:
But once again, congratulations on an excellent service and a really well-made website (lightweight, easily legible, numbers stay in the fields, etc.)!