Hi,

We have received a request from a customer that was trying to calibrate CVThing with a -5/+5V Keyboard, problem is, when he configured the port to run into -5V/+5V range he was asked for 2V and 8V altough there is no way to provide 8V from a device that ranges from -5V to 5V.

As a workaround, we have told him to provide -3V when asked for 2V, and 3V when asked for 8V. That was tested in a CVThing V1.4.1 and looks like working properly (maybe a double check could be interesting).

Summarizing, it would be nice to check if the values CVThing is asking for in a port configured with range -5/+5V need to be modified from 2V and 8V to -3V and 3V, respectively.