diff --git a/ansible/group_vars/sonic/sku-sensors-data.yml b/ansible/group_vars/sonic/sku-sensors-data.yml index 1d0572c06a..9cf98738d1 100644 --- a/ansible/group_vars/sonic/sku-sensors-data.yml +++ b/ansible/group_vars/sonic/sku-sensors-data.yml @@ -6784,3 +6784,683 @@ sensors_checks: temp: [ ] psu_skips: { } sensor_skip_per_version: { } + + x86_64-arista_7280dr3a_36: + alarms: + fan: + - dps800-i2c-21-58/fan1/fan1_alarm + - dps800-i2c-21-58/fan1/fan1_fault + - dps800-i2c-21-58/fan2/fan2_alarm + - dps800-i2c-21-58/fan2/fan2_fault + - dps800-i2c-22-58/fan1/fan1_alarm + - dps800-i2c-22-58/fan1/fan1_fault + - dps800-i2c-22-58/fan2/fan2_alarm + - dps800-i2c-22-58/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan1/fan1_fault + - scd_fan_p3-pci-00c7/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan3/fan3_fault + - scd_fan_p3-pci-00c7/fan4/fan4_fault + power: + - dps800-i2c-21-58/iin/curr1_crit_alarm + - dps800-i2c-21-58/iin/curr1_max_alarm + - dps800-i2c-21-58/iout1/curr2_crit_alarm + - dps800-i2c-21-58/iout1/curr2_lcrit_alarm + - dps800-i2c-21-58/iout1/curr2_max_alarm + - dps800-i2c-21-58/pin/power1_alarm + - dps800-i2c-21-58/pout1/power2_cap_alarm + - dps800-i2c-21-58/pout1/power2_crit_alarm + - dps800-i2c-21-58/pout1/power2_max_alarm + - dps800-i2c-21-58/vin/in1_crit_alarm + - dps800-i2c-21-58/vin/in1_lcrit_alarm + - dps800-i2c-21-58/vin/in1_max_alarm + - dps800-i2c-21-58/vin/in1_min_alarm + - dps800-i2c-21-58/vout1/in3_crit_alarm + - dps800-i2c-21-58/vout1/in3_lcrit_alarm + - dps800-i2c-21-58/vout1/in3_max_alarm + - dps800-i2c-21-58/vout1/in3_min_alarm + - dps800-i2c-22-58/iin/curr1_crit_alarm + - dps800-i2c-22-58/iin/curr1_max_alarm + - dps800-i2c-22-58/iout1/curr2_crit_alarm + - dps800-i2c-22-58/iout1/curr2_lcrit_alarm + - dps800-i2c-22-58/iout1/curr2_max_alarm + - dps800-i2c-22-58/pin/power1_alarm + - dps800-i2c-22-58/pout1/power2_cap_alarm + - dps800-i2c-22-58/pout1/power2_crit_alarm + - dps800-i2c-22-58/pout1/power2_max_alarm + - dps800-i2c-22-58/vin/in1_crit_alarm + - dps800-i2c-22-58/vin/in1_lcrit_alarm + - dps800-i2c-22-58/vin/in1_max_alarm + - dps800-i2c-22-58/vin/in1_min_alarm + - dps800-i2c-22-58/vout1/in3_crit_alarm + - dps800-i2c-22-58/vout1/in3_lcrit_alarm + - dps800-i2c-22-58/vout1/in3_max_alarm + - dps800-i2c-22-58/vout1/in3_min_alarm + temp: + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_max_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_min_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_min_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_max_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_min_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_min_alarm + - max6658-i2c-9-4c/temp1/temp1_crit_alarm + - max6658-i2c-9-4c/temp1/temp1_max_alarm + - max6658-i2c-9-4c/temp1/temp1_min_alarm + - max6658-i2c-9-4c/temp2/temp2_crit_alarm + - max6658-i2c-9-4c/temp2/temp2_fault + - max6658-i2c-9-4c/temp2/temp2_max_alarm + - max6658-i2c-9-4c/temp2/temp2_min_alarm + - nvme-pci-0500/Composite/temp1_alarm + - tmp464-i2c-28-48/temp1/temp1_crit_alarm + - tmp464-i2c-28-48/temp1/temp1_max_alarm + - tmp464-i2c-28-48/temp2/temp2_crit_alarm + - tmp464-i2c-28-48/temp2/temp2_fault + - tmp464-i2c-28-48/temp2/temp2_max_alarm + - tmp464-i2c-28-48/temp3/temp3_crit_alarm + - tmp464-i2c-28-48/temp3/temp3_fault + - tmp464-i2c-28-48/temp3/temp3_max_alarm + - tmp464-i2c-28-48/temp4/temp4_crit_alarm + - tmp464-i2c-28-48/temp4/temp4_fault + - tmp464-i2c-28-48/temp4/temp4_max_alarm + - tmp464-i2c-28-48/temp5/temp5_crit_alarm + - tmp464-i2c-28-48/temp5/temp5_fault + - tmp464-i2c-28-48/temp5/temp5_max_alarm + - tmp464-i2c-28-48/temp6/temp6_crit_alarm + - tmp464-i2c-28-48/temp6/temp6_fault + - tmp464-i2c-28-48/temp6/temp6_max_alarm + - tmp464-i2c-28-48/temp7/temp7_crit_alarm + - tmp464-i2c-28-48/temp7/temp7_fault + - tmp464-i2c-28-48/temp7/temp7_max_alarm + - tmp464-i2c-28-48/temp8/temp8_crit_alarm + - tmp464-i2c-28-48/temp8/temp8_fault + - tmp464-i2c-28-48/temp8/temp8_max_alarm + - tmp464-i2c-28-48/temp9/temp9_crit_alarm + - tmp464-i2c-28-48/temp9/temp9_fault + - tmp464-i2c-28-48/temp9/temp9_max_alarm + + compares: + fan: [ ] + power: [ ] + temp: + - - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_input + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit + - - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_input + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_input + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit + - - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_input + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit + - - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_input + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_input + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit + - - max6658-i2c-9-4c/temp1/temp1_input + - max6658-i2c-9-4c/temp1/temp1_crit + - - max6658-i2c-9-4c/temp2/temp2_input + - max6658-i2c-9-4c/temp2/temp2_crit + - - nvme-pci-0500/Composite/temp1_input + - nvme-pci-0500/Composite/temp1_crit + - - tmp464-i2c-28-48/temp1/temp1_input + - tmp464-i2c-28-48/temp1/temp1_crit + - - tmp464-i2c-28-48/temp2/temp2_input + - tmp464-i2c-28-48/temp2/temp2_crit + - - tmp464-i2c-28-48/temp3/temp3_input + - tmp464-i2c-28-48/temp3/temp3_crit + - - tmp464-i2c-28-48/temp4/temp4_input + - tmp464-i2c-28-48/temp4/temp4_crit + - - tmp464-i2c-28-48/temp5/temp5_input + - tmp464-i2c-28-48/temp5/temp5_crit + + non_zero: + fan: + - dps800-i2c-21-58/fan1/fan1_input + - dps800-i2c-21-58/fan2/fan2_input + - dps800-i2c-22-58/fan1/fan1_input + - dps800-i2c-22-58/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan1/fan1_input + - scd_fan_p3-pci-00c7/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan3/fan3_input + - scd_fan_p3-pci-00c7/fan4/fan4_input + power: [ ] + temp: [ ] + + psu_skips: + dps800-i2c-21-58: + number: 1 + side: left + skip_list: + - dps800-i2c-21-58 + dps800-i2c-22-58: + number: 2 + side: right + skip_list: + - dps800-i2c-22-58 + + sensor_skip_per_version: { } + + x86_64-arista_7280dr3ak_36: + alarms: + fan: + - dps800-i2c-21-58/fan1/fan1_alarm + - dps800-i2c-21-58/fan1/fan1_fault + - dps800-i2c-21-58/fan2/fan2_alarm + - dps800-i2c-21-58/fan2/fan2_fault + - dps800-i2c-22-58/fan1/fan1_alarm + - dps800-i2c-22-58/fan1/fan1_fault + - dps800-i2c-22-58/fan2/fan2_alarm + - dps800-i2c-22-58/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan1/fan1_fault + - scd_fan_p3-pci-00c7/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan3/fan3_fault + - scd_fan_p3-pci-00c7/fan4/fan4_fault + power: + - dps800-i2c-21-58/iin/curr1_crit_alarm + - dps800-i2c-21-58/iin/curr1_max_alarm + - dps800-i2c-21-58/iout1/curr2_crit_alarm + - dps800-i2c-21-58/iout1/curr2_lcrit_alarm + - dps800-i2c-21-58/iout1/curr2_max_alarm + - dps800-i2c-21-58/pin/power1_alarm + - dps800-i2c-21-58/pout1/power2_cap_alarm + - dps800-i2c-21-58/pout1/power2_crit_alarm + - dps800-i2c-21-58/pout1/power2_max_alarm + - dps800-i2c-21-58/vin/in1_crit_alarm + - dps800-i2c-21-58/vin/in1_lcrit_alarm + - dps800-i2c-21-58/vin/in1_max_alarm + - dps800-i2c-21-58/vin/in1_min_alarm + - dps800-i2c-21-58/vout1/in3_crit_alarm + - dps800-i2c-21-58/vout1/in3_lcrit_alarm + - dps800-i2c-21-58/vout1/in3_max_alarm + - dps800-i2c-21-58/vout1/in3_min_alarm + - dps800-i2c-22-58/iin/curr1_crit_alarm + - dps800-i2c-22-58/iin/curr1_max_alarm + - dps800-i2c-22-58/iout1/curr2_crit_alarm + - dps800-i2c-22-58/iout1/curr2_lcrit_alarm + - dps800-i2c-22-58/iout1/curr2_max_alarm + - dps800-i2c-22-58/pin/power1_alarm + - dps800-i2c-22-58/pout1/power2_cap_alarm + - dps800-i2c-22-58/pout1/power2_crit_alarm + - dps800-i2c-22-58/pout1/power2_max_alarm + - dps800-i2c-22-58/vin/in1_crit_alarm + - dps800-i2c-22-58/vin/in1_lcrit_alarm + - dps800-i2c-22-58/vin/in1_max_alarm + - dps800-i2c-22-58/vin/in1_min_alarm + - dps800-i2c-22-58/vout1/in3_crit_alarm + - dps800-i2c-22-58/vout1/in3_lcrit_alarm + - dps800-i2c-22-58/vout1/in3_max_alarm + - dps800-i2c-22-58/vout1/in3_min_alarm + temp: + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_max_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_min_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_min_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_max_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_min_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_min_alarm + - max6658-i2c-9-4c/temp1/temp1_crit_alarm + - max6658-i2c-9-4c/temp1/temp1_max_alarm + - max6658-i2c-9-4c/temp1/temp1_min_alarm + - max6658-i2c-9-4c/temp2/temp2_crit_alarm + - max6658-i2c-9-4c/temp2/temp2_fault + - max6658-i2c-9-4c/temp2/temp2_max_alarm + - max6658-i2c-9-4c/temp2/temp2_min_alarm + - nvme-pci-0500/Composite/temp1_alarm + - tmp464-i2c-28-48/temp1/temp1_crit_alarm + - tmp464-i2c-28-48/temp1/temp1_max_alarm + - tmp464-i2c-28-48/temp2/temp2_crit_alarm + - tmp464-i2c-28-48/temp2/temp2_fault + - tmp464-i2c-28-48/temp2/temp2_max_alarm + - tmp464-i2c-28-48/temp3/temp3_crit_alarm + - tmp464-i2c-28-48/temp3/temp3_fault + - tmp464-i2c-28-48/temp3/temp3_max_alarm + - tmp464-i2c-28-48/temp4/temp4_crit_alarm + - tmp464-i2c-28-48/temp4/temp4_fault + - tmp464-i2c-28-48/temp4/temp4_max_alarm + - tmp464-i2c-28-48/temp5/temp5_crit_alarm + - tmp464-i2c-28-48/temp5/temp5_fault + - tmp464-i2c-28-48/temp5/temp5_max_alarm + - tmp464-i2c-28-48/temp6/temp6_crit_alarm + - tmp464-i2c-28-48/temp6/temp6_fault + - tmp464-i2c-28-48/temp6/temp6_max_alarm + - tmp464-i2c-28-48/temp7/temp7_crit_alarm + - tmp464-i2c-28-48/temp7/temp7_fault + - tmp464-i2c-28-48/temp7/temp7_max_alarm + - tmp464-i2c-28-48/temp8/temp8_crit_alarm + - tmp464-i2c-28-48/temp8/temp8_fault + - tmp464-i2c-28-48/temp8/temp8_max_alarm + - tmp464-i2c-28-48/temp9/temp9_crit_alarm + - tmp464-i2c-28-48/temp9/temp9_fault + - tmp464-i2c-28-48/temp9/temp9_max_alarm + + compares: + fan: [ ] + power: [ ] + temp: + - - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_input + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit + - - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_input + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_input + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit + - - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_input + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit + - - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_input + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_input + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit + - - max6658-i2c-9-4c/temp1/temp1_input + - max6658-i2c-9-4c/temp1/temp1_crit + - - max6658-i2c-9-4c/temp2/temp2_input + - max6658-i2c-9-4c/temp2/temp2_crit + - - nvme-pci-0500/Composite/temp1_input + - nvme-pci-0500/Composite/temp1_crit + - - tmp464-i2c-28-48/temp1/temp1_input + - tmp464-i2c-28-48/temp1/temp1_crit + - - tmp464-i2c-28-48/temp2/temp2_input + - tmp464-i2c-28-48/temp2/temp2_crit + - - tmp464-i2c-28-48/temp3/temp3_input + - tmp464-i2c-28-48/temp3/temp3_crit + - - tmp464-i2c-28-48/temp4/temp4_input + - tmp464-i2c-28-48/temp4/temp4_crit + - - tmp464-i2c-28-48/temp5/temp5_input + - tmp464-i2c-28-48/temp5/temp5_crit + + non_zero: + fan: + - dps800-i2c-21-58/fan1/fan1_input + - dps800-i2c-21-58/fan2/fan2_input + - dps800-i2c-22-58/fan1/fan1_input + - dps800-i2c-22-58/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan1/fan1_input + - scd_fan_p3-pci-00c7/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan3/fan3_input + - scd_fan_p3-pci-00c7/fan4/fan4_input + power: [ ] + temp: [ ] + + psu_skips: + dps800-i2c-21-58: + number: 1 + side: left + skip_list: + - dps800-i2c-21-58 + dps800-i2c-22-58: + number: 2 + side: right + skip_list: + - dps800-i2c-22-58 + + sensor_skip_per_version: { } + + x86_64-arista_7280dr3ak_36s: + alarms: + fan: + - dps800-i2c-21-58/fan1/fan1_alarm + - dps800-i2c-21-58/fan1/fan1_fault + - dps800-i2c-21-58/fan2/fan2_alarm + - dps800-i2c-21-58/fan2/fan2_fault + - dps800-i2c-22-58/fan1/fan1_alarm + - dps800-i2c-22-58/fan1/fan1_fault + - dps800-i2c-22-58/fan2/fan2_alarm + - dps800-i2c-22-58/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan1/fan1_fault + - scd_fan_p3-pci-00c7/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan3/fan3_fault + - scd_fan_p3-pci-00c7/fan4/fan4_fault + power: + - dps800-i2c-21-58/iin/curr1_crit_alarm + - dps800-i2c-21-58/iin/curr1_max_alarm + - dps800-i2c-21-58/iout1/curr2_crit_alarm + - dps800-i2c-21-58/iout1/curr2_lcrit_alarm + - dps800-i2c-21-58/iout1/curr2_max_alarm + - dps800-i2c-21-58/pin/power1_alarm + - dps800-i2c-21-58/pout1/power2_cap_alarm + - dps800-i2c-21-58/pout1/power2_crit_alarm + - dps800-i2c-21-58/pout1/power2_max_alarm + - dps800-i2c-21-58/vin/in1_crit_alarm + - dps800-i2c-21-58/vin/in1_lcrit_alarm + - dps800-i2c-21-58/vin/in1_max_alarm + - dps800-i2c-21-58/vin/in1_min_alarm + - dps800-i2c-21-58/vout1/in3_crit_alarm + - dps800-i2c-21-58/vout1/in3_lcrit_alarm + - dps800-i2c-21-58/vout1/in3_max_alarm + - dps800-i2c-21-58/vout1/in3_min_alarm + - dps800-i2c-22-58/iin/curr1_crit_alarm + - dps800-i2c-22-58/iin/curr1_max_alarm + - dps800-i2c-22-58/iout1/curr2_crit_alarm + - dps800-i2c-22-58/iout1/curr2_lcrit_alarm + - dps800-i2c-22-58/iout1/curr2_max_alarm + - dps800-i2c-22-58/pin/power1_alarm + - dps800-i2c-22-58/pout1/power2_cap_alarm + - dps800-i2c-22-58/pout1/power2_crit_alarm + - dps800-i2c-22-58/pout1/power2_max_alarm + - dps800-i2c-22-58/vin/in1_crit_alarm + - dps800-i2c-22-58/vin/in1_lcrit_alarm + - dps800-i2c-22-58/vin/in1_max_alarm + - dps800-i2c-22-58/vin/in1_min_alarm + - dps800-i2c-22-58/vout1/in3_crit_alarm + - dps800-i2c-22-58/vout1/in3_lcrit_alarm + - dps800-i2c-22-58/vout1/in3_max_alarm + - dps800-i2c-22-58/vout1/in3_min_alarm + temp: + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_max_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_min_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_min_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_max_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_min_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_min_alarm + - max6658-i2c-9-4c/temp1/temp1_crit_alarm + - max6658-i2c-9-4c/temp1/temp1_max_alarm + - max6658-i2c-9-4c/temp1/temp1_min_alarm + - max6658-i2c-9-4c/temp2/temp2_crit_alarm + - max6658-i2c-9-4c/temp2/temp2_fault + - max6658-i2c-9-4c/temp2/temp2_max_alarm + - max6658-i2c-9-4c/temp2/temp2_min_alarm + - nvme-pci-0500/Composite/temp1_alarm + - tmp464-i2c-28-48/temp1/temp1_crit_alarm + - tmp464-i2c-28-48/temp1/temp1_max_alarm + - tmp464-i2c-28-48/temp2/temp2_crit_alarm + - tmp464-i2c-28-48/temp2/temp2_fault + - tmp464-i2c-28-48/temp2/temp2_max_alarm + - tmp464-i2c-28-48/temp3/temp3_crit_alarm + - tmp464-i2c-28-48/temp3/temp3_fault + - tmp464-i2c-28-48/temp3/temp3_max_alarm + - tmp464-i2c-28-48/temp4/temp4_crit_alarm + - tmp464-i2c-28-48/temp4/temp4_fault + - tmp464-i2c-28-48/temp4/temp4_max_alarm + - tmp464-i2c-28-48/temp5/temp5_crit_alarm + - tmp464-i2c-28-48/temp5/temp5_fault + - tmp464-i2c-28-48/temp5/temp5_max_alarm + - tmp464-i2c-28-48/temp6/temp6_crit_alarm + - tmp464-i2c-28-48/temp6/temp6_fault + - tmp464-i2c-28-48/temp6/temp6_max_alarm + - tmp464-i2c-28-48/temp7/temp7_crit_alarm + - tmp464-i2c-28-48/temp7/temp7_fault + - tmp464-i2c-28-48/temp7/temp7_max_alarm + - tmp464-i2c-28-48/temp8/temp8_crit_alarm + - tmp464-i2c-28-48/temp8/temp8_fault + - tmp464-i2c-28-48/temp8/temp8_max_alarm + - tmp464-i2c-28-48/temp9/temp9_crit_alarm + - tmp464-i2c-28-48/temp9/temp9_fault + - tmp464-i2c-28-48/temp9/temp9_max_alarm + + compares: + fan: [ ] + power: [ ] + temp: + - - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_input + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit + - - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_input + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_input + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit + - - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_input + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit + - - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_input + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_input + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit + - - max6658-i2c-9-4c/temp1/temp1_input + - max6658-i2c-9-4c/temp1/temp1_crit + - - max6658-i2c-9-4c/temp2/temp2_input + - max6658-i2c-9-4c/temp2/temp2_crit + - - nvme-pci-0500/Composite/temp1_input + - nvme-pci-0500/Composite/temp1_crit + - - tmp464-i2c-28-48/temp1/temp1_input + - tmp464-i2c-28-48/temp1/temp1_crit + - - tmp464-i2c-28-48/temp2/temp2_input + - tmp464-i2c-28-48/temp2/temp2_crit + - - tmp464-i2c-28-48/temp3/temp3_input + - tmp464-i2c-28-48/temp3/temp3_crit + - - tmp464-i2c-28-48/temp4/temp4_input + - tmp464-i2c-28-48/temp4/temp4_crit + - - tmp464-i2c-28-48/temp5/temp5_input + - tmp464-i2c-28-48/temp5/temp5_crit + + non_zero: + fan: + - dps800-i2c-21-58/fan1/fan1_input + - dps800-i2c-21-58/fan2/fan2_input + - dps800-i2c-22-58/fan1/fan1_input + - dps800-i2c-22-58/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan1/fan1_input + - scd_fan_p3-pci-00c7/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan3/fan3_input + - scd_fan_p3-pci-00c7/fan4/fan4_input + power: [ ] + temp: [ ] + + psu_skips: + dps800-i2c-21-58: + number: 1 + side: left + skip_list: + - dps800-i2c-21-58 + dps800-i2c-22-58: + number: 2 + side: right + skip_list: + - dps800-i2c-22-58 + + sensor_skip_per_version: { } + + x86_64-arista_7280dr3am_36: + alarms: + fan: + - dps800-i2c-21-58/fan1/fan1_alarm + - dps800-i2c-21-58/fan1/fan1_fault + - dps800-i2c-21-58/fan2/fan2_alarm + - dps800-i2c-21-58/fan2/fan2_fault + - dps800-i2c-22-58/fan1/fan1_alarm + - dps800-i2c-22-58/fan1/fan1_fault + - dps800-i2c-22-58/fan2/fan2_alarm + - dps800-i2c-22-58/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan1/fan1_fault + - scd_fan_p3-pci-00c7/fan2/fan2_fault + - scd_fan_p3-pci-00c7/fan3/fan3_fault + - scd_fan_p3-pci-00c7/fan4/fan4_fault + power: + - dps800-i2c-21-58/iin/curr1_crit_alarm + - dps800-i2c-21-58/iin/curr1_max_alarm + - dps800-i2c-21-58/iout1/curr2_crit_alarm + - dps800-i2c-21-58/iout1/curr2_lcrit_alarm + - dps800-i2c-21-58/iout1/curr2_max_alarm + - dps800-i2c-21-58/pin/power1_alarm + - dps800-i2c-21-58/pout1/power2_cap_alarm + - dps800-i2c-21-58/pout1/power2_crit_alarm + - dps800-i2c-21-58/pout1/power2_max_alarm + - dps800-i2c-21-58/vin/in1_crit_alarm + - dps800-i2c-21-58/vin/in1_lcrit_alarm + - dps800-i2c-21-58/vin/in1_max_alarm + - dps800-i2c-21-58/vin/in1_min_alarm + - dps800-i2c-21-58/vout1/in3_crit_alarm + - dps800-i2c-21-58/vout1/in3_lcrit_alarm + - dps800-i2c-21-58/vout1/in3_max_alarm + - dps800-i2c-21-58/vout1/in3_min_alarm + - dps800-i2c-22-58/iin/curr1_crit_alarm + - dps800-i2c-22-58/iin/curr1_max_alarm + - dps800-i2c-22-58/iout1/curr2_crit_alarm + - dps800-i2c-22-58/iout1/curr2_lcrit_alarm + - dps800-i2c-22-58/iout1/curr2_max_alarm + - dps800-i2c-22-58/pin/power1_alarm + - dps800-i2c-22-58/pout1/power2_cap_alarm + - dps800-i2c-22-58/pout1/power2_crit_alarm + - dps800-i2c-22-58/pout1/power2_max_alarm + - dps800-i2c-22-58/vin/in1_crit_alarm + - dps800-i2c-22-58/vin/in1_lcrit_alarm + - dps800-i2c-22-58/vin/in1_max_alarm + - dps800-i2c-22-58/vin/in1_min_alarm + - dps800-i2c-22-58/vout1/in3_crit_alarm + - dps800-i2c-22-58/vout1/in3_lcrit_alarm + - dps800-i2c-22-58/vout1/in3_max_alarm + - dps800-i2c-22-58/vout1/in3_min_alarm + temp: + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_max_alarm + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_min_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_min_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_max_alarm + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_min_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_max_alarm + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_min_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_lcrit_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_max_alarm + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_min_alarm + - max6658-i2c-9-4c/temp1/temp1_crit_alarm + - max6658-i2c-9-4c/temp1/temp1_max_alarm + - max6658-i2c-9-4c/temp1/temp1_min_alarm + - max6658-i2c-9-4c/temp2/temp2_crit_alarm + - max6658-i2c-9-4c/temp2/temp2_fault + - max6658-i2c-9-4c/temp2/temp2_max_alarm + - max6658-i2c-9-4c/temp2/temp2_min_alarm + - nvme-pci-0500/Composite/temp1_alarm + - tmp464-i2c-28-48/temp1/temp1_crit_alarm + - tmp464-i2c-28-48/temp1/temp1_max_alarm + - tmp464-i2c-28-48/temp2/temp2_crit_alarm + - tmp464-i2c-28-48/temp2/temp2_fault + - tmp464-i2c-28-48/temp2/temp2_max_alarm + - tmp464-i2c-28-48/temp3/temp3_crit_alarm + - tmp464-i2c-28-48/temp3/temp3_fault + - tmp464-i2c-28-48/temp3/temp3_max_alarm + - tmp464-i2c-28-48/temp4/temp4_crit_alarm + - tmp464-i2c-28-48/temp4/temp4_fault + - tmp464-i2c-28-48/temp4/temp4_max_alarm + - tmp464-i2c-28-48/temp5/temp5_crit_alarm + - tmp464-i2c-28-48/temp5/temp5_fault + - tmp464-i2c-28-48/temp5/temp5_max_alarm + - tmp464-i2c-28-48/temp6/temp6_crit_alarm + - tmp464-i2c-28-48/temp6/temp6_fault + - tmp464-i2c-28-48/temp6/temp6_max_alarm + - tmp464-i2c-28-48/temp7/temp7_crit_alarm + - tmp464-i2c-28-48/temp7/temp7_fault + - tmp464-i2c-28-48/temp7/temp7_max_alarm + - tmp464-i2c-28-48/temp8/temp8_crit_alarm + - tmp464-i2c-28-48/temp8/temp8_fault + - tmp464-i2c-28-48/temp8/temp8_max_alarm + - tmp464-i2c-28-48/temp9/temp9_crit_alarm + - tmp464-i2c-28-48/temp9/temp9_fault + - tmp464-i2c-28-48/temp9/temp9_max_alarm + + compares: + fan: [ ] + power: [ ] + temp: + - - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_input + - dps800-i2c-21-58/Power supply 1 inlet temp sensor/temp1_crit + - - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_input + - dps800-i2c-21-58/Power supply 1 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_input + - dps800-i2c-21-58/Power supply 1 secondary hotspot sensor/temp2_crit + - - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_input + - dps800-i2c-22-58/Power supply 2 inlet temp sensor/temp1_crit + - - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_input + - dps800-i2c-22-58/Power supply 2 primary hotspot temp sensor/temp3_crit + - - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_input + - dps800-i2c-22-58/Power supply 2 secondary hotspot sensor/temp2_crit + - - max6658-i2c-9-4c/temp1/temp1_input + - max6658-i2c-9-4c/temp1/temp1_crit + - - max6658-i2c-9-4c/temp2/temp2_input + - max6658-i2c-9-4c/temp2/temp2_crit + - - nvme-pci-0500/Composite/temp1_input + - nvme-pci-0500/Composite/temp1_crit + - - tmp464-i2c-28-48/temp1/temp1_input + - tmp464-i2c-28-48/temp1/temp1_crit + - - tmp464-i2c-28-48/temp2/temp2_input + - tmp464-i2c-28-48/temp2/temp2_crit + - - tmp464-i2c-28-48/temp3/temp3_input + - tmp464-i2c-28-48/temp3/temp3_crit + - - tmp464-i2c-28-48/temp4/temp4_input + - tmp464-i2c-28-48/temp4/temp4_crit + - - tmp464-i2c-28-48/temp5/temp5_input + - tmp464-i2c-28-48/temp5/temp5_crit + + non_zero: + fan: + - dps800-i2c-21-58/fan1/fan1_input + - dps800-i2c-21-58/fan2/fan2_input + - dps800-i2c-22-58/fan1/fan1_input + - dps800-i2c-22-58/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan1/fan1_input + - scd_fan_p3-pci-00c7/fan2/fan2_input + - scd_fan_p3-pci-00c7/fan3/fan3_input + - scd_fan_p3-pci-00c7/fan4/fan4_input + power: [ ] + temp: [ ] + + psu_skips: + dps800-i2c-21-58: + number: 1 + side: left + skip_list: + - dps800-i2c-21-58 + dps800-i2c-22-58: + number: 2 + side: right + skip_list: + - dps800-i2c-22-58 + + sensor_skip_per_version: { }