In a recent update of the integration an input has been added Smart Grid which is an on/off toggle. When Smart Grid is enabled, it has four operating modes.
References: (Bundesverband Wärmepumpe, BWP) https://www.waermepumpe.de/fileadmin/user_upload/bwp_service/SG_ready/SG_Ready_Schnittstelle_1.1.pdf
In Luxtronik these are mapped to EVU1 and EVU2
https://mw.ait-group.net/files/docs/NL/A0340/83055600.pdf
| EVU 1 | EVU 2 | Bedrijfstoestand |
| AAN (1) | UIT (O) 1 | (= EVU-blokkering)
| UIT (O) | UIT (O) | 2 (= Verlaagde werking)
| UIT (O) | AAN (1)| 3 (= Normaal bedrijf)
| AAN (1) | AAN (1) 4 (= Verhoogde werking)
The enhancement request is to provide a status entity (sensor) which mode indicates the smart grid operating status, when smart grid is enabled.