How it works

Some information stated in this document may be incorrect, this document is the result of my reverse engineering.

Control channel

Fan control is not a memory region you can poke. It is a command protocol on a private pair of I/O ports, independent of the ACPI EC (0x62/0x66) and of the OEM host interface (0x6C/0x68).

port role
0x25C data
0x25D command and status

Status bits on 0x25D: 0x01 OBF (a byte is waiting to be read), 0x02 IBF (input buffer busy, do not write).

A transaction is: drain any stale output, wait for IBF to clear, write the preamble 0xFF to the command port, write the command, then write each payload byte to the data port, waiting for IBF between bytes. For a read, wait for OBF and take the result from the data port.

Two commands matter:

command payload meaning
0xBB 50 table version, one byte returned
0xDD <selector> <register> <value> register table access

In the selector byte, bit 7 selects the direction: 0x02 reads from table 2, 0x82 writes to it.

So reading register 0x30 is DD 02 30 00, and writing 140 to register 0x35 is DD 82 35 8C.

Registers

All in table 2, all reached with command 0xDD.

reg name access range notes
0x30 fan count R 2 constant; used as a liveness check before any write
0x31 fan control mode R/W 0 / 1 0 = EC's own curve, 1 = manual. Global
0x32 fan select W 01 chooses which fan 0x33/0x34/0x35 refer to
0x33 tachometer, low byte R
0x34 tachometer, high byte R rpm = (0x34 << 8) | 0x33
0x35 PWM duty R/W 0255 per fan

Two properties are easy to get wrong:

0x31 is global. It is one bit for the whole controller, not one per fan. Clearing it while fan 1 is selected releases fan 0 as well. Consequently --fan does not confine the effect of a write.

Entering manual mode freezes both fans wherever the EC's curve last put them. set X --fan 0 therefore means "freeze both fans, and give fan 0 the value X" - the fan you did not name stops responding to temperature and sits at whatever duty it happened to have.

While 0x31 is 0, register 0x35 belongs to the controller. It writes its own computed duty there and overwrites anything the host puts in. Reading it in that state is useful telemetry: it shows what the EC's curve is currently doing.

Setting a fan

DD 82 32 <index>       select the fan
DD 82 31 01            manual mode
DD 82 32 <index>       re-assert the selection
DD 82 35 <duty>        duty 0-255

Order matters. A duty written while 0x31 is still 0 gets overwritten by the EC's curve before manual mode engages - the vendor software writes in the opposite order and has this bug.

The selector is written twice on purpose. Coming out of automatic mode, a duty write has been observed landing on the wrong fan, as if the mode write had cleared the selection. Re-asserting it costs one transaction and removes the failure.

Releasing is the mode register alone, and nothing else:

DD 82 31 00            leave the duty untouched

Reading fan speed

Two independent paths:

  • Registers 0x34 and 0x33 over the ports, three transactions per fan.
  • The aperture, a read-only mirror of the controller's RAM in host physical memory. Fan speeds sit at 0xFEDD8B7C and 0xFEDD8B7E as big-endian 16-bit values, ready to use.

The aperture is the better source for telemetry: two bytes at roughly 1.2 µs each, no transaction, no contention with writes. fan-info reads both and compares them - that comparison is the validation test.

Temperature

Temperature is never written and never read over the control ports. It comes entirely from the aperture, one byte per sensor:

field address meaning confidence
CTMP 0xFEDD8358 CPU temperature, whole °C confirmed
CLOT 0xFEDD8301 second sensor, whole °C name only

CTMP is confirmed by the machine's own ACPI tables. The thermal zone's _TMP method reads that exact byte and converts it with TTMP = CTMP * 10 + 2732, which is degrees Celsius turned into tenths of a kelvin. That pins down the location, the unit and the fact that the rest of the system trusts the same number.

CLOT is declared in the ACPI field but never read by anything, so its meaning rests on the field name alone. Treat it as unverified.

Practical notes:

  • One unsigned byte. Whole degrees, no fractions, no negatives. Do not expect it to agree with k10temp to the decimal - that driver reads the CPU's own registers over a completely different path.
  • The refresh rate belongs to the EC. Reading a hundred times a second gets you nothing that reading once a second does not.
  • The controller does not measure the CPU. It receives that number from the SoC and stores it. You are reading the EC's picture of the world.

You cannot set a temperature. What the curve does is map a temperature to a percent, convert that to a duty with duty = round(percent * 255 / 100), and write the duty. --sensor chooses which of the two readings drives the mapping: cpu, board, or max (the default, and the safer choice with two sensors on one curve).


The vendor path on Windows

Recorded for comparison, and as the origin of the findings above.

HealthyTable_SetFanPwmDuty(duty)              AsusWinIO64.dll, RVA 0x28AE0
  └─ RwEcCmd(len, cmd, buf, dir, &status)     RVA 0x200D0
       └─ DeviceIoControl(\\.\AsusSAIO,
                          0x80102070,
                          req, 16, req, 16)
            └─ IOCTL dispatch                 AsusSAIO.sys, RVA 0x12A0
                 └─ handler                   RVA 0x1AA0
                      └─ transaction core     RVA 0x1828
                           └─ port write      RVA 0x1D70
                                └─ out dx, al RVA 0x1DCB

The 16-byte request structure, same buffer in and out:

offset type field
0x00 u8 command code, 0xBB or 0xDD
0x01 u8 payload length, 1–8
0x02 u8[8] payload
0x0A u8 direction: 1 expects a returned byte, 0 is a write
0x0B u8 byte returned by the EC
0x0C u32 status, 0 = OK, 0x102 = timeout

The library needs SYSTEM, not merely administrator, and the ASUS System Analysis service has to be running.

  • 0x12A0 is the IOCTL dispatcher. It compares the control code against a list; cmp eax, 0x80102070 sits at 0x1367 and branches to 0x13F7.
  • 0x13F7 rejects the request unless both buffers are at least 0x10 bytes, copies 16 bytes in, calls 0x1AA0, copies 16 bytes back and sets Information = 0x10. This is where the 16 bytes, same buffer both ways claim comes from.
  • 0x1AA0 unpacks the structure exactly as tabulated: command from [buf], length from [buf+1], payload pointer buf+2, direction from [buf+0xA], status pointer buf+0xC; after calling 0x1828 it stores the returned byte at [buf+0xB]. The call is bracketed by KeWaitForSingleObject and KeReleaseMutex - the serialising mutex is real, and any independent implementation needs its own.
  • 0x1828 is the transaction core and carries the port numbers as literals: mov edx, 0x25c, and mov edx, 0x25d paired with mov cl, 0xff - the preamble byte written to the command port.
  • 0x1734 is the status-bit wait. It polls at most 0x3E8 = 1000 times and returns 0x102 on expiry. Each iteration calls a helper at 0x1000 that wraps KeDelayExecutionThread with a relative interval of arg × -10 in 100 ns units; the caller passes 0x64 = 100, so 100 µs per poll. The POLL_LIMIT and POLL_DELAY constants in this program are the same numbers, arrived at independently.
  • 0x1D70 is a generic port write that switches on a width byte: 1 → out dx, al at 0x1DCB, 2 → out dx, ax, 4 → out dx, eax.

Two imports are worth noting. MmMapIoSpace / MmUnmapIoSpace are the driver's own route to the telemetry aperture - the same physical page this program maps through /dev/mem. IoGetCurrentProcess, ZwOpenProcessTokenEx, ZwQueryInformationToken and RtlEqualSid are the caller check that makes administrator insufficient: the driver compares the calling token's SID rather than checking for elevation.